Home › General › SPECIFICATIONS › A25B-FXS BATTERY / CHARGING › from 2019.02
RM3620E _V1 General _077121 SPECIFICATIONS _0389729 A25B-FXS BATTERY / CHARGING F

SPECIFICATIONS  A25B-FXS BATTERY / CHARGING  SERVICE DATA  


CHARGING SYSTEM
Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off 12.0 V or higher
Auxiliary battery is OK
12.0 V or less
Recharge auxiliary battery
Recharge auxiliary battery Charge Method Normal Below 5 A
Quick Below 15 A
Fuse Standard resistance Below 1 Ω

DC/DC CONVERTER
Item Tester Connection Condition Specified Condition
Current flowing from auxiliary battery Positive (+) auxiliary battery cable Power switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
0 A or less
(No current from auxiliary battery)
Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 12.5 to 15 V