DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus:
for Air Conditioner: Body Electrical / Air Conditioner / Data List.
for Engine: Powertrain / Engine / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor (room temperature sensor) | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | Cooler thermistor (room temperature sensor) circuit malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction
·
When open circuit: -23.30°C (-9.94°F) ·
When short circuit: 65.95°C (150.71°F) |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F) |
Adjust ambient temperature displayed | Air conditioning amplifier assembly circuit malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Solar Sensor (D Side) | Driver side automatic light control sensor | Min.: 0
Max.: 255 |
Driver side automatic light control sensor value increases as brightness increases | Driver side automatic light control sensor circuit malfunction
·
When open circuit: 0 ·
When short circuit: 255 |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor | Min.: 0
Max.: 255 |
Front passenger side automatic light control sensor value increases as brightness increases | Front passenger side automatic light control sensor circuit malfunction
·
When open circuit: 0 ·
When short circuit: 255 |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | ·
SFI system malfunction ·
CAN communication system malfunction |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower with fan motor sub-assembly circuit malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG (gauge)
Max.: 3.2943 MPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Air Outlet Servo Pulse (R) | No. 2 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
FACE: 260 (pulse) ·
FOOT-R, D, O, F/D: 223 (pulse) ·
B/L: 212 (pulse) ·
FOOT-F: 182 (pulse) ·
D/F: 177 (pulse) ·
DEF: 158 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Air Outlet Servo Actual Pls(R) | No. 2 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
FACE: 260 (pulse) ·
FOOT-R, D, O, F/D: 223 (pulse) ·
B/L: 212 (pulse) ·
FOOT-F: 182 (pulse) ·
D/F: 177 (pulse) ·
DEF: 158 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) for RHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) for RHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) for RHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction |
| Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) for RHD:
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
S-FLOW: 278 (pulse) ·
FACE: 256 (pulse) ·
B/L: 245 (pulse) ·
FOOT-A: 224 (pulse) ·
FOOT-R (F): 215 (pulse) ·
FOOT-D: 207 (pulse) ·
F/D-R: 192 (pulse) ·
D/F: 173 (pulse) ·
DEF: 164 (pulse) for RHD:
·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R (F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction |
| Air Outlet Servo Actu Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
S-FLOW: 278 (pulse) ·
FACE: 256 (pulse) ·
B/L: 245 (pulse) ·
FOOT-A: 224 (pulse) ·
FOOT-R (F): 215 (pulse) ·
FOOT-D: 207 (pulse) ·
F/D-R: 192 (pulse) ·
D/F: 173 (pulse) ·
DEF: 164 (pulse) for RHD:
·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R (F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction |
| Air Outlet Servo Targ Pulse(P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R (F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) for RHD:
·
S-FLOW: 278 (pulse) ·
FACE: 256 (pulse) ·
B/L: 245 (pulse) ·
FOOT-A: 224 (pulse) ·
FOOT-R (F): 215 (pulse) ·
FOOT-D: 207 (pulse) ·
F/D-R: 192 (pulse) ·
D/F: 173 (pulse) ·
DEF: 164 (pulse) |
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction
(w/ Driver Seat Centralized Control) |
| Air Outlet Servo Actu Pulse(P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R (F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) for RHD:
·
S-FLOW: 278 (pulse) ·
FACE: 256 (pulse) ·
B/L: 245 (pulse) ·
FOOT-A: 224 (pulse) ·
FOOT-R (F): 215 (pulse) ·
FOOT-D: 207 (pulse) ·
F/D-R: 192 (pulse) ·
D/F: 173 (pulse) ·
DEF: 164 (pulse) |
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction
(w/ Driver Seat Centralized Control) |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
for Double Layer Type:
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) for Single Layer Type:
·
Recirculation: 258 (pulse) ·
Fresh: 235 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
for Double Layer Type:
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) for Single Layer Type:
·
Recirculation: 258 (pulse) ·
Fresh: 235 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Compressor Speed | Compressor speed | Min.: 0 rpm
Max.: 65535 rpm |
Actual compressor speed displayed | - |
| Compressor Target Speed | Compressor target speed | Min.: 0 rpm
Max.: 65535 rpm |
Compressor target speed displayed | - |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr or 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | - |
| Noise and Vibration Reduction | Function to change the speed of the compressor when set to ON | OFF or ON | Customized value displayed | - |
| ECO MODE Cancel | Function to cancel ECO mode when set to ON | OFF or ON | Customized value displayed | - |
| ECO Switch | Integration control and panel assembly (ECO switch) | OFF or ON | OFF: Integration control and panel assembly (ECO switch) not pushed
ON: Integration control and panel assembly (ECO switch) pushed and held |
Integration control and panel assembly (ECO switch) circuit malfunction |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow, Normal or Fast | Customized value displayed | Customized value displayed |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr | Customized value displayed | - |
| Compressor Drive Check | Compressor drive check | OK or NG | OK: Compressor drives
NG: Compressor does not drive |
- |
| Glass Temperature | Glass temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual glass temperature displayed | (w/ Glass Humidity Sensor) |
| Glass Surroundings Temperature | Glass surroundings temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual glass surroundings temperature displayed | (w/ Glass Humidity Sensor) |
| Glass Humidity | Glass humidity | Min.: 0.00%
Max.: 100.00% |
Actual glass humidity displayed | (w/ Glass Humidity Sensor) |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Front passenger side set temperature displayed | - |
| Operation Limitation Control History Count (Level1) | History of auxiliary battery voltage drop in the past | Min.: 0
Max.: 255 |
Number of times auxiliary battery voltage dropped in the past displayed | ·
Counted when voltage drops below the specified level due to over discharge while driving. ·
Refer to the following procedure to clear the A/C operation limitation history. |
| Operation Limitation Control History Count (Level2) | History of auxiliary battery voltage drop in the past | Min.: 0
Max.: 255 |
Number of times auxiliary battery voltage dropped in the past displayed | ·
Counted when voltage drops below the specified level due to over discharge while driving. ·
Refer to the following procedure to clear the A/C operation limitation history. |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | - |
| S-FLOW Control Auto Function | S-FLOW control auto function | ON or OFF | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
| Refrigerant High Pressure History | Refrigerant high pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure history stored displayed | * |
*: Refer to the following procedure to clear the refrigerant high pressure history.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus:
for Air Conditioner: Body Electrical / Air Conditioner / Active Test.
for Engine: Powertrain / Engine / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0
Max.: 31 |
- |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0
Max.: 7500 |
- |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 164 to 278 pulses for RHD:
Operates between 234 to 348 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
for Double Layer Type:
Operates between 220 to 256 pulses for Single Layer Type:
Operates between 235 to 258 pulses |
| Air Outlet Servo Pulse (P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 234 to 348 pulses for RHD:
Operates between 164 to 278 pulses (w/ Driver Seat Centralized Control) |
| A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 158 to 260 pulses |
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Engine Cooling Fan Duty Ratio | Electric cooling fan motor operation | 0 to 100 (%) | Perform this test when vehicle is stopped. |