Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY)
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0374955 HYBRID CONTROL SYSTEM(for 2WD with NICKEL METAL HYDRIDE BATTERY) L

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for 2WD with NICKEL METAL HYDRIDE BATTERY)  PRECAUTION  


PRECAUTIONS FOR INSPECTING HYBRID CONTROL SYSTEM


a.
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

·

Inspecting the high-voltage system

·

Disconnecting the low voltage connector of the inverter with converter assembly

·

Disconnecting the low voltage connector of the HV battery


A406145N01
1.885,1.458 2.042,1.656 0.156,0.198 10 true 1 2.656,1.354 2.813,1.552 0.156,0.198 10 true 2 5.906,1.042 6.063,1.24 0.156,0.198 10 true 3

NOTICE:
·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

After removing the service plug grip, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY) unless instructed by the repair manual.




b.
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


c.
A358042

After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


d.
A357589C04
1.563,0.708 1.813,0.417 true 1.844,0.302 2.156,0.5 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.



e.

Check the voltage at the terminals in the inspection point in the inverter with converter assembly.

CAUTION:

Be sure to wear insulated gloves.


i.
C404069

Remove the connector cover assembly from the inverter with converter assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER (for 2WD)>REMOVAL

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




ii.
C404070

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Inspection point At least 10 minutes after removing the service plug grip 0 V


HINT:

Set the tester to DC750 V or more to measure the voltage.



iii.

Reinstall the connector cover assembly.



f.
A358019

When turning the power switch on (IG) during an inspection, do not press the power switch with the brake pedal depressed.

CAUTION:

Pressing the power switch with the brake pedal depressed causes the system to enter the READY-on state. This is very dangerous because high voltage may be applied to the inspection area.



g.

Turn the power switch off, wear insulated gloves, and disconnect the cable from the negative (-) terminal of the auxiliary battery before touching any of the orange-colored wires of the high-voltage system.

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION



h.

Turn the power switch off before performing any resistance checks.


i.

Turn the power switch off before disconnecting or reconnecting any connectors.


j.

When performing work involving high-voltage wires, use either a tool wrapped with vinyl insulation tape or an insulated tool.


k.

When high-voltage connectors are removed, wrap the connectors with insulation tape to prevent them from contacting foreign matter.



NOTICE FOR HYBRID CONTROL SYSTEM ACTIVATION


a.

When the warning is illuminated, or the auxiliary battery has been disconnected and reconnected, attempting to turn the power switch on (READY) may not start the system (the system may not enter the READY-on state) on the first attempt. If so, turn the power switch off and reattempt to start the hybrid system.

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION




PRECAUTIONS FOR DISCONNECTING AMD TERMINAL


HINT:

The AMD terminal is connected to the positive terminal of the auxiliary battery. To prevent damage when the AMD terminal is being disconnected, use the following procedure.


a.
C404071C01
0.594,2.396 0.771,0.344 0.771,0.344 0.969,0.344 true 1.802,0.792 2.063,0.792 2.063,0.792 2.417,0.479 true 1.021,0.24 1.25,0.438 0.229,0.198 10 true *1 1.542,0.688 1.76,0.885 0.219,0.198 10 true *2
*1 AMD Terminal (Inverter with Converter Assembly Side)
*2 AMD Terminal (No. 1 Engine Room Relay Block and Junction Block Assembly Side)


Be sure to disconnect the cable from the negative (-) auxiliary battery terminal before disconnecting the AMD terminal from the No. 1 engine room relay block and junction block assembly.

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION



b.

After disconnecting the AMD terminal, wrap the terminal with insulation tape.


c.

Be sure to reconnect the AMD terminal to the No. 1 engine room relay block and junction block assembly before reconnecting the cable to the negative (-) terminal of the auxiliary battery.

NOTICE:

A short circuit to ground may occur if the AMD terminal is disconnected before the cable is disconnected from the negative (-) auxiliary battery terminal. If a short circuit to ground occurs, a fusible link or fuse may break.




DISPOSING OF AN HV BATTERY


a.

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

CAUTION:
·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.

·
A358021C04
0.552,4.156 0.865,4.354 0.313,0.198 10 false *a 2.76,4.167 3.073,4.365 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned.

Therefore, make sure to return HV battery through an authorized collection agent.

·

To reduce the risk of fire, HV battery must not be stored in an area where they will be exposed to fire or high temperatures.

·

If the temperature of the HV battery is high, leave the vehicle until the temperature drops.

·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.





PRECAUTIONS WHEN REPLACING HYBRID VEHICLE CONTROL ECU ASSEMBLY


NOTICE:

Before replacing the hybrid vehicle control ECU assembly, refer to Service Bulletin.



PRECAUTIONS FOR DISCONNECTING AND RECONNECTING CABLE TO NEGATIVE (-) AUXILIARY BATTERY TERMINAL


D105639C01
0.635,0.406 0.885,0.406 0.885,0.406 1.552,0.708 false 1.885,1.313 2.458,1.031 2.458,1.031 2.656,1.031 false 0.479,0.323 0.792,0.521 0.313,0.198 10 *1 2.708,0.958 3.021,1.156 0.313,0.198 10 *2
*1 Cable
*2 Negative (-) Auxiliary Battery Terminal


a.

Before performing work on electronic components, disconnect the cable from the negative (-) auxiliary battery terminal to prevent damage to the electrical system or electrical components.


b.

Before disconnecting and reconnecting the auxiliary battery cable, turn the power switch off and the headlight switch off. Then loosen the terminal nut completely. Do not damage the cable or terminal.


c.

When the auxiliary battery cable is disconnected, the clock and radio settings and stored DTCs are cleared. Therefore, before disconnecting the auxiliary battery cable, make a note of them.

NOTICE:
·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When the cable is disconnected from the negative (-) auxiliary battery terminal, initialize the following systems after the cable is reconnected.


System Name See Procedure
Lane control System (Click here)
Parking support brake system
Pre-collision System
Parking assist monitor system
Panoramic view monitor system
Power back door system
Power door lock control system