1.INSPECT CHARCOAL CANISTER ASSEMBLY
When applying vacuum, the needle may waver, but as long as the needle returns to its initial position immediately, it is not a malfunction.
Visually check the charcoal canister assembly for cracks or damage.
If cracks or damage is found, replace the charcoal canister assembly.
| *a | Port A |
| *b | Port B |
| *c | Port C |
Check the air flow.
Using a vacuum pump, check the air flow according to the procedures below.
| Measurement Condition | Specified Condition |
|---|---|
| Ports B and C closed, and vacuum applied to port A (2 kPa (15 mmHg, 0.590 in.Hg)) | No air leaks |
| Port B closed, and vacuum applied to port A (2 kPa (15 mmHg, 0.590 in.Hg)) | Air flows from port C |
| Port C closed and air blown into port A (8 kPa (0.1 kgf/cm2, 1.2 psi)) | Air flows from port B |
| Air blown into port A (8 kPa (0.1 kgf/cm2, 1.2 psi)) | Air flows from ports B and C |
If the result is not as specified, replace the charcoal canister assembly.