HYBRID VEHICLE CONTROL ECU ASSEMBLY
| *A | for LHD | *B | for RHD |
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Input/Output | Condition | Specified Condition |
|---|---|---|---|---|---|
| A29-2 (R) - A30-3 (E1) | LG - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in R | 0 to 1.5 V | ||||
| A29-3 (DB1) - A30-3 (E1) | W - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-4 (HMCH) - A30-3 (E1) | B - W-B | CAN Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-5 (MREL) - A30-3 (E1) | LG - W-B | Main relay | Output | Power switch on (IG) | 11 to 14 V |
| A29-6 (HSDN) - A30-3 (E1) | G - W-B | MG ECU shutdown signal | Output | Power switch on (READY) | 0 to 1.5 V |
| A29-7 (STP) - A30-3 (E1) | G - W-B | Stop light switch | Input | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | ||||
| A29-8 (LIN3) - A30-3 (E1) | L - W-B | LIN communication signal
(A/C inverter, auxiliary battery) |
Input/Output | Power switch on (READY) | Pulse generation |
| A29-11 (+B1) - A30-3 (E1) | R - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A29-14 (HMCL) - A30-3 (E1) | W - W-B | Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-15 (DB2) - A30-3 (E1) | P - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-16 (PR) - A30-3 (E1) | R - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P or R | 0 to 1.5 V | ||||
| A29-18 (PSFT) - A30-3 (E1) | L - W-B | Shift lever position sensor power source | Output | Power switch on (ACC) | 7.5 to 14 V |
| A29-20 (BL) - A30-3 (E1) | LA-BE - W-B | Back-up light relay | Output | Power switch on (IG), shift lever in R | 11 to 14 V |
| A29-24 (VCPA) - A29-37 (EPA) | R - L | Accelerator pedal sensor assembly power source (for VPA) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-26 (VCP2) - A29-25 (EPA2) | SB - P | Accelerator pedal sensor assembly power source (for VPA2) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-28 (P) - A30-3 (E1) | BR - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P | 0 to 1.5 V | ||||
| A29-29 (N) - A30-3 (E1) | G - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in N | 7.5 to 14 V |
| Power switch on (IG), shift lever not in N | 0 to 1.5 V | ||||
| A29-30 (PNB) - A30-3 (E1) | B - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or N | 7.5 to 14 V |
| A29-33 (NIWP) - A30-3 (E1) | W - W-B | Inverter water pump assembly signal | Input | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-34 (IWP) - A30-3 (E1) | L - W-B | Inverter water pump assembly signal | Output | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-36 (VPA) - A29-37 (EPA) | G - L | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 2.6 to 4.5 V | ||||
| A29-38 (VPA2) - A29-25 (EPA2) | GR - P | Accelerator pedal sensor assembly (for accelerator pedal sensor malfunction detection) | Input | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 3.4 to 5.3 V | ||||
| A29-40 (TTA) - A29-39 (ETTA) | GR - W | Transmission fluid temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-42 (RMT) - A29-43 (RMTG) | L - W | Rear motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-46 (MMT) - A29-45 (MMTG) | Y - BE | Motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-48 (GMT) - A29-47 (GMTG) | G - V | Generator temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A30-1 (+B2) - A30-3 (E1) | BE - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A30-4 (ST2) - A30-3 (E1) | L - W-B | Starter signal | Input | Power switch on (IG) | 0 to 1.5 V |
| A30-7 (INDR) - A30-3 (E1) | LG - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in R | 0 to 3.2 V |
| Power switch on (IG), shift lever not in R | 11 to 14 V | ||||
| A30-8 (INDD) - A30-3 (E1) | W - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in D | 0 to 3.2 V |
| Power switch on (IG), shift lever not in D | 11 to 14 V | ||||
| A30-11 (SFTD) - A30-3 (E1) | G - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (-) or shift paddle switch LH (-) operated | 0 to 1.5 V | ||||
| A30-19 (INDP) - A30-3 (E1) | B - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in P | 0 to 3.2 V |
| Power switch on (IG), shift lever not in P | 11 to 14 V | ||||
| A30-20 (INDM) - A30-3 (E1) | LA-Y - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in S | 0 to 3.2 V |
| Power switch on (IG), shift lever not in S | 11 to 14 V | ||||
| A30-21 (INDN) - A30-3 (E1) | R - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in N | 0 to 3.2 V |
| Power switch on (IG), shift lever not in N | 11 to 14 V | ||||
| A30-24 (SFTU) - A30-3 (E1) | Y - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (+) or shift paddle switch RH (+) operated | 0 to 1.5 V | ||||
| A30-25 (M) - A30-3 (E1) | LA-B - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever not in S | 0 to 1.5 V | ||||
| A30-27 (BATT) - A30-3 (E1) | B - W-B | Constant power source | Input | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | ||||
| A30-33 (EVSW) - A30-3 (E1) | G - W-B | EV mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), EV mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| A30-36 (ALSD) - A30-3 (E1) | B - W-B | TRAIL mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), TRAIL mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), TRAIL mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| A30-37 (SPRT) - A30-3 (E1) | R - W-B | SPORT mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), SPORT mode switch (integration control and panel assembly) not turned | 11 to 14 V |
| Power switch on (IG), SPORT mode switch (integration control and panel assembly) being turned and held | 0 to 1.5 V | ||||
| A30-38 (NORM) - A30-3 (E1) | SB - W-B | NORMAL mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), NORMAL mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), NORMAL mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| A30-44 (IGB) - A30-3 (E1) | GR - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A31-5 (ILK) - A30-3 (E1) | V - W-B | Interlock switch | Input | Power switch on (IG), service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), service plug grip not installed | 11 to 14 V | ||||
| A31-7 (CA3P) - A30-3 (E1) | G - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 5) |
| A31-8 (CA1L) - A30-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 4) |
| A31-9 (CA4H) - A30-3 (E1) | R - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| A31-13 (SMRG) - A31-12 (E01) | G - W-B | System main relay operation signal | Output | Power switch on (IG)→ Power switch on (READY) | Pulse generation
(Waveform 3) |
| A31-15 (SMRP) - A31-12 (E01) | W - W-B | System main relay operation signal | Output | Power switch on (IG)→ Power switch on (READY) | Pulse generation
(Waveform 3) |
| A31-16 (SMRB) - A31-12 (E01) | GR - W-B | System main relay operation signal | Output | Power switch on (IG)→ Power switch on (READY) | Pulse generation
(Waveform 3) |
| A31-20 (CA3N) - A30-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 5) |
| A31-21 (CA1H) - A30-3 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 4) |
| A31-22 (CA4L) - A30-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| A31-25 (PLKC) - A30-3 (E1) | BE - W-B | Shift lock release request signal | Output | Power switch on (READY), brake pedal depressed | 11 to 14 V |
| Power switch on (READY), brake pedal released | 0 to 1.5 V | ||||
| A31-28 (ST1-) - A30-3 (E1) | LA-G - W-B | Stop light switch signal | Input | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | ||||
| A31-29 (ACCI) - A30-3 (E1) | P - W-B | ACC relay | Input | Power switch on (ACC) | 11 to 14 V |
| A31-35 (IG2) - A30-3 (E1) | B - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Input/Output | Condition | Specified Condition |
|---|---|---|---|---|---|
| A29-2 (R) - G63-3 (E1) | LG - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in R | 0 to 1.5 V | ||||
| A29-3 (DB1) - G63-3 (E1) | W - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-4 (HMCH) - G63-3 (E1) | B - W-B | CAN Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-5 (MREL) - G63-3 (E1) | W - W-B | Main relay | Output | Power switch on (IG) | 11 to 14 V |
| A29-6 (HSDN) - G63-3 (E1) | G - W-B | MG ECU shutdown signal | Output | Power switch on (READY) | 0 to 1.5 V |
| A29-7 (STP) - G63-3 (E1) | G - W-B | Stop light switch | Input | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | ||||
| A29-8 (LIN3) - G63-3 (E1) | L - W-B | LIN communication signal
(A/C inverter, auxiliary battery) |
Input/Output | Power switch on (READY) | Pulse generation |
| A29-11 (+B1) - G63-3 (E1) | R - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A29-14 (HMCL) - G63-3 (E1) | W - W-B | Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-15 (DB2) - G63-3 (E1) | P - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-16 (PR) - G63-3 (E1) | R - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P or R | 0 to 1.5 V | ||||
| A29-18 (PSFT) - G63-3 (E1) | L - W-B | Shift lever position sensor power source | Output | Power switch on (ACC) | 7.5 to 14 V |
| A29-20 (BL) - G63-3 (E1) | LA-BE - W-B | Back-up light relay | Output | Power switch on (IG), shift lever in R | 11 to 14 V |
| A29-24 (VCPA) - A29-37 (EPA) | R - L | Accelerator pedal sensor assembly power source (for VPA) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-26 (VCP2) - A29-25 (EPA2) | SB - P | Accelerator pedal sensor assembly power source (for VPA2) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-28 (P) - G63-3 (E1) | BR - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P | 0 to 1.5 V | ||||
| A29-29 (N) - G63-3 (E1) | G - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in N | 7.5 to 14 V |
| Power switch on (IG), shift lever not in N | 0 to 1.5 V | ||||
| A29-30 (PNB) - G63-3 (E1) | B - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or N | 7.5 to 14 V |
| A29-33 (NIWP) - G63-3 (E1) | W - W-B | Inverter water pump assembly signal | Input | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-34 (IWP) - G63-3 (E1) | L - W-B | Inverter water pump assembly signal | Output | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-36 (VPA) - A29-37 (EPA) | G - L | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 2.6 to 4.5 V | ||||
| A29-38 (VPA2) - A29-25 (EPA2) | GR - P | Accelerator pedal sensor assembly (for accelerator pedal sensor malfunction detection) | Input | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 3.4 to 5.3 V | ||||
| A29-40 (TTA) - A29-39 (ETTA) | GR - W | Transmission fluid temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-42 (RMT) - A29-43 (RMTG) | L - W | Rear motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-46 (MMT) - A29-45 (MMTG) | Y - BE | Motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-48 (GMT) - A29-47 (GMTG) | G - V | Generator temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| G63-1 (+B2) - G63-3 (E1) | BE - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| G63-4 (ST2) - G63-3 (E1) | L - W-B | Starter signal | Input | Power switch on (IG) | 0 to 1.5 V |
| G63-7 (INDR) - G63-3 (E1) | LG - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in R | 0 to 3.2 V |
| Power switch on (IG), shift lever not in R | 11 to 14 V | ||||
| G63-8 (INDD) - G63-3 (E1) | W - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in D | 0 to 3.2 V |
| Power switch on (IG), shift lever not in D | 11 to 14 V | ||||
| G63-11 (SFTD) - G63-3 (E1) | W - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (-) or shift paddle switch LH (-) operated | 0 to 1.5 V | ||||
| G63-19 (INDP) - G63-3 (E1) | B - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in P | 0 to 3.2 V |
| Power switch on (IG), shift lever not in P | 11 to 14 V | ||||
| G63-20 (INDM) - G63-3 (E1) | LA-Y - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in S | 0 to 3.2 V |
| Power switch on (IG), shift lever not in S | 11 to 14 V | ||||
| G63-21 (INDN) - G63-3 (E1) | R - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in N | 0 to 3.2 V |
| Power switch on (IG), shift lever not in N | 11 to 14 V | ||||
| G63-24 (SFTU) - G63-3 (E1) | Y - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (+) or shift paddle switch RH (+) operated | 0 to 1.5 V | ||||
| G63-25 (M) - G63-3 (E1) | LA-B - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever not in S | 0 to 1.5 V | ||||
| G63-27 (BATT) - G63-3 (E1) | B - W-B | Constant power source | Input | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | ||||
| G63-33 (EVSW) - G63-3 (E1) | G - W-B | EV mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), EV mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| G63-36 (ALSD) - G63-3 (E1) | B - W-B | TRAIL mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), TRAIL mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), TRAIL mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| G63-37 (SPRT) - G63-3 (E1) | R - W-B | SPORT mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), SPORT mode switch (integration control and panel assembly) not turned | 11 to 14 V |
| Power switch on (IG), SPORT mode switch (integration control and panel assembly) being turned and held | 0 to 1.5 V | ||||
| G63-38 (NORM) - G63-3 (E1) | SB - W-B | NORMAL mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), NORMAL mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), NORMAL mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| G63-44 (IGB) - G63-3 (E1) | GR - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| G64-5 (ILK) - G63-3 (E1) | V - W-B | Interlock switch | Input | Power switch on (IG), service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), service plug grip not installed | 11 to 14 V | ||||
| G64-7 (CA3P) - G63-3 (E1) | G - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 5) |
| G64-8 (CA1L) - G63-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 4) |
| G64-9 (CA4H) - G63-3 (E1) | R - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| G64-13 (SMRG) - G64-12 (E01) | G - W-B | System main relay operation signal | Output | Power switch on (IG)→ Power switch on (READY) | Pulse generation
(Waveform 3) |
| G64-15 (SMRP) - G64-12 (E01) | W - W-B | System main relay operation signal | Output | Power switch on (IG)→ Power switch on (READY) | Pulse generation
(Waveform 3) |
| G64-16 (SMRB) - G64-12 (E01) | GR - W-B | System main relay operation signal | Output | Power switch on (IG)→ Power switch on (READY) | Pulse generation
(Waveform 3) |
| G64-20 (CA3N) - G63-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 5) |
| G64-21 (CA1H) - G63-3 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 4) |
| G64-22 (CA4L) - G63-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| G64-25 (PLKC) - G63-3 (E1) | BE - W-B | Shift lock release request signal | Output | Power switch on (READY), brake pedal depressed | 11 to 14 V |
| Power switch on (READY), brake pedal released | 0 to 1.5 V | ||||
| G64-28 (ST1-) - G63-3 (E1) | LA-G - W-B | Stop light switch signal | Input | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | ||||
| G64-29 (ACCI) - G63-3 (E1) | P - W-B | ACC relay | Input | Power switch on (ACC) | 11 to 14 V |
| G64-35 (IG2) - G63-3 (E1) | B - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (Inverter water pump assembly signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A29-34 (IWP) - A30-3 (E1) CH2: A29-33 (NIWP) - A30-3 (E1) for RHD:
CH1: A29-34 (IWP) - G63-3 (E1) CH2: A29-33 (NIWP) - G63-3 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY) |
The duty of the IWP signal and the frequency of the NIWP signal change according to the coolant (for inverter) temperature.
Waveform 2 (MG ECU communication request signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A29-4 (HMCH) - A30-3 (E1) CH2: A29-14 (HMCL) - A30-3 (E1) for RHD:
CH1: A29-4 (HMCH) - G63-3 (E1) CH2: A29-14 (HMCL) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3 (System main relay operation signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-15 (SMRP) - A31-12 (E01) CH2: A31-16 (SMRB) - A31-12 (E01) CH3: A31-13 (SMRG) - A31-12 (E01) for RHD:
CH1: G64-15 (SMRP) - G64-12 (E01) CH2: G64-16 (SMRB) - G64-12 (E01) CH3: G64-13 (SMRG) - G64-12 (E01) |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG)→ Power switch on (READY) |
Waveform 4 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-21 (CA1H) - A30-3 (E1) CH2: A31-8 (CA1L) - A30-3 (E1) for RHD:
CH1: G64-21 (CA1H) - G63-3 (E1) CH2: G64-8 (CA1L) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 5 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-7 (CA3P) - A30-3 (E1) CH2: A31-20 (CA3N) - A30-3 (E1) for RHD:
CH1: G64-7 (CA3P) - G63-3 (E1) CH2: G64-20 (CA3N) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 6 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-9 (CA4H) - A30-3 (E1) CH2: A31-22 (CA4L) - A30-3 (E1) for RHD:
CH1: G64-9 (CA4H) - G63-3 (E1) CH2: G64-22 (CA4L) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).