Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM (for HV Model)
RM3620E _57 Power Source / Network _076016 NETWORKING _0369864 CAN COMMUNICATION SYSTEM(for HV Model) D

NETWORKING  CAN COMMUNICATION SYSTEM(for HV Model)  UTILITY  


INITIALIZE THE CONNECTION INFORMATION OF A GATEWAY FUNCTION EQUIPPED ECU (BUS MONITOR ECU)


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Central Gateway or Main Body / Utility / Initialization.

Body Electrical > Central Gateway > Utility
Tester Display
Initialization
50005 382 207
Body Electrical > Main Body > Utility
Tester Display
Initialization
50005 123 207