SPECIFICATIONS M20A-FKS COOLING SERVICE DATA
COOLANT
| Item
|
Capacity
|
Classification
|
| for CVT
|
6.9 liters (7.3 US qts, 6.1 Imp. qts)
|
TOYOTA vehicles are filled with TOYOTA SLLC at the factory. In order to avoid damaging the engine cooling system and other technical problems, only use TOYOTA SLLC or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).
|
| for Manual Transaxle
|
6.4 liters (6.8 US qts, 5.6 Imp. qts)
|
THERMOSTAT
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
8.0 mm (0.315 in.) or more at 95°C (203°F)
|
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
Always
|
10.5 to 14.3 Ω
|
FLOW SHUTTING VALVE (for Heater)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
22 to 28 Ω
|
FLOW SHUTTING VALVE (for CVT)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
22 to 28 Ω
|
RADIATOR
| Item
|
Condition
|
Specified Condition
|
| Radiator cap sub-assembly
|
Standard pressure
(for brand-new radiator cap sub-assembly)
|
74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi)
|
Minimum pressure
(for used radiator cap sub-assembly)
|
59 kPa (0.6 kgf/cm2, 8.6 psi)
|