If cool air is not discharged (air is discharged), the following malfunctions are possible.
| Malfunction Status | Factor |
|---|---|
| Cool air is not discharged (air is discharged) | ·
Compressor with motor assembly malfunction ·
Refrigerant pressure malfunction ·
Lack of refrigerant gas ·
Dirty cooler condenser ·
Cooling fan system malfunction ·
Air mix damper and link operation (jamming) ·
No. 1 cooler thermistor (determined as cold, conflicting with actual temperature) ·
Warm air flow |
Operate each switch on the air conditioning control assembly to check that the switch indicators are illuminated normally.
Switch indicators are illuminated normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG