DATA LIST
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model, operating under identical conditions in order to reach an overall judgment by comparing all of the items in the Data List.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Rear Motor Generator / Data List.
Check the results by referring to the following table.
When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
Using a custom list makes it possible to easily select smaller groups of related Data List items.
The following custom lists are available:
All Data
Inverter
Resolver
DC/DC Converter
Resolver Learning
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Engine Speed | Engine speed | Min.: 0 rpm, Max.: 16383 rpm | Engine stopped:
0 rpm While engine running at a constant speed: No significant fluctuation |
- |
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | Vehicle stopped:
0 km/h (0 mph) While driving at a constant speed: No significant fluctuation |
- |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec | - | Elapsed time from initial engine start until the power switch is turned off. |
| Warmup Cycle Cleared DTC | Warmup cycles after DTCs cleared | Min.: 0, Max.: 255 | - | - |
| Distance from DTC Cleared | Distance driven after DTCs cleared | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Battery Voltage | Auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V | 11 to 15 V: Power switch on (IG) | When power switch on (READY): approx. 12.5 to 15.0 V. When power switch on (IG): same as auxiliary battery voltage (approx. 12 V).
If the voltage becomes 11 V or less when the power switch is on (READY), the hybrid vehicle control ECU assembly stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY). |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Power switch on (IG):
Same as ambient air temperature |
- |
| Time after DTC Cleared | Time after DTCs cleared | Min.: 0 min, Max.: 65535 min | - | - |
| Hybrid/EV Battery System Voltage | HV battery voltage | Min.: 0 V, Max.: 510 V | Power switch on (READY):
150 to 300 V |
- |
| Hybrid/EV Battery System Current | HV battery current | Min.: -3276.8 A, Max.: 3276.7 A | Power switch on (IG):
-4 to 4 A |
- |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -20000 rpm, Max.: 20000 rpm | While driving:
Varies depending on vehicle speed |
Motor (MG2) speed changes in proportion to vehicle speed.
Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed. |
| Motor Torque | Motor (MG2) torque value | Min.: -500 Nm, Max.: 500 Nm | While driving:
Varies depending on vehicle operating conditions |
- |
| Motor Control Mode | Motor control mode | Min.: 0, Max.: 65535 | - | - |
| Generator Revolution | Generator (MG1) speed (detected by resolver sensor) | Min.: -20000 rpm, Max.: 20000 rpm | During charge or discharge:
Varies depending on vehicle operating conditions |
Generator (MG1) speed is set to obtain requested target engine speed |
| Generator Torque | Generator (MG1) torque value | Min.: -500 Nm, Max.: 500 Nm | During charge or discharge:
Varies depending on vehicle operating conditions |
- |
| Generator Control Mode | Generator control mode | Min.: 0, Max.: 65535 | - | - |
| VL Voltage | High voltage before it is boosted | Min.: 0.0 V, Max.: 500.0 V | Power switch on (READY):
Practically the same as the HV battery voltage |
- |
| VH Voltage | High voltage after it is boosted | Min.: 0.0 V, Max.: 1000.0 V | Engine revving up with shift lever in P:
After boosted voltage to below 650 V |
- |
| Boosting Converter PWM Duty | Boost converter PWM duty | Min.: 0 %, Max.: 100 % | - | - |
| Boosting Converter Control Mode | Boost converter control mode | Min.: 0, Max.: 255 | - | - |
| Short Wave Highest Value | Waveform voltage in abnormal insulation detection circuit in battery voltage sensor | Min.: 0.00 V, Max.: 4.98 V | - | - |
| Fail Safe Mode | Fail safe mode | Min.: -128, Max.: 127 | - | - |
| Accelerator Position | Accelerator position | Min.: 0.0 %, Max.: 100.0 % | Accelerator pedal depressed:
Changes with accelerator pedal pressure |
- |
| WIN Control Limit Power | Power flowing to HV battery (Charging)
(detected at battery voltage sensor) |
Min.: -327.68 kW, Max.: 327.67 kW | -38.76 kW or more | - |
| WOUT Control Limit Power | Power flowing from HV battery (Discharging)
(detected at battery voltage sensor) |
Min.: -327.68 kW, Max.: 327.67 kW | 25.50 kW or less | - |
| Rear Motor Resolver After Offset | Rear motor resolver after offset | Min.: 0.000 deg, Max.: 358.593 deg | - | - |
| Rear Motor Revolution | Rear motor (MGR) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | While driving:
Varies depending on vehicle operating conditions |
- |
| Rear Motor Torque | Rear motor (MGR) torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm | While driving:
Varies depending on vehicle operating conditions |
- |
| Rear Motor Control Mode | Rear motor control mode | Min.: 0, Max.: 65535 | - | - |
| Rear Motor Carrier Frequency | Rear motor carrier frequency | Min.: 0, Max.: 255 | - | - |
| Rear Motor Inverter Shut Down Signal | Rear motor inverter shutdown signal | Min.: 0, Max.: 255 | - | - |
| Rear Motor Inverter Temperature | Rear motor inverter temperature | Min.: 0°C (32°F), Max.: 150°C (302°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F) While driving with an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
- |
| Rear Motor Temperature | Rear motor (MGR) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F) Changes according to vehicle condition and ambient temperature |
- |
| Rear Motor Inverter Temperature Duty | Rear motor inverter temperature duty (CPU input data) | Min.: 0.0 %, Max.: 6553.5 % | - | - |
| Emergency Shutdown Signal | Inverter emergency shutdown | ON or OFF | Inverter emergency shutdown:
ON Normal: OFF |
- |
| Ready ON Status | State of system (READY) | ON or OFF | Power switch on (READY):
ON |
- |
| SMR Status | System main relay status | ON or OFF | Power switch on (READY):
ON |
- |
| Generator Inverter High Current(GFINV) | Generator (MG1) inverter high current | ON or OFF | Normal:
OFF |
- |
| Generator Inverter Shut Down Status | Generator (MG1) inverter shutdown status | ON or OFF | Generator inverter shutdown:
ON Normal: OFF |
- |
| Motor Inverter High Current(MFINV) | Motor inverter high current | ON or OFF | Normal:
OFF |
- |
| Motor Inverter Shut Down Status | Motor inverter shutdown status | ON or OFF | Motor inverter shutdown:
ON Normal: OFF |
- |
| Boosting Converter Input High Voltage | Boost converter input high voltage | ON or OFF | Normal:
OFF |
- |
| Boosting Converter Input High Current(CFINV) | Boost converter input high current | ON or OFF | Normal:
OFF |
- |
| Boosting Converter Shut Down Status | Boost converter shutdown status | ON or OFF | Boost converter shutdown:
ON Normal: OFF |
- |
| Rear Inverter Input High Current (RFINV) | Rear inverter input high current | ON or OFF | Normal:
OFF |
- |
| Rear Inverter Shut Down Status | Rear inverter shutdown status | ON or OFF | Rear motor inverter shutdown:
ON Normal: OFF |
- |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - | - |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile | - | - |
| Rear Motor Resolver Offset Value | Rear motor resolver offset value | Min.: -250.000 deg, Max.: 249.992 deg | - | - |
| Rear Motor Resolver Offset Complete Status | Rear motor resolver learning complete status | ON or OFF | Rear motor resolver learning has been completed:
ON |
- |
| Rear Motor U Current (Lower Resolution) | Rear motor U phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Rear Motor V Current (Lower Resolution) | Rear motor V phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Rear Motor W Current (Lower Resolution) | Rear motor W phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A | - | - |