CONSTRUCTION
The camera heater (forward recognition hood with heater sub-assembly) is composed of the sheet heater (heating element) and temperature fuse, etc. Current is run through the sheet heater (heating element) to generate heat and warm the front portion of the forward recognition camera.
| *1 | Sheet Heater (Heating Element) | *2 | Temperature Fuse |
OPERATION
When all of the following conditions have been met, the camera heater (forward recognition hood with heater sub-assembly) operates.
|
*1: HV models *2: Gasoline models |
·
The power switch is turned on (IG).*1 ·
The ignition switch is turned ON.*2 ·
The ambient temperature is 10°C (50°F) or less. ·
30 seconds or more have elapsed since the camera heater (forward recognition hood with heater sub-assembly) operation stopped. |
After the camera heater (forward recognition hood with heater sub-assembly) operates, the operation will stop when a certain length of time has elapsed.
Operating time will differ based on vehicle speed, battery voltage and ambient temperature.