G92Z0
1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY
Inspect SMRB:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(HV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z22-1 (+) - Y3-1 (CBI) | Auxiliary battery voltage not applied between terminals M32-1 (SMRB) and M32-3 (GND) | 10 kΩ or higher |
| z22-1 (+) - Y3-1 (CBI) | Auxiliary battery voltage applied between terminals M32-1 (SMRB) and M32-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M32-1 (SMRB) - M32-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the HV battery junction block assembly.
Inspect SMRG:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(HV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z21-1 (-) - Y4-1 (CEI) | Auxiliary battery voltage not applied between terminals M32-4 (SMRG) and M32-3 (GND) | 10 kΩ or higher |
| z21-1 (-) - Y4-1 (CEI) | Auxiliary battery voltage applied between terminals M32-4 (SMRG) and M32-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M32-4 (SMRG) - M32-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
If the result is not as specified, replace the HV battery junction block assembly.
Inspect SMRP:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(HV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z21-1 (-) - Y4-1 (CEI) | Auxiliary battery voltage not applied between terminals M32-2 (SMRP) and M32-3 (GND) | 10 kΩ or higher |
| z21-1 (-) - Y4-1 (CEI) | Auxiliary battery voltage applied between terminals M32-2 (SMRP) and M32-3 (GND) | 24.3 to 29.7 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M32-2 (SMRP) - M32-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
If the result is not as specified, replace the HV battery junction block assembly.