Home › Engine / Hybrid System › A25B-FXS (STARTING) › POWER SWITCH › from 2019.02
RM3620E _51 Engine / Hybrid System _080123 A25B-FXS STARTING _0388963 POWER SWITCH G

A25B-FXS STARTING  POWER SWITCH  INSPECTION  


PROCEDURE

Hide 1.INSPECT POWER SWITCH

a.

Check the resistance.

i.
A295732C10
0.76,0.906 1.208,1.073 true 2.208,1.083 2.688,0.927 true 2.219,1.344 2.698,1.573 true 1.146,1.906 1.521,1.427 true 0.052,0.042 0.365,0.198 0.313,0.156 10 *a 0.458,0.823 0.917,1.021 0.458,0.198 10 SS1 2.75,0.854 3.208,1.052 0.458,0.198 10 SS2 2.781,1.531 3.396,1.729 0.615,0.198 10 AGND 0.938,1.927 1.365,2.125 0.427,0.198 10 SWIL
*a Component without harness connected
(Power Switch)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
5 (SS1) - 6 (AGND)
1 (SS2) - 6 (AGND)
Not pushed 10 kΩ or higher
Pushed Below 1 Ω


If the result is not as specified, replace the power switch.



b.

Check the LED illumination.

i.

Apply battery voltage between the terminals of the power switch and check the illumination condition of the power switch indicator light.

OK:
Condition Specified Condition
Auxiliary battery positive (+) → Terminal 9 (SWIL)
Auxiliary battery negative (-) → Terminal 6 (AGND)
Illuminates


HINT:
·

If the positive (+) lead and the negative (-) lead are incorrectly connected, the power switch indicator light will not illuminate.

·

If the voltage is too low, the power switch indicator light will not illuminate.



If the result is not as specified, replace the power switch.