FREEZE FRAME DATA
It is difficult to show the specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specification.
Turn the ignition switch to ON and park the vehicle on level ground. Check the freeze frame data by using the GTS.
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Check the freeze frame data on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Meter Vehicle Velocity | Vehicle speed from speedometer | Min.: 0.0 km/h (0.0 MPH)
Max.: 300.0 km/h (186.4 MPH) |
·
0.0 km/h (0.0 MPH): Engine running and vehicle stopped ·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Wheel Speed Right | Rear right wheel speed | Min.: 0.0 km/h (0.0 MPH)
Max.: 255.0 km/h (158 MPH) |
·
0.0 km/h (0.0 MPH): Engine running and vehicle stopped ·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Wheel Speed Left | Rear left wheel speed | Min.: 0.0 km/h (0.0 MPH)
Max.: 255.0 km/h (158 MPH) |
·
0.0 km/h (0.0 MPH): Engine running and vehicle stopped ·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Engine Revolution | Engine speed | Min.: 0 rpm
Max.: 12800 rpm |
No significant fluctuation | Engine running at a constant speed |
| Motor Actual Current | Amount of current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort
- The value increases when turning right and decreases when turning left |
for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Command Value Current | Requested current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort
- The value increases when turning right and decreases when turning left |
for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Steering Angle Velocity | Steering angle speed | Min.: -32768 deg/s
Max.: 32767 deg/s |
Value changes in proportion to steering speed
- The value increases when turning left and decreases when turning right |
for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Thermistor Temperature | ECU substrate temperature | Min.: -50.0°C (-58.0°F)
Max.: 150.0°C (302.0°F) |
-50.0°C to 150.0°C (-58.0°F to 302.0°F) | - |
| IG Power Supply | IG power source voltage | Min.: 0.0000 V
Max.: 20.1531 V |
8.0000 to 16.0000 V | Ignition switch ON |
| Steering Wheel Torque | Steering wheel torque | Min.: -7.00 Nm
Max.: 7.00 Nm |
Value changes in proportion to steering effort
- The value increases when turning left and decreases when turning right |
for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor Rotation Angle | Motor rotation angle | Min.: 0.000 deg
Max.: 360.0 deg |
During steering operation, motor rotation angle value changes from 0.000 to 360.0 deg | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Command Val Current 2 | Requested current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor Voltage | Motor power supply voltage | Min.: 0.000 V
Max.: 98.000 V |
9.000 to 16.000 V | Always |
| TRQ1 Zero Point Value | Zero point value of torque sensor 1 | Min.: 0.0000 V
Max.: 4.9725 V |
2.3000 to 2.7000 V | for Gasoline Model:
Engine running and steering wheel not being turned (without load) for HV Model: Hybrid control system started and steering wheel being turned (without load) |
| TRQ2 Zero Point Value | Zero point value of torque sensor 2 | Min.: 0.0000 V
Max.: 4.9725 V |
2.3000 to 2.7000 V | for Gasoline Model:
Engine running and steering wheel not being turned (without load) for HV Model: Hybrid control system started and steering wheel being turned (without load) |
| PS Assist Signal | Status of the record of power steering assist signal | OFF or ON | for Gasoline Model:
OFF: Ignition switch ON ON: Engine running for HV Model: OFF: Power switch on (IG) ON: Power switch on (READY) |
- |
| Ready Status | Ready status | Ready or OFF | Ready: Power switch on (READY)
OFF: Except power switch on (READY) |
for HV Model |
| Motor Actual Current 2 | Amount of current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Stop&Start Ctrl Mode | Stop and start system condition | IG or Run or Stopreq or Stop or Restart | - | w/ Stop and Start System |
| Steering Angle | Steering angle | Min.: -3072.0 deg
Max.: 3070.5 deg |
- | - |
| Torque Sensor 1 Output | Torque sensor 1 output value | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Torque Sensor 2 Output | Torque sensor 2 output value | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Torque Sensor 1 Power Supply | Torque sensor 1 power supply voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Torque Sensor 2 Power Supply | Torque sensor 2 power supply voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 1 | Rotation angle sensor Vx1 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 2 | Rotation angle sensor Vx2 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 3 | Rotation angle sensor Vy1 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 4 | Rotation angle sensor Vy2 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Motor 1 Terminal Current (U) | Motor 1 terminal current (U phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 1 Terminal Current (V) | Motor 1 terminal current (V phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 1 Terminal Current (W) | Motor 1 terminal current (W phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 Terminal Current (U) | Motor 2 terminal current (U phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 Terminal Current (V) | Motor 2 terminal current (V phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 Terminal Current (W) | Motor 2 terminal current (W phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 1 U Phase Duty | Motor 1 U phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 1 V Phase Duty | Motor 1 V phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 1 W Phase Duty | Motor 1 W phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 2 U Phase Duty | Motor 2 U phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 2 V Phase Duty | Motor 2 V phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 2 W Phase Duty | Motor 2 W phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 1 Terminal Volt (U) | Motor 1 terminal voltage (U phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4.000 to 35.000 V range | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 1 Terminal Volt (V) | Motor 1 terminal voltage (V phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4.000 to 35.000 V range | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 1 Terminal Volt (W) | Motor 1 terminal voltage (W phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4.000 to 35.000 V range | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 Terminal Volt (U) | Motor 2 terminal voltage (U phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4.000 to 35.000 V range | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 Terminal Volt (V) | Motor 2 terminal voltage (V phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4.000 to 35.000 V range | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 Terminal Volt (W) | Motor 2 terminal voltage (W phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4.000 to 35.000 V range | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 1 PIG Power Supply | Power supply voltage to active motor 1 | Min.: 0.0000 V
Max.: 20.1531 V |
9.000 to 16.000 V | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |
| Motor 2 PIG Power Supply | Power supply voltage to active motor 2 | Min.: 0.0000 V
Max.: 20.1531 V |
9.000 to 16.000 V | for Gasoline Model:
Engine running and steering wheel being turned for HV Model: Hybrid control system started and steering wheel being turned |