HYBRID / BATTERY CONTROL  HV RELAY ASSEMBLY(for NICKEL METAL HYDRIDE BATTERY)  INSPECTION  


PROCEDURE

Hide G92Z0 1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY

a.

Inspect SMRB:

i.

Measure the resistance according to the value(s) in the table below.

A413114C08
3.76,1.031 4.146,1.24 0.385,0.208 5.625,0.146 6.031,0.375 0.406,0.229 3.302,0.146 3.656,0.365 0.354,0.219 3.115,1.354 3.385,1.188 true 3.771,1.354 3.604,1.177 true 3.771,0.427 3.396,0.677 true 6.292,0.698 5.802,0.698 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.833,1.063 4.292,1.26 0.458,0.198 10 false M32 2.958,1.385 3.292,1.594 0.333,0.208 10 true GND 3.667,1.385 4.115,1.594 0.448,0.208 10 true SMRB 5.688,0.167 6,0.365 0.313,0.198 10 true z22 6.323,0.604 6.479,0.802 0.156,0.198 10 false + 3.333,0.156 3.646,0.354 0.313,0.198 10 true Y3 3.813,0.344 4.198,0.563 0.385,0.219 10 false CBI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z22-1 (+) - Y3-1 (CBI) Auxiliary battery voltage not applied between terminals M32-1 (SMRB) and M32-3 (GND) 10 kΩ or higher
z22-1 (+) - Y3-1 (CBI) Auxiliary battery voltage applied between terminals M32-1 (SMRB) and M32-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M32-1 (SMRB) - M32-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the HV battery junction block assembly.



b.

Inspect SMRG:

i.

Measure the resistance according to the value(s) in the table below.

A413114C09
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.021,1.354 3.292,1.188 true 3.667,1.365 3.417,1.198 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.802,1.052 4.26,1.25 0.458,0.198 10 false M32 3.552,1.406 3.885,1.615 0.333,0.208 10 true GND 2.813,1.396 3.271,1.583 0.458,0.188 10 true SMRG 2.281,0.156 2.552,0.313 0.271,0.156 10 true Y4 1.229,0.135 1.5,0.302 0.271,0.167 10 true z21 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage not applied between terminals M32-4 (SMRG) and M32-3 (GND) 10 kΩ or higher
z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage applied between terminals M32-4 (SMRG) and M32-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M32-4 (SMRG) - M32-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the HV battery junction block assembly.



c.

Inspect SMRP:

i.

Measure the resistance according to the value(s) in the table below.

A413114C10
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.115,1.354 3.385,1.188 true 3.76,1.344 3.51,1.177 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.052 4.281,1.25 0.458,0.198 10 false M32 2.958,1.385 3.292,1.594 0.333,0.208 10 true GND 3.667,1.385 4.115,1.563 0.448,0.177 10 true SMRP 2.281,0.156 2.552,0.313 0.271,0.156 10 true Y4 1.229,0.135 1.5,0.302 0.271,0.167 10 true z21 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage not applied between terminals M32-2 (SMRP) and M32-3 (GND) 10 kΩ or higher
z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage applied between terminals M32-2 (SMRP) and M32-3 (GND) 24.3 to 29.7 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M32-2 (SMRP) - M32-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω


If the result is not as specified, replace the HV battery junction block assembly.