Home › General › SPECIFICATIONS › 2WW BATTERY / CHARGING › from 2015.10
RM3090E _V1 General _009232 SPECIFICATIONS _0208141 2WW BATTERY / CHARGING F

SPECIFICATIONS  2WW BATTERY / CHARGING  SERVICE DATA  


Battery Standard Specific Gravity 1.25 or higher at 20°C (68°F)
Standard Voltage 12.3 V or higher at 20°C (68°F)
Fuse Standard Resistance Below 1 Ω
Charging circuit without load Standard Current 10 A or higher
Standard Voltage 12.1 to 15.4 V
Charging circuit with load Standard Current 30 A or higher

HARNESS AND CONNECTOR
Tester Connection Condition Specified Condition
B126-1 (LIN) - A58-6 (LIN1) Always Below 1 Ω
B126-1 (LIN) or A58-6 (LIN1) - Body ground Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher

GENERATOR ASSEMBLY
Generator brush holder assembly Brush length Standard exposed length 11.2 mm (0.441 in.)
Minimum exposed length 2.0 mm (0.0787 in.)