SPECIFICATIONS  M20A-FKS STARTING  SERVICE DATA  


Starter Assembly (1.2 kW Type)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V Below 90 A

Magnet start switch assembly (1.2 kW Type)
Tester Connection Condition Specified Condition
Terminal 50 - Magnet starter switch assembly body Always Below 2 Ω

Starter Armature Assembly (1.2 kW Type)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher

Commutator runout Maximum runout 0.05 mm (0.00197 in.)

Commutator diameter Standard diameter 25.0 mm (0.984 in.)
Minimum diameter 24.0 mm (0.945 in.)

Undercut depth Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)

Starter Brush Holder Assembly (1.2 kW Type)
Brush length Standard length 11.6 mm (0.457 in.)
Minimum length 7.6 mm (0.299 in.)

Starter Assembly (Transaxle CVT with Stop and Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal SL2 11.5 V Below 130 A

Starter Armature Assembly (Transaxle CVT with Stop and Start System)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher

Commutator runout Maximum runout 0.05 mm (0.00197 in.)

Commutator diameter Standard diameter 29 mm (1.14 in.)
Minimum diameter 28 mm (1.10 in.)

Undercut depth Standard undercut depth 0.4 mm (0.0157 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)

Starter Brush Holder Assembly (Transaxle CVT with Stop and Start System)
Brush length Standard length 14.4 mm (0.567 in.)
Minimum length 9.0 mm (0.354 in.)

Tester Connection Condition Specified Condition
A - B
A - C
B - D
C - D
Always 10 kΩ or higher
A - D
B - C
Below 1 Ω

Standard Spring Load 22.3 to 27.3 N (2.27 to 2.78 kgf, 5.01 to 6.14 lbf)
Minimum Spring Load 13.8 N (1.41 kgf, 3.1 lbf)

Repair Service Starter Kit (Transaxle CVT with Stop and Start System)
Tester Connection Condition Specified Condition
Terminal SL1 - Magnet switch body Always Below 1 Ω
Terminal SL2 - Magnet switch body Below 2 Ω

Starter Assembly (Transaxle M/T with Stop and Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal SL1 11.5 V Below 100 A

Starter Armature Assembly (Transaxle M/T with Stop and Start System)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher

Commutator runout Maximum runout 0.05 mm (0.00197 in.)

Commutator diameter Standard diameter 29 mm (1.14 in.)
Minimum diameter 28 mm (1.10 in.)

Undercut depth Standard undercut depth 0.4 mm (0.0157 in.)
Minimum undercut depth 0.2 mm (0.00787 in.)

Starter Brush Holder Assembly (Transaxle M/T with Stop and Start System)
Brush length Standard length 14.4 mm (0.567 in.)
Minimum length 9.0 mm (0.354 in.)

Tester Connection Condition Specified Condition
A - B
A - C
B - D
C - D
Always 10 kΩ or higher
A - D
B - C
Below 1 Ω

Standard Spring Load 22.3 to 27.3 N (2.27 to 2.78 kgf, 5.01 to 6.14 lbf)
Minimum Spring Load 13.8 N (1.41 kgf, 3.1 lbf)

Magnet Starter Switch Assembly (Transaxle M/T with Stop and Start System)
Tester Connection Condition Specified Condition
Terminal SL1 - Magnet switch body Always Below 1 Ω

Engine Switch
Tester Connection Condition Specified Condition
5 (SS1) - 6 (AGND)
1 (SS2) - 6 (AGND)
Not pushed 10 kΩ or higher
Pushed Below 1 Ω

Condition Specified Condition
Battery positive (+) → Terminal 9 (SWIL)
Battery negative (-) → Terminal 6 (AGND)
Illuminates

Ignition Switch
Tester Connection Condition Specified Condition
Between all terminals LOCK 10 kΩ or higher
6 (ACC) - 7 (AM1) ACC Below 1 Ω
6 (ACC) - 7 (AM1) - 8 (IG1) ON Below 1 Ω
1 (AM2) - 2 (IG2)
5 (ST1) - 7 (AM1) - 8 (IG1) START Below 1 Ω
1 (AM2) - 2 (IG2) - 4 (ST2)

ST No. 1 Relay
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω

ST No. 2 Relay
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω