Home › Engine / Hybrid System › CRUISE CONTROL › DYNAMIC RADAR CRUISE CONTROL SYSTEM (for Gasoline Model)
RM3620E _51 Engine / Hybrid System _076038 CRUISE CONTROL _0376356 DYNAMIC RADAR CRUISE CONTROL SYSTEM(for Gasoline Model) J

CRUISE CONTROL  DYNAMIC RADAR CRUISE CONTROL SYSTEM(for Gasoline Model)  Neutral Position Switch Circuit  


DESCRIPTION

The neutral position switch detects whether the shift lever is in neutral. If the shift lever is moved to neutral for a certain period of time or more, control of vehicle speed by the dynamic radar cruise control system is canceled.

WIRING DIAGRAM

C367781E09
0.958,2.094 1.271,2.292 0.313,0.198 10 false IC 2.323,1.115 2.646,1.354 0.323,0.24 10 false W1 2.26,1.99 2.708,2.198 0.448,0.208 10 false TMN 2.385,2.865 2.729,3.052 0.344,0.188 10 false F+ 2.656,1.115 2.885,1.292 0.229,0.177 10 false 1 2.656,1.99 2.885,2.167 0.229,0.177 10 false 2 2.677,2.875 2.906,3.052 0.229,0.177 10 false 3 0.75,3.49 1.219,3.677 0.469,0.188 10 false C55 0.76,3.646 2.427,3.875 1.667,0.229 10 false Neutral Position Switch 5.813,3.792 6.281,3.979 0.469,0.188 10 false C40 5.833,3.938 6.219,4.167 0.385,0.229 10 false ECM 4.875,1.104 5.104,1.281 0.229,0.177 10 false 83 4.813,1.979 5.167,2.26 0.354,0.281 10 false 106 4.875,2.865 5.104,3.042 0.229,0.177 10 false 60 5.146,1.219 5.688,1.427 0.542,0.208 10 false VCNP 5.156,2.094 5.698,2.302 0.542,0.208 10 false NPSW 5.146,2.979 5.688,3.188 0.542,0.208 10 false ENPS

CAUTION / NOTICE / HINT

NOTICE:

Before replacing the ECM, refer to Service Bulletin.


PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine / Data List


e.

Read the Data List according to the display on the GTS.

Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Neutral Position Switch Neutral position switch status ON or OFF ON: Shift lever in neutral
OFF: Shift lever is in any position other than neutral
-
Powertrain > Engine > Data List
Tester Display
Neutral Position Switch
50003 372 881
OK:

The value of the Data List item changes in accordance with the operation of the shift lever.



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (ECM - NEUTRAL POSITION SWITCH)
2.CHECK HARNESS AND CONNECTOR (ECM - NEUTRAL POSITION SWITCH)
a.

Disconnect the C40 ECM connector.


b.

Disconnect the C55 neutral position switch connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C40-83 (VCNP) - C55-1 (W1) Always Below 1 Ω
C40-106 (NPSW) - C55-2 (TMN) Always Below 1 Ω
C40-60 (ENPS) - C55-3 (F+) Always Below 1 Ω
C40-83 (VCNP) or C55-1 (W1) - Other terminals and body ground Always 10 kΩ or higher
C40-106 (NPSW) or C55-2 (TMN) - Other terminals and body ground Always 10 kΩ or higher
C40-60 (ENPS) or C55-3 (F+) - Other terminals and body ground Always 10 kΩ or higher



d.

Connect the C55 neutral position switch connector.


e.

Connect the C40 ECM connector.


Result:
Proceed to
OK
NG



OK

3.CHECK ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK ECM
a.

Disconnect the neutral position switch connector.


b.
C367820C08
1.479,0.25 1.896,0.5 0.417,0.25 1.188,1.635 1.51,1.167 true 2.167,1.667 1.813,1.167 true 1.688,1.76 1.688,1.177 true 1,1.667 1.313,1.865 0.313,0.198 10 false W1 2.188,1.677 2.5,1.875 0.313,0.198 10 false F+ 0.208,0.156 0.521,0.354 0.313,0.198 10 false *a 1.552,0.281 2.052,0.479 0.5,0.198 10 false C55 1.552,1.771 1.938,1.99 0.385,0.219 10 false TMN
*a Front view of wire harness connector
(to Neutral Position Switch)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
C55-1 (W1) - Body ground Ignition switch ON 4.5 to 5.5 V



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C55-1 (W1) - C55-2 (TMN) Always 995 to 1005 Ω
C55-3 (F+) - Body ground Always Below 1 Ω



d.

Connect the neutral position switch connector.


Result:
Proceed to
OK
NG



OK

NG