HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)  P0A949E  DC/DC Converter Stuck On  P0D3319  DC/DC Converter Circuit Current Above Threshold  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC indicates that a large current flowed in the boost converter. The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Hybrid vehicle transaxle assembly
·

Open or short circuit in the motor or generator coils

·

Motor (MG2) or generator (MG1) internal malfunction (iron particles or damage from foreign objects)


Resolver Open or short circuit in the motor resolver or generator resolver
Inverter
·

Inverter internal circuit malfunction

·

Malfunction in ECU that controls the inverter

·

Malfunction in sensor for inverter control (current sensor, VH sensor, VL sensor)


Inverter cooling system
·

Inverter water pump assembly malfunction

·

Coolant leak

·

Frozen

·

Blockage




DESCRIPTION

For a description of the boost converter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>P0CA300

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A949E DC/DC Converter Stuck On Boost converter fail signal detected (circuit malfunction)
(1 trip detection logic)
·

Inverter cooling system

·

Cooling fan system

·

Grille shutter system*

·

Wire harness or connector

·

Motor cable

·

HV floor under wire (rear traction motor cable)

·

Hybrid vehicle transaxle assembly

·

Rear traction motor with transaxle assembly

·

PCU fuse

·

Inverter with converter assembly

·

Hybrid vehicle control ECU assembly


Comes on Master Warning:
Comes on
P0D3319 DC/DC Converter Circuit Current Above Threshold Boost converter fail signal detected:
A malfunction is detected in any of the boost converter components (inverter, hybrid vehicle transaxle, motor generator control ECU, etc.).
(1 trip detection logic)
·

Inverter cooling system

·

Cooling fan system

·

Grille shutter system*

·

Wire harness or connector

·

Motor cable

·

HV floor under wire (rear traction motor cable)

·

Hybrid vehicle transaxle assembly

·

Rear traction motor with transaxle assembly

·

PCU fuse

·

Inverter with converter assembly

·

Hybrid vehicle control ECU assembly


Comes on Master Warning:
Comes on

*: w/ Grille Shutter

Related Data List
DTC No. Data List
P0A949E
P0D3319
Emergency Inverter Shut Down

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds or more.

7.

Turn the power switch on (READY) and wait for 5 seconds or more.

8.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

NOTICE:

As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.


HINT:

Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).


9.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

10.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

Refer to the wiring diagram for the Generator Resolver Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Generator Resolver Circuit

Refer to the wiring diagram for the Motor Resolver Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Motor Resolver Circuit

Refer to the wiring diagram for the Rear Motor Resolver Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Rear Motor Resolver Circuit

Refer to the wiring diagram for the Generator High-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Generator High-voltage Circuit

Refer to the wiring diagram for the Motor High-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Motor High-voltage Circuit

Refer to the wiring diagram for the Rear Motor High-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Rear Motor High-voltage Circuit

Refer to the wiring diagram for the Inverter Low-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Inverter Low-voltage Circuit

Refer to the wiring diagram for the Cooling System.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Cooling System

CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:
·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly. (The inverter with converter assembly may have been broken or damaged due to overheating.)



PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control, Motor Generator and Rear Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
P0A949E or P0D3319 only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C
DTCs of rear motor generator control system in the tables below are output. D


Table 1
Malfunction Content System Relevant DTC
Insulation Malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1C8049 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure
System Main Relay or High Voltage Circuit Malfunction Hybrid control system P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open
P1C8449 High Voltage Power Resource Circuit Short during Ready ON
HV Battery Malfunction Hybrid control system P0AFC16 Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold
P0AFC96 Hybrid/EV Battery Sensor Module Component Internal Failure
P1CBE1E Hybrid/EV Battery Block 1 Voltage Difference Out of Range
P1CBF1E Hybrid/EV Battery Block 2 Voltage Difference Out of Range
P1CC01E Hybrid/EV Battery Block 3 Voltage Difference Out of Range
P1CC11E Hybrid/EV Battery Block 4 Voltage Difference Out of Range
P1CC21E Hybrid/EV Battery Block 5 Voltage Difference Out of Range
P1CC31E Hybrid/EV Battery Block 6 Voltage Difference Out of Range
P1CC41E Hybrid/EV Battery Block 7 Voltage Difference Out of Range
P1CC51E Hybrid/EV Battery Block 8 Voltage Difference Out of Range
P1CC61E Hybrid/EV Battery Block 9 Voltage Difference Out of Range
P1CC71E Hybrid/EV Battery Block 10 Voltage Difference Out of Range
P1CFD1E Hybrid/EV Battery Block 11 Voltage Difference Out of Range
P301100 Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme)
P301200 Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme)
P301300 Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme)
P301400 Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme)
P301500 Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme)
P301600 Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme)
P301700 Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme)
P301800 Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme)
P301900 Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme)
P302000 Hybrid/EV Battery Block 10 Circuit Resistance Out of Range (Extreme)
P302100 Hybrid/EV Battery Block 11 Circuit Resistance Out of Range (Extreme)
U029A87 Lost Communication with Hybrid/EV Battery Sensor Module Missing Message

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module Watchdog / Safety MC Failure
P0A1A49 Generator Control Module Internal Electronic Failure
P0A1B1F Generator Control Module Circuit Intermittent
P0A1C47 Drive Motor "B" Control Module Watchdog / Safety MCU Failure
P0A1C49 Drive Motor "B" Control Module Internal Electronic Failure
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P1C2C1C Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
P1C2C49 Drive Motor "B" Control Module AD Converter Internal Electronic Failure
P310A83 Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P310A86 Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P310A87 Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message
P310B83 Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect
P310B86 Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P310B87 Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message
P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid
P313387 Communication Error from Generator to Drive Motor "A" Missing Message
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid
P313487 Communication Error from Drive Motor "A" to Generator Missing Message
P32BF83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect
P32BF86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P32BF87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message
P32CF83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect
P32CF86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P32CF87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message
Hybrid control system P0A1B49 Drive Motor "A" Control Module Internal Electronic Failure
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
P262C1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range
Communication malfunction Motor generator control system P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message
Hybrid control system P312387 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message
Sensor and actuator circuit malfunction Motor generator control system P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum
P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum
P0A4516 Drive Motor "B" Position Sensor Circuit Voltage Below Threshold
P0A4521 Drive Motor "B" Position Sensor Signal Amplitude < Minimum
P0A4522 Drive Motor "B" Position Sensor Signal Amplitude > Maximum
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B22 Generator Position Sensor Signal Amplitude > Maximum
P0A6012 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery
P0A6014 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open
P0A601C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range
P0A6312 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery
P0A6314 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open
P0A631C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range
P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery
P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open
P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery
P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open
P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery
P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open
P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF112 Drive Motor "B" Phase U Current Sensor Circuit Short to Battery
P0BF114 Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open
P0BF128 Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF512 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery
P0BF514 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open
P0BF528 Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF912 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery
P0BF914 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open
P0BF928 Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BFD62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure
P0BFE62 Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure
P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5513 Drive Motor "B" Position Sensor Circuit "A" Circuit Open
P0C5516 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5517 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C5F13 Drive Motor "B" Position Sensor Circuit "B" Circuit Open
P0C5F16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5F17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C6413 Generator Position Sensor Circuit "A" Circuit Open
P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C6913 Generator Position Sensor Circuit "B" Circuit Open
P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0D2D16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open
P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open
P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open
P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E3116 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold
P0E3117 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E5128 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E512A DC/DC Converter Current Sensor Signal Stuck In Range
P1CAC49 Generator Position Sensor Internal Electronic Failure
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CAE49 Drive Motor "B" Position Sensor Internal Electronic Failure
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
P1CB138 Drive Motor "B" Position Sensor REF Signal Frequency Incorrect
P1CFF62 Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure
Rear motor generator control system P0A6912 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery
P0A6914 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open
P0A691C Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range
P0A6C12 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery
P0A6C14 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open
P0A6C1C Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range
Hybrid control system P0C7600 Hybrid/EV Battery System Discharge Time Too Long
P0D2D1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
P0E311C Boosting Converter Voltage Sensor "A" Voltage Out of Range
System malfunction Motor generator control system P0A9000 Drive Motor "A" Performance
P0A9100 Drive Motor "B" Performance
P0A9200 Hybrid Generator Performance
P0BFF1D Drive Motor "A" Circuit Current Out of Range
P0C021D Drive Motor "B" System Circuit Current Out of Range
P0C1900 Drive Motor "A" Execution Torque Performance
P0C1A00 Drive Motor "B" Execution Torque Performance
P0CA300 DC/DC Converter Step Up Voltage Performance
P0E7100 Generator Execution Torque Performance
P1CA51D Hybrid Generator Circuit Current Out of Range
P314F1F DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent
P31531D DC/DC Converter Current Sensor Circuit Current Out of Range
Hybrid control system P0A9300 Inverter "A" Cooling System Performance
P0AA649 Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure
P0C7396 Motor Electronics Coolant Pump "A" Component Internal Failure
P314A31 Motor Electronics Coolant Pump "A" No Signal

Table 3
System Relevant DTC
Motor generator control system P0A3F1F Drive Motor "A" Position Sensor Circuit Intermittent
P0A4B1F Generator Position Sensor Circuit Intermittent
P0A601F Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent
P0A631F Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent
P0BE51F Drive Motor "A" Phase U Current Sensor Circuit Intermittent
P0BE91F Drive Motor "A" Phase V Current Sensor Circuit Intermittent
P0BED1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent
P0C501F Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent
P0C5A1F Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent
P0C641F Generator Position Sensor Circuit "A" Circuit Intermittent
P0C691F Generator Position Sensor Circuit "B" Circuit Intermittent
P0D2D1F Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent
P0E001F Generator Phase U Current Sensor Circuit Intermittent
P0E041F Generator Phase V Current Sensor Circuit Intermittent
P0E081F Generator Phase W Current Sensor Circuit Intermittent
P0E311F DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent
P0E511F DC/DC Converter Current Sensor Circuit Intermittent
P1C601F Generator Control Module Position Sensor REF Power Source Circuit Intermittent
P1C621F Generator Control Module Offset Power Circuit Intermittent
P1C641F Generator Control Module Circuit Intermittent
P1C651F Generator Control Module Circuit Intermittent
P1C671F Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent
P1C691F Generator Phase U-V-W Current Sensor Circuit Intermittent
P31241F Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent
Rear motor generator control system P0A451F Drive Motor "B" Position Sensor Circuit Intermittent
P0A691F Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent
P0A6C1F Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent
P0C551F Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent
P0C5F1F Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent
P1C631F Drive Motor "B" Control Module Offset Power Circuit Intermittent
P1C661F Drive Motor "B" Control Module Circuit Intermittent
P1C681F Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent

HINT:
·

P0A949E or P0D3319 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)


·

If DTC P0A949E is output, replace the inverter with converter assembly after completing repairs.




e.

Turn the power switch off.



A

2.CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION

B

C

D

2.CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.

Powertrain > Motor Generator > Utility
Tester Display
Diagnosis Related Information
50005 395 1056

d.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

Powertrain > Motor Generator > Trouble Codes
50001 395

e.

Read the diagnosis related information and freeze frame data of DTC P0A949E or P0D3319.

Result:
Result Proceed to
DTC P312487 is listed in Diagnosis Related Information. A
DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. B
Other than above C



f.

Turn the power switch off.



A

B

C

3.CHECK FREEZE FRAME DATA
3.CHECK FREEZE FRAME DATA
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

Powertrain > Motor Generator > Trouble Codes
50001 395

d.

Read the freeze frame data of DTC P0A949E or P0D3319.

Result:
Result Proceed to
Boosting Converter Temperature (Upper) and Boosting Converter Temperature 1 (Lower) are 120°C or more A
Other than above B



e.

Turn the power switch off.



A

4.CHECK COOLING SYSTEM

B

5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
4.CHECK COOLING SYSTEM

NEXT

5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

6.CHECK GENERATOR RESOLVER CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK GENERATOR RESOLVER CIRCUIT

NEXT

7.CHECK MOTOR RESOLVER CIRCUIT
7.CHECK MOTOR RESOLVER CIRCUIT

NEXT

8.CHECK REAR MOTOR RESOLVER CIRCUIT
8.CHECK REAR MOTOR RESOLVER CIRCUIT

NEXT

9.CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
9.CHECK GENERATOR HIGH-VOLTAGE CIRCUIT

NEXT

10.CHECK MOTOR HIGH-VOLTAGE CIRCUIT
10.CHECK MOTOR HIGH-VOLTAGE CIRCUIT

NEXT

11.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT
11.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT

NEXT

12.CHECK INVERTER LOW-VOLTAGE CIRCUIT
12.CHECK INVERTER LOW-VOLTAGE CIRCUIT

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Inverter Low-voltage Circuit

HINT:

If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.


Result:
Proceed to
NEXT



NEXT