The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during radiator assembly removal/installation are shown below.
1.DRAIN COOLANT (for Inverter)
53205
2.REMOVE UPPER RADIATOR SUPPORT SUB-ASSEMBLY
G9010A
3.REMOVE RADIATOR ASSEMBLY (for Inverter Coolant)
| *1 | No. 3 Inverter Cooling Hose |
| *2 | No. 4 Inverter Cooling Hose |
Slide the 2 hose clips and disconnect the No. 3 inverter cooling hose and No. 4 inverter cooling hose from the radiator assembly.
Remove the 4 bolts.
Detach the 2 claws and remove the radiator assembly.
Put pieces of cloth into the pipes and disconnected hoses or cover the pipes and hoses with plastic bags to prevent foreign matter from entering the radiator assembly and cooling system.
Do not apply excessive force to the No. 3 inverter cooling hose and No. 4 inverter cooling hose.