Home
›
General
›
SPECIFICATIONS
›
STOP AND START
RM3620E
_V1
General
_077121
SPECIFICATIONS
_0382894
STOP AND START
F
SPECIFICATIONS STOP AND START SERVICE DATA
Eco Run Cancel Switch Assembly
Tester Connection
Switch Condition
Specified Condition
5 (ECU) - 2 (E)
Pushed
Below 1 Ω
Not pushed
10 kΩ or higher
Battery positive (+) → 6 (ILL+)
Battery negative (-) → 1 (ILL-)
-
Illuminates