Home › General › SPECIFICATIONS › PARKING BRAKE
RM3620E _V1 General _077121 SPECIFICATIONS _0383084 PARKING BRAKE F

SPECIFICATIONS  PARKING BRAKE  SERVICE DATA  


Integration Control and Panel Assembly (Electric Parking Brake Switch (except Manual Transaxle)):

w/o Vacuum Brake Booster:

Tester Connection Condition Specified Condition
10 (LCK1) - 15 (E) OFF (Release) 95.046 to 109.354 kΩ
ON (Lock) 1.98 to 2.42 kΩ
Switch not operated 95.046 to 109.354 kΩ
21 (LCK2) -15 (E) OFF (Release) 5.394 to 6.206 kΩ
ON (Lock) 0.968 to 1.232 kΩ
Switch not operated 5.394 to 6.206 kΩ
22 (RLS1) -15 (E) OFF (Release) 0.968 to 1.232 kΩ
ON (Lock) 5.394 to 6.206 kΩ
Switch not operated 5.394 to 6.206 kΩ
23 (RLS2) -15 (E) OFF (Release) 0.968 to 1.232 kΩ
ON (Lock) 5.394 to 6.206 kΩ
Switch not operated 5.394 to 6.206 kΩ
Battery positive (+) → Terminal 12 (ILL+)
Battery negative (-) → Terminal 1 (ILL-)
- Illuminates


Integration Control and Panel Assembly (Electric Parking Brake Switch (except Manual Transaxle)):

w/ Vacuum Brake Booster:

Tester Connection Condition Specified Condition
20 (SWI1) - 21 (SWI2) OFF (Release) Below 1 Ω
ON (Lock) Below 1 Ω
Switch not operated 10 kΩ or higher
20 (SWI1) - 22 (SWO1) OFF (Release) 10 kΩ or higher
ON (Lock) Below 1 Ω
Switch not operated 10 kΩ or higher
20 (SWI1) - 23 (SWO2) OFF (Release) Below 1 Ω
ON (Lock) 10 kΩ or higher
Switch not operated Below 1 Ω
22 (SWO1) - 21 (SWI2) OFF (Release) 10 kΩ or higher
ON (Lock) Below 1 Ω
Switch not operated Below 1 Ω
22 (SWO1) - 21 (SWI2) OFF (Release) 10 kΩ or higher
ON (Lock) 10 kΩ or higher
Switch not operated 10 kΩ or higher
Battery positive (+) → Terminal 12 (ILL+)
Battery negative (-) → Terminal 1 (ILL-)
- Illuminates


Brake Warning Switch Assembly (Electric Parking Brake Switch (for Manual Transaxle)):
Tester Connection Condition Specified Condition
7 (SWI1) - 8 (SWO1) OFF (Release) 10 kΩ or higher
ON (Lock) Below 1 Ω
Switch not operated 10 kΩ or higher
7 (SWI1) - 1 (SWI2) OFF (Release) Below 1 Ω
ON (Lock) Below 1 Ω
Switch not operated 10 kΩ or higher
7 (SWI1) - 2 (SWO2) OFF (Release) Below 1 Ω
ON (Lock) 10 kΩ or higher
Switch not operated Below 1 Ω
1 (SWI2) - 8 (SWO1) OFF (Release) 10 kΩ or higher
ON (Lock) Below 1 Ω
Switch not operated Below 1 Ω
1 (SWI2) - 2 (SWO2) OFF (Release) Below 1 Ω
ON (Lock) 10 kΩ or higher
Switch not operated 10 kΩ or higher
Auxiliary battery positive (+) → 9 (ILL+)
Auxiliary battery negative (-) → 6 (ILL-)
- Illuminates