Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2020.05
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0425054 REAR MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY) C

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY)  P0BF112  Drive Motor "B" Phase U Current Sensor Circuit Short to Battery  P0BF114  Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open  P0BF11F  Drive Motor "B" Phase U Current Sensor Circuit Intermittent  P0BF512  Drive Motor "B" Phase V Current Sensor Circuit Short to Battery  P0BF514  Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open  P0BF51F  Drive Motor "B" Phase V Current Sensor Circuit Intermittent  P0BF912  Drive Motor "B" Phase W Current Sensor Circuit Short to Battery  P0BF914  Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open  P0BF91F  Drive Motor "B" Phase W Current Sensor Circuit Intermittent  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:


Inverter internal malfunction

Inverter with converter assembly internal circuit malfunction


Inverter low-voltage circuit malfunction

The connectors are not connected properly


DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the rear motor inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0BF112 Drive Motor "B" Phase U Current Sensor Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase U main sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning:
Comes on
P0BF114 Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase U main sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning:
Comes on
P0BF11F Drive Motor "B" Phase U Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase U main sensor) when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning:
Does not come on
P0BF512 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase V main sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning:
Comes on
P0BF514 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase V main sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning:
Comes on
P0BF51F Drive Motor "B" Phase V Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase V main sensor) when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning:
Does not come on
P0BF912 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase W main sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning:
Comes on
P0BF914 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase W main sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Comes on Master Warning:
Comes on
P0BF91F Drive Motor "B" Phase W Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase W main sensor) when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Does not come on Master Warning:
Does not come on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds or more.

7.

Turn the power switch on (READY) and wait for 5 seconds or more.

8.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

9.

Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.

10.

Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.

11.

Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.

12.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.GO TO MOTOR GENERATOR CONTROL SYSTEM
a.

Go to Motor Generator Control System.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with LITHIUM-ION BATTERY)>P0BF112

HINT:

For the P0BF112, P0BF114, P0BF11F, P0BF512, P0BF514, P0BF51F, P0BF912, P0BF914 and P0BF91F inspection procedures, refer to the Motor Generator Control System section.



Result:
Result
NEXT



NEXT

END