Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL › 2018.10–2020.05
RM3620E _V1 General _077121 SPECIFICATIONS _0379403 HYBRID / BATTERY CONTROL F

SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard Value (for Brand-new Cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)
Minimum Standard Value (for Used Cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition
IGCT Relay (IGCT)
Resistance
3 - 5 10 kΩ or higher
Auxiliary battery voltage not applied between terminals 1 and 2
Below 1 Ω
Auxiliary battery voltage applied between terminals 1 and 2

HV Battery Junction Block Assembly
SMRB
Resistance
z22-1 (+) - Y3-1 (CBI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M32-1 (SMRB) and M32-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals M32-1 (SMRB) and M32-3 (GND)
M32-1 (SMRB) - M32-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
z21-1 (-) - Y4-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M32-4 (SMRG) and M32-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals M32-4 (SMRG) and M32-3 (GND)
M32-4 (SMRG) - M32-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRP
Resistance
z21-1 (-) - Y4-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M32-2 (SMRP) and M32-3 (GND)
24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals M32-2 (SMRP) and M32-3 (GND)
M32-2 (SMRP) - M32-3 (GND) 140 to 290 Ω at -40 to 80°C (-40 to 176°F)

Integration Control and Panel Assembly
Integration Control and Panel Assembly
Resistance
G32-6 (S) - G32-13 (GND) Below 1 Ω
EV mode switch (integration control and panel assembly) being pushed and held
10 kΩ or higher
EV mode switch (integration control and panel assembly) not pushed
G32-8 (B) - G32-13 (GND) Below 1 Ω
NORMAL mode switch (integration control and panel assembly) being pushed and held
10 kΩ or higher
NORMAL mode switch (integration control and panel assembly) not pushed
G32-9 (P) - G32-13 (GND) Below 1 Ω
SPORT mode switch (integration control and panel assembly) being pushed and held
10 kΩ or higher
SPORT mode switch (integration control and panel assembly) not pushed

Service Plug Grip
Tester Connection Condition Specified Condition
Service Plug Grip Always Below 1 Ω

Hybrid Battery Terminal Block
Hybrid Battery Terminal Block Always Below 1 Ω