ECM
The standard voltage and resistance between each pair of ECM terminals is shown in the table below.
The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard voltage or resistance for that pair of terminals shown in the "Specified Condition" column.
Use the illustration above as a reference for the ECM terminals.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A24-11 (CLS) - A24-20 (E2CL) | R - V | Clutch pedal stroke sensor assembly signal | Ignition switch ON, clutch pedal fully released | 0.96 to 1.04 V |
·
Ignition switch ON ·
Not depressed → Fully depressed (Clutch pedal should be operated slowly) |
Value changes progressively (Only increase) | |||
| A24-19 (VCCL) - A24-20 (E2CL) | GR - V | Power source of clutch pedal stroke sensor assembly | Ignition switch ON | 4.5 to 5.5 V |
| A24-38 (MTMS) - A24-10 (E1) | V - W-B | iMT switch (integration control and panel assembly) signal | Ignition switch ON, iMT switch (integration control and panel assembly) being pushed | Below 1.5 V |
| Ignition switch ON, iMT switch (integration control and panel assembly) not being pushed | 11 to 14 V |