RM3620E
_V1
General
_077121
SPECIFICATIONS
_0382575
METER / GAUGE / DISPLAY
F
SPECIFICATIONS METER / GAUGE / DISPLAY SERVICE DATA
LIGHT CONTROL RHEOSTAT
| Tester Connection
|
Condition
|
Specified Condition
|
| 4 (TR) - 2 (E)
|
Light control rheostat knob fully downwards (MIN)
|
Below 50 Ω
|
| Light control rheostat knob between MIN. and MAX
|
The value changes gradually (Between 0 to 12 kΩ)
|
| Light control rheostat knob fully upwards (MAX)
|
8 to 12 kΩ
|
| 3 (TC) - 2 (E)
|
Light control rheostat knob not fully upwards
|
Below 50 Ω
|
| Light control rheostat knob fully upwards (Tail cancel switch is on)
|
8 to 12 kΩ
|