Home › General › SPECIFICATIONS › 3ZR-FAE STARTING › from 2016.08
RM3090E _V1 General _009232 SPECIFICATIONS _0050482 3ZR-FAE STARTING F

SPECIFICATIONS  3ZR-FAE STARTING  SERVICE DATA  


STARTER ASSEMBLY
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 11.5 V 90 A or less

STARTER ASSEMBLY (w/ Stop and Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal SL2 11.5 V Below 130 A
Battery positive (+) terminal - Terminal 30 11.5 V 100 A or less

STARTER ARMATURE ASSEMBLY
Commutator for runout Maximum Runout 0.05 mm (0.00197 in.)
Commutator diameter Standard Diameter 29 mm (1.14 in.)
Minimum Diameter 28 mm (1.10 in.)
Undercut depth Standard Undercut Depth 0.7 mm (0.0276 in.)
Minimum Undercut Depth 0.4 mm (0.0157 in.)

STARTER BRUSH HOLDER ASSEMBLY
Brush length Standard Length 14.4 mm (0.567 in.)
Minimum Length 9 mm (0.354 in.)
Brush spring load Standard Spring Load 22 to 27 N (2 to 3 kgf, 4.9 to 6.1 lbf)
Minimum Spring Load 14 N (1 kgf, 3.1 lbf)