Home › Engine / Hybrid System › A25A-FKS (STARTING) › STARTING SYSTEM › 2018.10–2019.09
NM3620E _51 Engine / Hybrid System _075757 A25A-FKS STARTING _0371222 STARTING SYSTEM GE GENERAL F

A25A-FKS STARTING  STARTING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

A planetary type starter assembly is used.


b.

An Inrush Current Reduction (ICR) relay, which is built into the planetary type starter assembly, is used. The ICR relay stabilizes the vehicle power source voltage during starter motor operation.*

*: Models with stop and start system



c.

A tandem solenoid type starter assembly is used. This starter uses a structure in which the flow of current is independently supplied to the motor current solenoid and the solenoid used to push out the pinion gear. Due to this, it is possible to restart the engine when the engine has been stopped but is still moving due to inertia, thereby reducing the amount of time to restart the engine during idling stop control.*

*: Models with stop and start system



d.

A starter control (cranking hold function) is used. Once the engine switch is pushed, this function operates the starter until the engine starts.*

*: Models with entry and start system




SPECIFICATION


*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side

Model Models with Stop and Start System Models without Stop and Start System
Rating Output 1.7 kW 1.3 kW
Rating Voltage 12 V 12 V
Length*1 159.0 mm (6.25 in.) 127.4 mm (5.01 in.)
Weight 4000 g (8.8 lb) 2250 g (4.9 lb)
Rotational Direction*2 Clockwise Clockwise