Home › General › SPECIFICATIONS › METER / GAUGE / DISPLAY
RM3620E _V1 General _077121 SPECIFICATIONS _0382575 METER / GAUGE / DISPLAY F

SPECIFICATIONS  METER / GAUGE / DISPLAY  SERVICE DATA  


LIGHT CONTROL RHEOSTAT
Tester Connection Condition Specified Condition
4 (TR) - 2 (E) Light control rheostat knob fully downwards (MIN) Below 50 Ω
Light control rheostat knob between MIN. and MAX The value changes gradually (Between 0 to 12 kΩ)
Light control rheostat knob fully upwards (MAX) 8 to 12 kΩ
3 (TC) - 2 (E) Light control rheostat knob not fully upwards Below 50 Ω
Light control rheostat knob fully upwards (Tail cancel switch is on) 8 to 12 kΩ