Home › Power Source / Network › A25A-FXS (BATTERY / CHARGING) › CHARGING SYSTEM
RM3620E _57 Power Source / Network _076184 A25A-FXS BATTERY / CHARGING _0372190 CHARGING SYSTEM U

A25A-FXS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECU  


CHECK HYBRID VEHICLE CONTROL ECU ASSEMBLY


C338835C20
1.25,0.104 1.667,0.365 0.417,0.26 3.271,0.104 3.688,0.365 0.417,0.26 5.313,0.104 5.729,0.365 0.417,0.26 1.24,0.438 1.656,0.698 0.417,0.26 3.271,0.438 3.688,0.698 0.417,0.26 5.313,0.438 5.729,0.698 0.417,0.26 1.344,0.146 1.802,0.344 0.458,0.198 10 false A29 3.365,0.135 3.823,0.333 0.458,0.198 10 false A31 5.406,0.146 5.865,0.344 0.458,0.198 10 false A30 1.708,0.135 2.021,0.333 0.313,0.198 10 false *A 1.344,0.5 1.802,0.698 0.458,0.198 10 false A29 3.365,0.49 3.823,0.688 0.458,0.198 10 false G64 5.406,0.49 5.865,0.688 0.458,0.198 10 false G63 1.698,0.479 2.01,0.677 0.313,0.198 10 false *B 3.75,0.146 4.063,0.344 0.313,0.198 10 false *A 5.771,0.135 6.083,0.333 0.313,0.198 10 false *A 3.75,0.479 4.063,0.677 0.313,0.198 10 false *B 5.771,0.49 6.083,0.688 0.313,0.198 10 false *B
*A for LHD *B for RHD


HINT:

The standard normal voltage between each pair of hybrid vehicle control ECU assembly terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the hybrid vehicle control ECU assembly terminal locations.


for LHD:
Terminal No. (Symbol) Wiring Color Input/Output Terminal Description Condition Specified Condition
A29-4 (HMCH) - A30-3 (E1) B - W-B Input/Output CAN communication signal Power switch on (IG) Pulse generation
(Waveform 1)
A29-5 (MREL) - A30-3 (E1) LG - W-B Output IGCT relay Power switch on (IG) 11 to 14 V
A29-8 (LIN3) - A30-3 (E1) L - W-B Input/Output LIN communication signal Power switch on (READY) Pulse generation
A29-14 (HMCL) - A30-3 (E1) W - W-B Input/Output CAN communication signal Power switch on (IG) Pulse generation
(Waveform 1)

for RHD:
Terminal No. (Symbol) Wiring Color Input/Output Terminal Description Condition Specified Condition
A29-4 (HMCH) - G63-3 (E1) B - W-B Input/Output CAN communication signal Power switch on (IG) Pulse generation
(Waveform 1)
A29-5 (MREL) - G63-3 (E1) W - W-B Output IGCT relay Power switch on (IG) 11 to 14 V
A29-8 (LIN3) - G63-3 (E1) L - W-B Input/Output LIN communication signal Power switch on (READY) Pulse generation
A29-14 (HMCL) - G63-3 (E1) W - W-B Input/Output CAN communication signal Power switch on (IG) Pulse generation
(Waveform 1)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A284438E06
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 1 (CAN communication signal)

for LHD:
Item Content
Terminal CH1: A29-4 (HMCH) - A30-3 (E1)
CH2: A29-14 (HMCL) - A30-3 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

for RHD:
Item Content
Terminal CH1: A29-4 (HMCH) - G63-3 (E1)
CH2: A29-14 (HMCL) - G63-3 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).