Home › Power Source / Network › A25A-FKS (BATTERY / CHARGING) › CHARGING SYSTEM
RM3620E _57 Power Source / Network _076183 A25A-FKS BATTERY / CHARGING _0371282 CHARGING SYSTEM U

A25A-FKS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


B460712E17
5.49,0.917 5.823,1.156 0.333,0.24 2.01,0.917 2.385,1.156 0.375,0.24 3.885,0.927 4.26,1.167 0.375,0.24 5.531,0.958 5.99,1.156 0.458,0.198 10 false A24 2.083,0.958 2.542,1.156 0.458,0.198 10 false C40 3.958,0.969 4.417,1.167 0.458,0.198 10 false C41

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A24-1 (BATT) - A24-10 (E1) G - W-B Battery (for measuring battery voltage and for ECM memory) Always 11 to 14 V
A24-10 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
C40-62 (LIN) - Body ground B - Body ground LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher