Home › Engine / Hybrid System › A25A-FKS (EMISSION CONTROL) › PURGE VALVE(w/o Canister Pump Module)
RM3620E _51 Engine / Hybrid System _076502 A25A-FKS EMISSION CONTROL _0372402 PURGE VALVE(w/o Canister Pump Module) G

A25A-FKS EMISSION CONTROL  PURGE VALVE(w/o Canister Pump Module)  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT PURGE VALVE (PURGE VSV)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge valve (purge VSV).


b.
A413943C01
0.302,0.813 0.604,0.813 0.604,0.813 0.792,1.281 false 1.469,1.833 1.469,1.448 true 1.396,1.833 1.594,2.021 0.198,0.188 10 false *a 0.135,0.729 0.333,0.917 0.198,0.188 10 false *b 2.219,1.906 2.417,2.104 0.198,0.198 10 false *c 2.479,0.094 2.667,0.292 0.188,0.198 10 false *d
*a Port (E)
*b Port (F)
*c Air
*d Component without harness connected
(Purge Valve (Purge VSV))


Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

OK:
Measurement Condition Specified Condition
Battery voltage applied between terminals 1 and 2 Air flows from port (F)
Battery voltage not applied between terminals 1 and 2 Air does not flow


If the result is not as specified, replace the purge valve (purge VSV).