Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY) › 2019.02–2020.05
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0390716 HYBRID CONTROL SYSTEM(for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY) U

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)  TERMINALS OF ECU  


HYBRID VEHICLE CONTROL ECU ASSEMBLY


C338835C20
1.25,0.104 1.667,0.365 0.417,0.26 3.271,0.104 3.688,0.365 0.417,0.26 5.313,0.104 5.729,0.365 0.417,0.26 1.24,0.438 1.656,0.698 0.417,0.26 3.271,0.438 3.688,0.698 0.417,0.26 5.313,0.438 5.729,0.698 0.417,0.26 1.344,0.146 1.802,0.344 0.458,0.198 10 false A29 3.365,0.135 3.823,0.333 0.458,0.198 10 false A31 5.406,0.146 5.865,0.344 0.458,0.198 10 false A30 1.708,0.135 2.021,0.333 0.313,0.198 10 false *A 1.344,0.5 1.802,0.698 0.458,0.198 10 false A29 3.365,0.49 3.823,0.688 0.458,0.198 10 false G64 5.406,0.49 5.865,0.688 0.458,0.198 10 false G63 1.698,0.479 2.01,0.677 0.313,0.198 10 false *B 3.75,0.146 4.063,0.344 0.313,0.198 10 false *A 5.771,0.135 6.083,0.333 0.313,0.198 10 false *A 3.75,0.479 4.063,0.677 0.313,0.198 10 false *B 5.771,0.49 6.083,0.688 0.313,0.198 10 false *B
*A for LHD *B for RHD


for LHD:
Terminal No.
(Symbol)
Wiring Color Terminal Description Input/Output Condition Specified Condition
A29-2 (R) - A30-3 (E1) LG - W-B Shift lever position signal Input Power switch on (IG), shift lever in R 7.5 to 14 V
Power switch on (IG), shift lever not in R 0 to 1.5 V
A29-3 (DB1) - A30-3 (E1) W - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or S 7.5 to 14 V
Power switch on (IG), shift lever not in D or S 0 to 1.5 V
A29-4 (HMCH) - A30-3 (E1) B - W-B CAN Communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 2)
A29-5 (MREL) - A30-3 (E1) LG - W-B Main relay Output Power switch on (IG) 11 to 14 V
A29-6 (HSDN) - A30-3 (E1) G - W-B MG ECU shutdown signal Output Power switch on (READY) 0 to 1.5 V
A29-7 (STP) - A30-3 (E1) G - W-B Stop light switch Input Brake pedal depressed 11 to 14 V
Brake pedal released 0 to 1.5 V
A29-8 (LIN3) - A30-3 (E1) L - W-B LIN communication signal
(A/C inverter, auxiliary battery)
Input/Output Power switch on (READY) Pulse generation
A29-11 (+B1) - A30-3 (E1) R - W-B Power source Input Power switch on (IG) 11 to 14 V
A29-14 (HMCL) - A30-3 (E1) W - W-B Communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 2)
A29-15 (DB2) - A30-3 (E1) P - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or S 7.5 to 14 V
Power switch on (IG), shift lever not in D or S 0 to 1.5 V
A29-16 (PR) - A30-3 (E1) R - W-B Shift lever position signal Input Power switch on (IG), shift lever in P or R 7.5 to 14 V
Power switch on (IG), shift lever not in P or R 0 to 1.5 V
A29-18 (PSFT) - A30-3 (E1) L - W-B Shift lever position sensor power source Output Power switch on (ACC) 7.5 to 14 V
A29-20 (BL) - A30-3 (E1) LA-BE - W-B Back-up light relay Output Power switch on (IG), shift lever in R 11 to 14 V
A29-24 (VCPA) - A29-37 (EPA) R - L Accelerator pedal sensor assembly power source (for VPA) Output Power switch on (IG) 4.5 to 5.5 V
A29-26 (VCP2) - A29-25 (EPA2) SB - P Accelerator pedal sensor assembly power source (for VPA2) Output Power switch on (IG) 4.5 to 5.5 V
A29-28 (P) - A30-3 (E1) BR - W-B Shift lever position signal Input Power switch on (IG), shift lever in P 7.5 to 14 V
Power switch on (IG), shift lever not in P 0 to 1.5 V
A29-29 (N) - A30-3 (E1) G - W-B Shift lever position signal Input Power switch on (IG), shift lever in N 7.5 to 14 V
Power switch on (IG), shift lever not in N 0 to 1.5 V
A29-30 (PNB) - A30-3 (E1) B - W-B Shift lever position signal Input Power switch on (IG), shift lever in P or N 7.5 to 14 V
A29-33 (NIWP) - A30-3 (E1) W - W-B Inverter water pump assembly signal Input Power switch on (READY) Pulse generation
(Waveform 1)
A29-34 (IWP) - A30-3 (E1) L - W-B Inverter water pump assembly signal Output Power switch on (READY) Pulse generation
(Waveform 1)
A29-36 (VPA) - A29-37 (EPA) G - L Accelerator pedal sensor assembly (for accelerator pedal position detection) Input Power switch on (IG), accelerator pedal released 0.4 to 1.4 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 2.6 to 4.5 V
A29-38 (VPA2) - A29-25 (EPA2) GR - P Accelerator pedal sensor assembly (for accelerator pedal sensor malfunction detection) Input Power switch on (IG), accelerator pedal released 1.0 to 2.2 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 3.4 to 5.3 V
A29-40 (TTA) - A29-39 (ETTA) GR - W Transmission fluid temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A29-42 (RMT) - A29-43 (RMTG) L - W Rear motor temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A29-46 (MMT) - A29-45 (MMTG) Y - BE Motor temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A29-48 (GMT) - A29-47 (GMTG) G - V Generator temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A30-1 (+B2) - A30-3 (E1) BE - W-B Power source Input Power switch on (IG) 11 to 14 V
A30-4 (ST2) - A30-3 (E1) L - W-B Starter signal Input Power switch on (IG) 0 to 1.5 V
A30-7 (INDR) - A30-3 (E1) LG - W-B Shift position indicator signal Input Power switch on (IG), shift lever in R 0 to 3.2 V
Power switch on (IG), shift lever not in R 11 to 14 V
A30-8 (INDD) - A30-3 (E1) W - W-B Shift position indicator signal Input Power switch on (IG), shift lever in D 0 to 3.2 V
Power switch on (IG), shift lever not in D 11 to 14 V
A30-11 (SFTD) - A30-3 (E1) G - W-B Transmission control Input Power switch on (IG), shift lever in S 11 to 14 V
Power switch on (IG), shift lever in (-) or shift paddle switch LH (-) operated 0 to 1.5 V
A30-19 (INDP) - A30-3 (E1) B - W-B Shift position indicator signal Input Power switch on (IG), shift lever in P 0 to 3.2 V
Power switch on (IG), shift lever not in P 11 to 14 V
A30-20 (INDM) - A30-3 (E1) LA-Y - W-B Shift position indicator signal Input Power switch on (IG), shift lever in S 0 to 3.2 V
Power switch on (IG), shift lever not in S 11 to 14 V
A30-21 (INDN) - A30-3 (E1) R - W-B Shift position indicator signal Input Power switch on (IG), shift lever in N 0 to 3.2 V
Power switch on (IG), shift lever not in N 11 to 14 V
A30-24 (SFTU) - A30-3 (E1) Y - W-B Transmission control Input Power switch on (IG), shift lever in S 11 to 14 V
Power switch on (IG), shift lever in (+) or shift paddle switch RH (+) operated 0 to 1.5 V
A30-25 (M) - A30-3 (E1) LA-B - W-B Transmission control Input Power switch on (IG), shift lever in S 11 to 14 V
Power switch on (IG), shift lever not in S 0 to 1.5 V
A30-27 (BATT) - A30-3 (E1) B - W-B Constant power source Input Power switch on (IG) 11 to 14 V
Power switch on (READY) 11 to 15.5 V
A30-33 (EVSW) - A30-3 (E1) G - W-B EV mode switch (integration control and panel assembly) signal Input Power switch on (IG), EV mode switch (integration control and panel assembly) not operated 11 to 14 V
Power switch on (IG), EV mode switch (integration control and panel assembly) being pushed and held 0 to 1.5 V
A30-36 (ALSD) - A30-3 (E1) B - W-B TRAIL mode switch (integration control and panel assembly) signal Input Power switch on (IG), TRAIL mode switch (integration control and panel assembly) not operated 11 to 14 V
Power switch on (IG), TRAIL mode switch (integration control and panel assembly) being pushed and held 0 to 1.5 V
A30-37 (SPRT) - A30-3 (E1) R - W-B SPORT mode switch (integration control and panel assembly) signal Input Power switch on (IG), SPORT mode switch (integration control and panel assembly) not turned 11 to 14 V
Power switch on (IG), SPORT mode switch (integration control and panel assembly) being turned and held 0 to 1.5 V
A30-38 (NORM) ←→ A30-3 (E1) SB - W-B NORMAL mode switch (integration control and panel assembly) signal Input Power switch on (IG), NORMAL mode switch (integration control and panel assembly) not operated 11 to 14 V
Power switch on (IG), NORMAL mode switch (integration control and panel assembly) being pushed and held: 0 to 1.5 V
A30-44 (IGB) - A30-3 (E1) GR - W-B Power source Input Power switch on (IG) 11 to 14 V
A31-5 (ILK) - A30-3 (E1) V - W-B Interlock switch Input Power switch on (IG), service plug grip installed correctly 0 to 1.5 V
Power switch on (IG), service plug grip not installed 11 to 14 V
A31-7 (CA3P) - A30-3 (E1) G - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 7)
A31-8 (CA1L) - A30-3 (E1) W - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 5)
A31-13 (SMRG) - A31-12 (E01) G - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 3)
A31-15 (SMRP) - A31-12 (E01) W - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 3)
A31-16 (SMRB) - A31-12 (E01) GR - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 3)
A31-20 (CA3N) - A30-3 (E1) W - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 7)
A31-21 (CA1H) - A30-3 (E1) L - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 5)
A31-25 (PLKC) - A30-3 (E1) BE - W-B Shift lock release request signal Output Power switch on (READY), brake pedal depressed 11 to 14 V
Power switch on (READY), brake pedal released 0 to 1.5 V
A31-28 (ST1-) - A30-3 (E1) LA-G - W-B Stop light switch signal Input Power switch on (IG), brake pedal depressed 0 to 1.5 V
Power switch on (IG), brake pedal released 11 to 14 V
A31-29 (ACCI) - A30-3 (E1) P - W-B ACC relay Input Power switch on (ACC) 11 to 14 V
A31-35 (IG2) - A30-3 (E1) P - W-B Power source Input Power switch on (IG) 11 to 14 V
A31-38 (SI0) - A30-3 (E1) L - W-B Battery cooling blower operation signal Output Cooling fans operating Pulse generation
(Waveform 6)
Cooling fans not operating 4.5 to 5.5 V
A31-41 (BTH+) - A30-3 (E1) LG - W-B Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly Input Power switch on (IG) Pulse generation
(Waveform 4)
A31-42 (BTH-) - A30-3 (E1) W - W-B Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly Input Power switch on (IG) Pulse generation
(Waveform 4)

for RHD:
Terminal No.
(Symbol)
Wiring Color Terminal Description Input/Output Condition Specified Condition
A29-2 (R) - G63-3 (E1) LG - W-B Shift lever position signal Input Power switch on (IG), shift lever in R 7.5 to 14 V
Power switch on (IG), shift lever not in R 0 to 1.5 V
A29-3 (DB1) - G63-3 (E1) W - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or S 7.5 to 14 V
Power switch on (IG), shift lever not in D or S 0 to 1.5 V
A29-4 (HMCH) - G63-3 (E1) B - W-B CAN Communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 2)
A29-5 (MREL) - G63-3 (E1) W - W-B Main relay Output Power switch on (IG) 11 to 14 V
A29-6 (HSDN) - G63-3 (E1) G - W-B MG ECU shutdown signal Output Power switch on (READY) 0 to 1.5 V
A29-7 (STP) - G63-3 (E1) G - W-B Stop light switch Input Brake pedal depressed 11 to 14 V
Brake pedal released 0 to 1.5 V
A29-8 (LIN3) - G63-3 (E1) L - W-B LIN communication signal
(A/C inverter, auxiliary battery)
Input/Output Power switch on (READY) Pulse generation
A29-11 (+B1) - G63-3 (E1) R - W-B Power source Input Power switch on (IG) 11 to 14 V
A29-14 (HMCL) - G63-3 (E1) W - W-B Communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 2)
A29-15 (DB2) - G63-3 (E1) P - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or S 7.5 to 14 V
Power switch on (IG), shift lever not in D or S 0 to 1.5 V
A29-16 (PR) - G63-3 (E1) R - W-B Shift lever position signal Input Power switch on (IG), shift lever in P or R 7.5 to 14 V
Power switch on (IG), shift lever not in P or R 0 to 1.5 V
A29-18 (PSFT) - G63-3 (E1) L - W-B Shift lever position sensor power source Output Power switch on (ACC) 7.5 to 14 V
A29-20 (BL) - G63-3 (E1) LA-BE - W-B Back-up light relay Output Power switch on (IG), shift lever in R 11 to 14 V
A29-24 (VCPA) - A29-37 (EPA) R - L Accelerator pedal sensor assembly power source (for VPA) Output Power switch on (IG) 4.5 to 5.5 V
A29-26 (VCP2) - A29-25 (EPA2) SB - P Accelerator pedal sensor assembly power source (for VPA2) Output Power switch on (IG) 4.5 to 5.5 V
A29-28 (P) - G63-3 (E1) BR - W-B Shift lever position signal Input Power switch on (IG), shift lever in P 7.5 to 14 V
Power switch on (IG), shift lever not in P 0 to 1.5 V
A29-29 (N) - G63-3 (E1) G - W-B Shift lever position signal Input Power switch on (IG), shift lever in N 7.5 to 14 V
Power switch on (IG), shift lever not in N 0 to 1.5 V
A29-30 (PNB) - G63-3 (E1) B - W-B Shift lever position signal Input Power switch on (IG), shift lever in P or N 7.5 to 14 V
A29-33 (NIWP) - G63-3 (E1) W - W-B Inverter water pump assembly signal Input Power switch on (READY) Pulse generation
(Waveform 1)
A29-34 (IWP) - G63-3 (E1) L - W-B Inverter water pump assembly signal Output Power switch on (READY) Pulse generation
(Waveform 1)
A29-36 (VPA) - A29-37 (EPA) G - L Accelerator pedal sensor assembly (for accelerator pedal position detection) Input Power switch on (IG), accelerator pedal released 0.4 to 1.4 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 2.6 to 4.5 V
A29-38 (VPA2) - A29-25 (EPA2) GR - P Accelerator pedal sensor assembly (for accelerator pedal sensor malfunction detection) Input Power switch on (IG), accelerator pedal released 1.0 to 2.2 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 3.4 to 5.3 V
A29-40 (TTA) - A29-39 (ETTA) GR - W Transmission fluid temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A29-42 (RMT) - A29-43 (RMTG) L - W Rear motor temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A29-46 (MMT) - A29-45 (MMTG) Y - BE Motor temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A29-48 (GMT) - A29-47 (GMTG) P - V Generator temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
G63-1 (+B2) - G63-3 (E1) BE - W-B Power source Input Power switch on (IG) 11 to 14 V
G63-4 (ST2) - G63-3 (E1) L - W-B Starter signal Input Power switch on (IG) 0 to 1.5 V
G63-7 (INDR) - G63-3 (E1) LG - W-B Shift position indicator signal Input Power switch on (IG), shift lever in R 0 to 3.2 V
Power switch on (IG), shift lever not in R 11 to 14 V
G63-8 (INDD) - G63-3 (E1) W - W-B Shift position indicator signal Input Power switch on (IG), shift lever in D 0 to 3.2 V
Power switch on (IG), shift lever not in D 11 to 14 V
G63-11 (SFTD) - G63-3 (E1) W - W-B Transmission control Input Power switch on (IG), shift lever in S 11 to 14 V
Power switch on (IG), shift lever in (-) or shift paddle switch LH (-) operated 0 to 1.5 V
G63-19 (INDP) - G63-3 (E1) B - W-B Shift position indicator signal Input Power switch on (IG), shift lever in P 0 to 3.2 V
Power switch on (IG), shift lever not in P 11 to 14 V
G63-20 (INDM) - G63-3 (E1) LA-GR - W-B Shift position indicator signal Input Power switch on (IG), shift lever in S 0 to 3.2 V
Power switch on (IG), shift lever not in S 11 to 14 V
G63-21 (INDN) - G63-3 (E1) R - W-B Shift position indicator signal Input Power switch on (IG), shift lever in N 0 to 3.2 V
Power switch on (IG), shift lever not in N 11 to 14 V
G63-24 (SFTU) - G63-3 (E1) LG - W-B Transmission control Input Power switch on (IG), shift lever in S 11 to 14 V
Power switch on (IG), shift lever in (+) or shift paddle switch RH (+) operated 0 to 1.5 V
G63-25 (M) - G63-3 (E1) LA-B - W-B Transmission control Input Power switch on (IG), shift lever in S 11 to 14 V
Power switch on (IG), shift lever not in S 0 to 1.5 V
G63-27 (BATT) - G63-3 (E1) B - W-B Constant power source Input Always 10 to 14 V
G63-33 (EVSW) - G63-3 (E1) LA-G - W-B EV mode switch (integration control and panel assembly) signal Input Power switch on (IG), EV mode switch (integration control and panel assembly) not operated 11 to 14 V
Power switch on (IG), EV mode switch (integration control and panel assembly) being pushed and held 0 to 1.5 V
G63-36 (ALSD) - G63-3 (E1) B - W-B TRAIL mode switch (integration control and panel assembly) signal Input Power switch on (IG), TRAIL mode switch (integration control and panel assembly) not operated 11 to 14 V
Power switch on (IG), TRAIL mode switch (integration control and panel assembly) being pushed and held 0 to 1.5 V
G63-37 (SPRT) - G63-3 (E1) R - W-B SPORT mode switch (integration control and panel assembly) signal Input Power switch on (IG), SPORT mode switch (integration control and panel assembly) not turned 11 to 14 V
Power switch on (IG), SPORT mode switch (integration control and panel assembly) being turned and held 0 to 1.5 V
G63-38 (NORM) ←→ G63-3 (E1) LG - W-B NORMAL mode switch (integration control and panel assembly) signal Input Power switch on (IG), NORMAL mode switch (integration control and panel assembly) not operated 11 to 14 V
Power switch on (IG), NORMAL mode switch (integration control and panel assembly) being pushed and held: 0 to 1.5 V
G63-44 (IGB) - G63-3 (E1) GR - W-B Power source Input Power switch on (IG) 11 to 14 V
G64-5 (ILK) - G63-3 (E1) GR - W-B Interlock switch Input Power switch on (IG), service plug grip installed correctly 0 to 1.5 V
Power switch on (IG), service plug grip not installed 11 to 14 V
G64-7 (CA3P) - G63-3 (E1) G - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 7)
G64-8 (CA1L) - G63-3 (E1) W - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 5)
G64-13 (SMRG) - G64-12 (E01) LA-G - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 3)
G64-15 (SMRP) - G64-12 (E01) LA-W - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 3)
G64-16 (SMRB) - G64-12 (E01) LA-GR - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 3)
G64-20 (CA3N) - G63-3 (E1) W - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 7)
G64-21 (CA1H) - G63-3 (E1) L - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation
(Waveform 5)
G64-25 (PLKC) - G63-3 (E1) LA-BE - W-B Shift lock release request signal Output Power switch on (READY), brake pedal depressed 11 to 14 V
Power switch on (READY), brake pedal released 0 to 1.5 V
G64-28 (ST1-) - G63-3 (E1) LA-LG - W-B Stop light switch signal Input Power switch on (IG), brake pedal depressed 0 to 1.5 V
Power switch on (IG), brake pedal released 11 to 14 V
G64-29 (ACCI) - G63-3 (E1) P - W-B ACC relay Input Power switch on (ACC) 11 to 14 V
G64-35 (IG2) - G63-3 (E1) LA-B - W-B Power source Input Power switch on (IG) 11 to 14 V
G64-38 (SI0) - G63-3 (E1) L - W-B Battery cooling blower operation signal Output Cooling fans operating Pulse generation
(Waveform 6)
Cooling fans not operating 4.5 to 5.5 V
G64-41 (BTH+) - G63-3 (E1) LG - W-B Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly Input Power switch on (IG) Pulse generation
(Waveform 4)
G64-42 (BTH-) - G63-3 (E1) W - W-B Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly Input Power switch on (IG) Pulse generation
(Waveform 4)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A415999E04
0.365,0.854 0.823,1.052 0.458,0.198 10 false CH1 0.375,1.417 0.833,1.615 0.458,0.198 10 false CH2 2.958,1.635 3.281,1.917 0.323,0.281 10 false GND 2.958,0.854 3.281,1.135 0.323,0.281 10 false GND

Waveform 1 (Inverter water pump assembly signal)

Item Content
Terminal
for LHD:

CH1: A29-34 (IWP) - A30-3 (E1)

CH2: A29-33 (NIWP) - A30-3 (E1)


for RHD:

CH1: A29-34 (IWP) - G63-3 (E1)

CH2: A29-33 (NIWP) - G63-3 (E1)


Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY)

HINT:

The duty of the IWP signal and the frequency of the NIWP signal change according to the coolant (for inverter) temperature.



ii.
A284438E08
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 2 (MG ECU communication request signal)

Item Content
Terminal
for LHD:

CH1: A29-4 (HMCH) - A30-3 (E1)

CH2: A29-14 (HMCL) - A30-3 (E1)


for RHD:

CH1: A29-4 (HMCH) - G63-3 (E1)

CH2: A29-14 (HMCL) - G63-3 (E1)


Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



iii.
C206010E19
2.958,0.656 3.292,0.896 0.333,0.24 10 false GND 2.958,1.042 3.292,1.281 0.333,0.24 10 false GND 2.958,1.427 3.292,1.667 0.333,0.24 10 false GND 0.271,0.573 0.594,0.781 0.323,0.208 10 false CH1 0.281,0.948 0.615,1.188 0.333,0.24 10 false CH2 0.292,1.313 0.625,1.552 0.333,0.24 10 false CH3

Waveform 3 (System main relay operation signal)

Item Content
Terminal
for LHD:

CH1: A31-15 (SMRP) - A31-12 (E01)

CH2: A31-16 (SMRB) - A31-12 (E01)

CH3: A31-13 (SMRG) - A31-12 (E01)


for RHD:

CH1: G64-15 (SMRP) - G64-12 (E01)

CH2: G64-16 (SMRB) - G64-12 (E01)

CH3: G64-13 (SMRG) - G64-12 (E01)


Equipment Setting 10 V/DIV., 200 ms./DIV.
Condition Power switch on (IG) → Power switch on (READY)


iv.
A298837E02
0.313,0.771 0.635,0.948 0.323,0.177 10 CH1 0.323,1.354 0.646,1.531 0.323,0.177 10 CH2 2.99,1.042 3.354,1.24 0.365,0.198 10 GND 2.99,1.594 3.354,1.792 0.365,0.198 10 GND

Waveform 4 (Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly)

Item Content
Terminal
for LHD:

CH1: A31-41 (BTH+) - A30-3 (E1)

CH2: A31-42 (BTH-) - A30-3 (E1)


for RHD:

CH1: G64-41 (BTH+) - G63-3 (E1)

CH2: G64-42 (BTH-) - G63-3 (E1)


Equipment Setting 2 V/DIV., 500 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



v.
A284438E09
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 5 (CAN communication signal)

Item Content
Terminal
for LHD:

CH1: A31-21 (CA1H) - A30-3 (E1)

CH2: A31-8 (CA1L) - A30-3 (E1)


for RHD:

CH1: G64-21 (CA1H) - G63-3 (E1)

CH2: G64-8 (CA1L) - G63-3 (E1)


Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



vi.
C257882E03
2.99,1.052 3.396,1.292 0.406,0.24 10 false GND

Waveform 6 (HV battery blower fan operation signal)

Item Content
Terminal
for LHD:

A31-38 (SI0) - A30-3 (E1)


for RHD:

G64-38 (SI0) - G63-3 (E1)


Equipment Setting 10 V/DIV., 1 ms./DIV.
Condition Cooling fans operating

HINT:

The waveform will vary with the operating speed of the battery cooling blower assembly.



vii.
A284438E10
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 7 (CAN communication signal)

Item Content
Terminal
for LHD:

CH1: A31-7 (CA3P) - A30-3 (E1)

CH2: A31-20 (CA3N) - A30-3 (E1)


for RHD:

CH1: G64-7 (CA3P) - G63-3 (E1)

CH2: G64-20 (CA3N) - G63-3 (E1)


Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).





BATTERY VOLTAGE SENSOR


A368663E09
1.469,3.031 1.896,3.26 0.427,0.229 4.656,3.031 5.083,3.26 0.427,0.229 5.875,3.021 6.302,3.25 0.427,0.229 1.615,3.083 1.927,3.281 0.313,0.198 10 false c1 4.75,3.073 5.063,3.271 0.313,0.198 10 false z19 5.948,3.052 6.26,3.25 0.313,0.198 10 false N17

for LHD:
Terminal No.
(Symbol)
Wiring Color Input/Output Terminal Description Condition Specified Condition
z19-1 (TC0) - z19-7 (GC0) G - G Input Intake air temperature sensor Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-2 (TB2) - z19-8 (GB2) R - R Input Battery temperature sensor 2 Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-3 (TB1) - z19-9 (GB1) W - W Input Battery temperature sensor 1 Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-4 (TB0) - z19-10 (GB0) L - L Input Battery temperature sensor 0 Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-5 (IB0) - z19-12 (GIB) G - G Input Battery current sensor Power switch on (IG) 0.5 to 4.5 V
z19-6 (VIB) - z19-12 (GIB) G - G Output Power source for battery current sensor Power switch on (IG) 4.5 to 5.5 V
N17-1 (IGCT) - N17-5 (GND) W - LA Input Control signal Power switch on (IG) 11 to 14 V
N17-2 (BTH+) - N17-5 (GND) GR - LA Output Serial communication Power switch on (IG) Pulse generation
(waveform 1)
N17-3 (BTH-) - N17-5 (GND) W - LA Output Serial communication Power switch on (IG) Pulse generation
(waveform 2)
N17-5 (GND) - Body ground LA - Ground Always (continuity check) Below 1 Ω
N17-8 (FP0) - N17-5 (GND) B - LA Input Battery cooling blower monitor signal Cooling blower stopped 0 Hz
Cooling blower activated Pulse generation
(waveform 3)

for RHD:
Terminal No.
(Symbol)
Wiring Color Input/Output Terminal Description Condition Specified Condition
z19-1 (TC0) - z19-7 (GC0) G - G Input Intake air temperature sensor Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-2 (TB2) - z19-8 (GB2) R - R Input Battery temperature sensor 2 Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-3 (TB1) - z19-9 (GB1) W - W Input Battery temperature sensor 1 Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-4 (TB0) - z19-10 (GB0) L - L Input Battery temperature sensor 0 Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z19-5 (IB0) - z19-12 (GIB) G - G Input Battery current sensor Power switch on (IG) 0.5 to 4.5 V
z19-6 (VIB) - z19-12 (GIB) G - G Output Power source for battery current sensor Power switch on (IG) 4.5 to 5.5 V
N17-1 (IGCT) - N17-5 (GND) W - W-B Input Control signal Power switch on (IG) 11 to 14 V
N17-2 (BTH+) - N17-5 (GND) GR - W-B Output Serial communication Power switch on (IG) Pulse generation
(waveform 1)
N17-3 (BTH-) - N17-5 (GND) W - W-B Output Serial communication Power switch on (IG) Pulse generation
(waveform 2)
N17-5 (GND) - Body ground W-B - Ground Always (continuity check) Below 1 Ω
N17-8 (FP0) - N17-5 (GND) B - W-B Input Battery cooling blower monitor signal Cooling blower stopped 0 Hz
Cooling blower activated Pulse generation
(waveform 3)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A284561E08
2.99,1.219 3.396,1.417 0.406,0.198 10 GND

Waveform 1 (Serial communication)

Item Content
Terminal N17-2 (BTH+) - N17-5 (GND)
Equipment Setting 2 V/DIV., 500 μs/DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



ii.
A284562E07
2.99,1.229 3.396,1.438 0.406,0.208 10 GND

Waveform 2 (Serial communication)

Item Content
Terminal N17-3 (BTH-) - N17-5 (GND)
Equipment Setting 2 V/DIV., 500 μs/DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



iii.
A284436E07
2.938,1.031 3.396,1.229 0.458,0.198 10 false GND

Waveform 3 (Battery cooling blower monitor signal)

Item Content
Terminal N17-8 (FP0) - N17-5 (GND)
Equipment Setting 2 V/DIV., 2 ms/DIV.
Condition Battery cooling blower assembly operating (Active Test of cooling fan being performed)

HINT: