ENGINE STOP AND START ECU
Disconnect the engine stop and start ECU connectors.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A33-1 (BIN2) - Body ground | W - Body ground | Battery | Always | 9.5 to 14 V |
| A33-2 (GND2) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| A33-3 (BIN1) - Body ground | B - Body ground | Battery | Always | 9.5 to 14 V |
| A33-8 (GND1) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| A34-1 (+B) - Body ground | R - Body ground | Power source of engine stop and start ECU | Ignition switch ON | 9.5 to 14 V |
| A34-6 (DGND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| A34-10 (NE) - Body ground | BR - Body ground | Engine speed signal from ECM | Always | 10 kΩ or higher |
| A32*1-13 (CANH) - Body ground
G62*2-13 (CANH) - Body ground |
R - Body ground | CAN communication | Always | 200 Ω or higher |
| A32*1-14 (CANL) - Body ground
G62*2-14 (CANL) - Body ground |
W - Body ground | CAN communication | Always | 200 Ω or higher |
| A32*1-18 (IG2) - Body ground
G62*2-18 (IG2) - Body ground |
R*1 - Body ground
B*2 - Body ground |
Ignition switch signal | Ignition switch ON | 9.5 to 14 V |
| A32*1-19 (ACC) - Body ground
G62*2-19 (ACC) - Body ground |
G - Body ground | Ignition switch signal | Ignition switch ACC | 9.5 to 14 V |
| A32*1-21 (IG1) - Body ground
G62*2-21 (IG1) - Body ground |
LG - Body ground | Ignition switch signal | Ignition switch ON | 9.5 to 14 V |
Reconnect the engine stop and start ECU connectors.
Measure the resistance, voltage and pulse according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A33-6 (OP21)*3 - A34-6 (DGND) | GR - W-B | Oil pump with motor assembly drive power source signal | One of the following conditions is met:
·
Engine stopped by stop and start system control ·
Ignition switch ON (engine not running) and Active Test "Oil Pump" being performed |
10.5 to 16 V |
| A34-3 (BRE2) - Body ground | V - Body ground | Ground (vacuum sensor assembly) | Always | Below 1 Ω |
| A34-7 (BNT1) - A34-6 (DGND) | Y - W-B | Engine hood courtesy switch (hood lock assembly) signal | ·
Ignition switch ON ·
Engine stopped ·
Engine hood closed |
Below 1.5 V |
·
Ignition switch ON ·
Engine stopped ·
Engine hood open |
8 to 14 V | |||
| A34-9 (OPM1)*3 - A34-6 (DGND) | R - W-B | Oil pump with motor assembly directions signal | One of the following conditions is met:
·
Engine stopped by stop and start system control ·
Ignition switch ON (engine not running) and Active Test "Oil Pump" being performed |
Pulse generation
(See waveform 1) |
| A34-10 (NE) - A34-6 (DGND) | BR - W-B | Engine speed signal from ECM | Idling after engine warmed up | Pulse generation
(See waveform 2) |
| A34-13 (PB) - A34-3 (BRE2) | SB - V | Vacuum sensor assembly signal | ·
Ignition switch ON ·
Absolute pressure of 40 kPa (300 mmHg, 11.8 in.Hg) applied to vacuum sensor assembly |
1.6 to 2.0 V |
·
Ignition switch ON ·
Absolute pressure of 60 kPa (450 mmHg, 17.7 in.Hg) applied to vacuum sensor assembly |
2.2 to 2.6 V | |||
·
Ignition switch ON ·
Atmospheric pressure applied to vacuum sensor assembly |
3.4 to 3.8 V | |||
| A34-14 (BRVC) - A34-6 (DGND) | W - W-B | Vacuum sensor assembly power supply | ·
Ignition switch ON ·
Engine stopped |
4.5 to 5.5 V |
| A34-17 (CLL)*3 - A34-6 (DGND) | R - W-B | Park/Neutral position switch assembly signal | ·
Ignition switch ON ·
Shift lever not in P or N |
8 to 14 V |
·
Ignition switch ON ·
Shift lever in P or N |
Below 3.0 V | |||
| A34-17 (CLL)*4 - A34-6 (DGND) | R - W-B | Clutch start switch assembly signal | ·
Ignition switch ON ·
Clutch pedal released |
8 to 14 V |
·
Ignition switch ON ·
Clutch pedal fully depressed |
Below 1.5 V | |||
| A34-8 (TMN)*4 - A34-25 (TME2)*4 | L - B | Neutral position switch signal | ·
Ignition switch ON ·
Shift lever in neutral |
2.7 to 4.3 V |
·
Ignition switch ON ·
Shift lever in any other than neutral |
0.7 to 1.9 V | |||
| A34-26 (TMVC)*4 - A34-6 (DGND) | W - W-B | Neutral position switch power supply | ·
Ignition switch ON ·
Engine stopped |
4.5 to 5.5 V |
| A34-19 (DON2) - A34-6 (DGND) | L - W-B | External backup boost converter (eco run vehicle converter assembly) signal | Engine running | Pulse generation
(See Waveform 3) |
| A34-21 (STA) - A34-6 (DGND) | LG - W-B | Starter pinion operation signal | Cranking | 6.0 V or more |
| A34-23 (STA2)*3 - A34-6 (DGND) | G - W-B | Starter motor operation signal | Cranking | 6.0 V or more |
| A34-27 (NOPM)*3 - A34-6 (DGND) | LG - W-B | Oil pump with motor assembly speed signal | One of the following conditions is met:
·
Engine stopped by stop and start system control ·
Ignition switch ON (engine not running) and Active Test "Oil Pump" being performed |
Pulse generation
(See Waveform 4) |
| A32*1-1 (IG31) - A34-6 (DGND)
G62*2-1 (IG31) - A34-6 (DGND) |
LA-V - W-B | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| A32*1-2 (B41) - A34-6 (DGND)
G62*2-2 (B41) - A34-6 (DGND) |
LA-L - W-B | Backup boost converter signal | Always | 10.5 to 16 V |
| A32*1-3 (IG41) - A34-6 (DGND)
G62*2-3 (IG41) - A34-6 (DGND) |
L*1 - W-B
B*2 - W-B |
Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| A32*1-5 (ECAN) - A34-6 (DGND)
G62*2-5 (ECAN) - A34-6 (DGND) |
V*1 - W-B
B*2 - W-B |
Stop and start system cancel switch (eco run cancel switch assembly) signal | ·
Ignition switch ON ·
Stop and start system cancel switch (eco run cancel switch assembly) pressed |
Below 1.5 V |
·
Ignition switch ON ·
Stop and start system cancel switch (eco run cancel switch assembly) not pressed |
8 to 14 V | |||
| A32*1-6 (IG11) - A34-6 (DGND)
G62*2-6 (IG11) - A34-6 (DGND) |
SB - W-B | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| A32*1-10 (IG12) - A34-6 (DGND)
G62*2-10 (IG12) - A34-6 (DGND) |
W*1 - W-B
B*2 - W-B |
Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| A32*1-26 (IG13) - A34-6 (DGND)
G62*2-26 (IG13) - A34-6 (DGND) |
GR - W-B | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| A32*1-16 (B12) - A34-6 (DGND)
G62*2-16 (B12) - A34-6 (DGND) |
BR - W-B | Backup boost converter signal | Always | 10.5 to 16 V |
| A32*1-12 (B42) - A34-6 (DGND)
G62*2-12 (B42) - A34-6 (DGND) |
LA-B*1 - W-B
BE*2 - W-B |
Backup boost converter signal | Always | 10.5 to 16 V |
| A32*1-11 (B43) - A34-6 (DGND)
G62*2-11 (B43) - A34-6 (DGND) |
GR - W-B | Backup boost converter signal | Always | 10.5 to 16 V |
| A32*1-18 (IG2) - A34-6 (DGND)
G62*2-18 (IG2) - A34-6 (DGND) |
R*1 - W-B
B*2 - W-B |
Ignition switch signal | Ignition switch ACC | Below 1 V |
| Ignition switch ON | 9.5 to 14 V | |||
| A32*1-19 (ACC) - A34-6 (DGND)
G62*2-19 (ACC) - A34-6 (DGND) |
G - W-B | Ignition switch signal | Ignition switch off | Below 1 V |
| Ignition switch ACC | 9.5 to 14 V | |||
| A32*1-21 (IG1) - A34-6 (DGND)
G62*2-21 (IG1) - A34-6 (DGND) |
LG - W-B | Ignition switch signal | Ignition switch ACC | Below 1 V |
| Ignition switch ON | 9.5 to 14 V | |||
| A32*1-24 (AC41) - A34-6 (DGND)
G62*2-24 (AC41) - A34-6 (DGND) |
BE - W-B | Backup boost converter signal | Ignition switch ACC | 10.5 to 16 V |
| A32*1-25 (IL41) - A34-6 (DGND)
G62*2-25 (IL41) - A34-6 (DGND) |
Y*1 - W-B
L*2 - W-B |
Backup boost converter signal | Headlight dimmer switch (light control switch) in tail or head position | 10.5 to 16 V |
*1: for LHD
*2: for RHD
*3: for Continuously variable transaxle
*4: for Manual transaxle
Waveform 1
| Item | Content |
|---|---|
| Tester Connection | A34-9 (OPM1)*3 - A34-6 (DGND) |
| Tool Setting | 5 V/DIV., 5 ms./DIV. |
| Condition | One of the following conditions is met:
·
Engine stopped by stop and start control ·
Ignition switch ON (engine not running) and Active Test "Oil Pump" being performed |
Waveform 2
| Item | Content |
|---|---|
| Tester Connection | A34-10 (NE) - A34-6 (DGND) |
| Tool Setting | 5 V/DIV., 2 ms./DIV. |
| Condition | Idling after engine warmed up |
Waveform 3
| Item | Content |
|---|---|
| Tester Connection | A34-19 (DON2) - A34-6 (DGND) |
| Tool Setting | 5 V/DIV., 2 ms./DIV. |
| Condition | Engine running |
Waveform 4
| Item | Content |
|---|---|
| Tester Connection | A34-27 (NOPM)*3 - A34-6 (DGND) |
| Tool Setting | 5 V/DIV., 5 ms./DIV. |
| Condition | One of the following conditions is met:
·
Engine stopped by stop and start control ·