1. OPERATION CHECK
Disconnect the vacuum hose from the vacuum pump.
| *a | Vacuum Gauge |
Connect the hose of the vacuum gauge to the vacuum pump.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, check the negative pressure of the vacuum pump.
More than 87 kPa (650 mmHg, 25.6 in.Hg)
If the result is not as specified, replace the vacuum pump.
Remove the vacuum gauge from the vacuum pump.