Home › Engine / Hybrid System › M20A-FKS IDLING STOP CONTROL › STOP AND START
NM3620E _51 Engine / Hybrid System _075759 M20A-FKS IDLING STOP CONTROL _0371224 STOP AND START DE DETAILS F

M20A-FKS IDLING STOP CONTROL  STOP AND START  DETAILS  OIL PUMP MOTOR DRIVER  


CONSTRUCTION


a.

The oil pump motor driver is continuously controlling the oil pressure of the electric oil pump for CVT to optimal levels, which ensures smooth starting.


b.

Based on the signal (duty signal) from the engine stop and start ECU, the oil pump motor driver controls the operation of the electric oil pump for CVT and sends the pump rotation frequency to the engine stop and start ECU.

W129391E02
0.302,0.208 1.344,0.542 1.042,0.333 10 false Engine Stop and Start ECU 2.219,1.125 3.813,1.354 1.594,0.229 10 false Pump Rotation Frequency 2.083,0.635 3.99,0.813 1.906,0.177 10 false Pump Operation Power Supply 1.958,1.635 3.927,1.99 1.969,0.354 10 false Pump Operation Request Signal (Duty Signal) 4.594,2.073 6.25,2.438 1.656,0.365 10 false Electric Oil Pump for CVT 4.354,0.5 5.365,0.844 1.01,0.344 10 false Oil Pump Motor Driver