Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model)
RM3620E _58 Vehicle Interior _076130 HEATING / AIR CONDITIONING _0370843 AIR CONDITIONING SYSTEM(for Gasoline Model) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Data List.


ii.

for Engine: Powertrain / Engine / Data List.



e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler thermistor (room temperature sensor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Cooler thermistor (room temperature sensor) circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


(for Automatic Air Conditioning System)
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly circuit malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Adjust ambient temperature displayed Air conditioning amplifier assembly circuit malfunction
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Solar Sensor (D Side) Driver side automatic light control sensor Min.: 0
Max.: 255
Driver side automatic light control sensor value increases as brightness increases Driver side automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


(for Automatic Air Conditioning System)
Solar Sensor (P Side) Front passenger side automatic light control sensor Min.: 0
Max.: 255
Front passenger side automatic light control sensor value increases as brightness increases Front passenger side automatic light control sensor circuit malfunction
·

When open circuit: 0

·

When short circuit: 255


(for Automatic Air Conditioning System)
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

SFI system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower with fan motor sub-assembly circuit malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG (gauge)
Max.: 3.2943 MPaG (gauge)
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation Compressor with pulley assembly circuit malfunction
Air Outlet Servo Pulse (R) No. 2 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

FACE: 260 (pulse)

·

FOOT-R, D, O, F/D: 223 (pulse)

·

B/L: 212 (pulse)

·

FOOT-F: 182 (pulse)

·

D/F: 177 (pulse)

·

DEF: 158 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Outlet Servo Actual Pls(R) No. 2 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

FACE: 260 (pulse)

·

FOOT-R, D, O, F/D: 223 (pulse)

·

B/L: 212 (pulse)

·

FOOT-F: 182 (pulse)

·

D/F: 177 (pulse)

·

DEF: 158 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction
Air Mix Servo Targ Pulse(D)
for Automatic Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse


for Manual Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


for RHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for Automatic Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction


for Manual Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (air mix) circuit malfunction


Air Mix Servo Actual Pulse(D)
for Automatic Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse


for Manual Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


for RHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for Automatic Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction


for Manual Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (air mix) circuit malfunction


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for RHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction
(for Automatic Air Conditioning System)
Air Mix Servo Actual Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


for RHD:
·

MAX COLD: 257 (pulse)

·

MAX HOT: 165 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction
(for Automatic Air Conditioning System)
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse Min.: 128
Max.: 383
·

S-FLOW: 234 (pulse)

·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-A: 288 (pulse)

·

FOOT-R (F): 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse Min.: 128
Max.: 383
·

S-FLOW: 234 (pulse)

·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT-A: 288 (pulse)

·

FOOT-R (F): 297 (pulse)

·

FOOT-D: 305 (pulse)

·

F/D-R: 320 (pulse)

·

D/F: 339 (pulse)

·

DEF: 348 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 383
for Double Layer Type:
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


for Single Layer Type:
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for Double Layer Type:
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


for Single Layer Type:
·

Recirculation: 258 (pulse)

·

Fresh: 235 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr or 2C incr Customized value displayed (for Automatic Air Conditioning System)
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed (for Automatic Air Conditioning System)
Compressor Mode Compressor mode Auto or Manual Customized value displayed (for Automatic Air Conditioning System)
Evaporator Control Evaporator control Auto or Manual Customized value displayed -
ECO MODE Cancel Function to cancel ECO mode when set to ON OFF or ON Customized value displayed -
ECO Switch Integration control and panel assembly (ECO switch) OFF or ON OFF: Integration control and panel assembly (ECO switch) not pushed
ON: Integration control and panel assembly (ECO switch) pushed and held
Integration control and panel assembly (ECO switch) circuit malfunction
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal or Fast Customized value displayed (for Automatic Air Conditioning System)
Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed (for Automatic Air Conditioning System)
Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed (for Automatic Air Conditioning System)
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr Customized value displayed (for Automatic Air Conditioning System)
A/C Cutoff Signal A/C control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed (for Automatic Air Conditioning System)
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed (for Automatic Air Conditioning System)
Operation Limitation Control History Count (Level1) History of battery voltage drop in the past Min.: 0
Max.: 255
Number of times battery voltage dropped in the past displayed
·

Counted when voltage drops below the specified level due to over discharge while driving.

·

Refer to the following procedure to clear the A/C operation limitation history.


(for Automatic Air Conditioning System)
Operation Limitation Control History Count (Level2) History of battery voltage drop in the past Min.: 0
Max.: 255
Number of times battery voltage dropped in the past displayed
·

Counted when voltage drops below the specified level due to over discharge while driving.

·

Refer to the following procedure to clear the A/C operation limitation history.


(for Automatic Air Conditioning System)
Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
S-FLOW Control Auto Function S-FLOW control auto function ON or OFF Customized value displayed (for Automatic Air Conditioning System)
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Refrigerant High Pressure History Refrigerant high pressure history Min.: 0
Max.: 255
Number of times refrigerant high pressure history stored displayed *

*: Refer to the following procedure to clear the refrigerant high pressure history.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Gasoline Model)>UTILITY


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).





ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus:

i.

for Air Conditioner: Body Electrical / Air Conditioner / Active Test.


ii.

for Engine: Powertrain / Engine / Active Test.



e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0
Max.: 31
-
Compressor Target Speed Compressor with pulley assembly Min.: 0
Max.: 7500
-
Magnetic Clutch Relay Air conditioning system operation OFF or ON -
Air Mix Servo Targ Pulse(D)
for Automatic Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse


for Manual Air Conditioning System:

No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse


Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


(for Automatic Air Conditioning System)
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse Min.: 128
Max.: 383
Operates between 234 to 348 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
for Double Layer Type:

Operates between 220 to 256 pulses


for Single Layer Type:

Operates between 235 to 258 pulses


A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 158 to 260 pulses
Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Engine Cooling Fan Duty Ratio Control the cooling fan 0 to 100% Perform this test when vehicle is stopped.