HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)  P0C1A00  Drive Motor "B" Execution Torque Performance  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC indicates that the rear motor torque execution value does not correspond to the torque command value sent from the hybrid vehicle control ECU assembly to the rear motor. The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Inside of inverter Inverter with converter assembly internal circuit malfunction
Rear traction motor with transaxle assembly
·

Rear motor (MGR) internal malfunction (entry of foreign matter, etc.)

·

Open or short circuit in the rear motor coils


Inverter low-voltage circuit The connectors are not connected properly
HV floor under wire (rear traction motor cable)
·

Open circuit or poor insulation on HV floor under wire (rear traction motor cable)

·

Defective HV floor under wire (rear traction motor cable) connection


Hybrid vehicle control ECU assembly Hybrid vehicle control ECU assembly internal circuit malfunction


DESCRIPTION

For a description of the inverter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>P0D2D16

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0C1A00 Drive Motor "B" Execution Torque Performance Rear motor torque execution monitoring malfunction:
The difference between the rear motor torque requested by the motor generator control ECU and actual rear motor torque is large.
(1 trip detection logic)
·

Inverter with converter assembly

·

Motor cable

·

HV floor under wire (rear traction motor cable)

·

Hybrid vehicle transaxle assembly

·

Rear traction motor with transaxle assembly

·

Hybrid vehicle control ECU assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on

Related Data List
DTC No. Data List
P0C1A00
·

Rear Motor Torque

·

Target Rear Motor Torque (Hybrid control system)

·

Vehicle Speed



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Turn the power switch on (READY) and wait for 5 seconds or more.

7.

Move the shift lever to D, and then accelerate until the vehicle speed is 20 km/h (12.5 mph) and the accelerator position is approximately 25%.

8.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

9.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control, Motor Generator and Rear Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
P0C1A00 only is output, or DTCs except the ones in the tables below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C
DTCs of rear motor generator control system in the tables below are output. D


Table 1
Malfunction Content System Relevant DTC
Insulation Malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
System Main Relay or High Voltage Circuit Malfunction Hybrid control system P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open
P1C8449 High Voltage Power Resource Circuit Short during Ready ON

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module Watchdog / Safety MC Failure
P0A1A49 Generator Control Module Internal Electronic Failure
P0A1B1F Generator Control Module Circuit Intermittent
P0A1C49 Drive Motor "B" Control Module Internal Electronic Failure
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P1C2C1C Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
P1C2C49 Drive Motor "B" Control Module AD Converter Internal Electronic Failure
P310A83 Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P310A86 Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P310A87 Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message
P310B83 Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect
P310B86 Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P310B87 Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message
P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid
P313387 Communication Error from Generator to Drive Motor "A" Missing Message
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid
P313487 Communication Error from Drive Motor "A" to Generator Missing Message
P32BF83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect
P32BF86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P32BF87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message
P32CF83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect
P32CF86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
P32CF87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message
Hybrid control system P0A1B49 Drive Motor "A" Control Module Internal Electronic Failure
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Sensor and actuator circuit malfunction Motor generator control system P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum
P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum
P0A4516 Drive Motor "B" Position Sensor Circuit Voltage Below Threshold
P0A4521 Drive Motor "B" Position Sensor Signal Amplitude < Minimum
P0A4522 Drive Motor "B" Position Sensor Signal Amplitude > Maximum
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B22 Generator Position Sensor Signal Amplitude > Maximum
P0A6012 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery
P0A6014 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open
P0A601C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range
P0A6312 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery
P0A6314 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open
P0A631C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range
P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery
P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open
P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery
P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open
P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery
P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open
P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF112 Drive Motor "B" Phase U Current Sensor Circuit Short to Battery
P0BF114 Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open
P0BF128 Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF512 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery
P0BF514 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open
P0BF528 Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF912 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery
P0BF914 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open
P0BF928 Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BFD62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure
P0BFE62 Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure
P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5513 Drive Motor "B" Position Sensor Circuit "A" Circuit Open
P0C5516 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5517 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C5F13 Drive Motor "B" Position Sensor Circuit "B" Circuit Open
P0C5F16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5F17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C6413 Generator Position Sensor Circuit "A" Circuit Open
P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C6913 Generator Position Sensor Circuit "B" Circuit Open
P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0D2D16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open
P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open
P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open
P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E3116 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold
P0E3117 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E512A DC/DC Converter Current Sensor Signal Stuck In Range
P1CAC49 Generator Position Sensor Internal Electronic Failure
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CAE49 Drive Motor "B" Position Sensor Internal Electronic Failure
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
P1CB138 Drive Motor "B" Position Sensor REF Signal Frequency Incorrect
Rear motor generator control system P0A6912 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery
P0A6914 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open
P0A691C Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range
P0A6C12 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery
P0A6C14 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open
P0A6C1C Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range
Hybrid control system P0C7600 Hybrid/EV Battery System Discharge Time Too Long
P0D2D1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
P0E311C Boosting Converter Voltage Sensor "A" Voltage Out of Range
P1C2D62 Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure
System malfunction Motor generator control system P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed
P0A7973 Drive Motor "B" Inverter Actuator Stuck Closed
P0A7A73 Generator Inverter Actuator Stuck Closed

HINT:
·

P0C1A00 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION

B

C

D

2.CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.

Powertrain > Motor Generator > Utility
Tester Display
Diagnosis Related Information
50005 395 1056

d.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

Powertrain > Motor Generator > Trouble Codes
50001 395

e.

Read the diagnosis related information and freeze frame data of DTC P0C1A00.

Result:
Result Proceed to
DTC P312487 is listed in Diagnosis Related Information. A
DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. B
Other than above C



f.

Turn the power switch off.



A

B

C

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

4.CHECK SHUT DOWN SIGNAL CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK SHUT DOWN SIGNAL CIRCUIT

NEXT

5.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT
5.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT

NEXT

6.CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
6.CHECK GENERATOR HIGH-VOLTAGE CIRCUIT

NEXT

7.CHECK MOTOR HIGH-VOLTAGE CIRCUIT
7.CHECK MOTOR HIGH-VOLTAGE CIRCUIT

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>Motor High-voltage Circuit

HINT:

If the "Motor High-voltage Circuit" inspection results are normal, perform the next step.


Result:
Proceed to
NEXT



NEXT