This is the power source circuit for the mobile wireless charger cradle assembly.
Inspect the fuses for circuits related to this system before performing the following procedure.
| *A | w/o Light Control Rheostat |
| *a | Front view of wire harness connector
(to Mobile Wireless Charger Cradle Assembly) |
Disconnect the mobile wireless charger cradle assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*: w/o Light Control Rheostat |
||
| G13-1 (PGND) - Body ground | Always | Below 1 Ω |
| G13-8 (SDET) - Body ground* | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G13-6 (B+) - Body ground | Ignition switch off | 11 to 14 V |
| G13-5 (ACC) - Body ground | Ignition switch ACC | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG