MALFUNCTION DESCRIPTION
This DTC indicates that magnetic force deterioration of the permanent magnet located in the rotor inside the generator (MG1) has been detected. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Inverter | Inverter with converter assembly internal circuit malfunction |
| Hybrid vehicle transaxle assembly | ·
Generator (MG1) internal malfunction (entry of foreign matter, etc.) ·
Generator (MG1) permanent magnet magnetic force deterioration ·
Open or short circuit in the generator coils |
| Inverter low-voltage circuit | The connectors are not connected properly |
| Motor cable (for MG1) | ·
Defective motor cable (for MG1) connection condition ·
Open circuit or poor insulation in motor cable (for MG1) |
| Hybrid vehicle control ECU assembly | Hybrid vehicle control ECU assembly internal circuit malfunction |
For a description of the generator (MG1).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A9200 | Hybrid Generator Performance | Generator magnetic force deterioration:
Decrease in the magnetic force of the generator (MG1) is detected. (1 trip detection logic) |
·
Hybrid vehicle transaxle assembly ·
Motor cable ·
Inverter with converter assembly ·
Wire harness or connector ·
Hybrid vehicle control ECU assembly |
Comes on | Master Warning:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Turn the power switch on (READY).
Drive the vehicle until the cumulative traveling time using the engine is a few minutes. (It is not necessary to drive continuously using the engine.)
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Generator High-voltage Circuit.
Refer to the wiring diagram for the Shut Down Signal Circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control, Motor Generator and Rear Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A9200 only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of motor generator control system in the tables below are output. | C |
| DTCs of rear motor generator control system in the tables below are output. | D |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| System Main Relay or High Voltage Circuit Malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P0A1B1F | Generator Control Module Circuit Intermittent | ||
| P0A1C49 | Drive Motor "B" Control Module Internal Electronic Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P1C2C1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range | ||
| P1C2C49 | Drive Motor "B" Control Module AD Converter Internal Electronic Failure | ||
| P310A83 | Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P310A86 | Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
| P310A87 | Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message | ||
| P310B83 | Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect | ||
| P310B86 | Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
| P310B87 | Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| P32BF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect | ||
| P32BF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
| P32BF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message | ||
| P32CF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect | ||
| P32CF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
| P32CF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message | ||
| Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| Sensor and actuator circuit malfunction | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
| P0A4516 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold | ||
| P0A4521 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum | ||
| P0A4522 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum | ||
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
| P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
| P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
| P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
| P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
| P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
| P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
| P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BF112 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery | ||
| P0BF114 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0BF128 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BF512 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery | ||
| P0BF514 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BF528 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BF912 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery | ||
| P0BF914 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BF928 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0BFE62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5513 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open | ||
| P0C5516 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5517 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C5F13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open | ||
| P0C5F16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5F17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | ||
| P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | ||
| P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | ||
| P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
| P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
| P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAE49 | Drive Motor "B" Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P1CB138 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect | ||
| P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure | ||
| Rear motor generator control system | P0A6912 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery | |
| P0A6914 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open | ||
| P0A691C | Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range | ||
| P0A6C12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery | ||
| P0A6C14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open | ||
| P0A6C1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range | ||
| Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure | ||
| System malfunction | Motor generator control system | P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A7973 | Drive Motor "B" Inverter Actuator Stuck Closed | ||
| P0A7A73 | Generator Inverter Actuator Stuck Closed | ||
| P0E7100 | Generator Execution Torque Performance | ||
P0A9200 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
A
B
C
D
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.
| Tester Display |
|---|
| Diagnosis Related Information |
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Read the diagnosis related information and freeze frame data of DTC P0A9200.
| Result | Proceed to |
|---|---|
| DTC P312487 is listed in Diagnosis Related Information. | A |
| DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. | B |
| Other than above | C |
Turn the power switch off.
A
B
C
Connect the GTS to the DLC3.
Clear the DTCs.
Turn the power switch on (READY) with the shift lever in P.
Turn the air conditioning system on and wait for 1 minute with the engine stopped.
If the engine starts before 1 minute has elapsed, wait until it stops and then perform this step again.
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A9200 or P1CA51D is output, or DTC is not output. | A |
| DTCs other than P0A9200 and P1CA51D are also output. | B |
Turn the power switch off.
A
B
Ensure the safety of the areas in front and at the back of the vehicle.
Apply the parking brake and secure the wheels using chocks.
Perform this test with the AUTO function (shift-linked function) of the electric parking brake system off.
When the parking brake indicator (red) is illuminated after the electric parking brake switch assembly has been pulled to the lock side, the maximum amount of braking force is applied if the electric parking brake switch assembly is pulled to the lock side one more time.
Connect the GTS to the DLC3.
Clear the DTCs.
Turn the power switch on (READY).
Depress the brake pedal firmly with your left foot.
Move the shift lever to D.
Depress the brake pedal firmly with your left foot and fully depress the accelerator pedal for 5 seconds, and then release it.
Make sure to fully apply the parking brake and firmly depress the brake pedal to prevent the vehicle from moving.
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A9200 or P1CA51D is output, or DTC is not output. | A |
| DTCs other than P0A9200 and P1CA51D are also output. | B |
Turn the power switch off.
A
B
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.
| Proceed to |
|---|
| NEXT |
NEXT