Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM (for 2WD with LITHIUM-ION BATTERY) › from 2020.05
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0427173 MOTOR GENERATOR CONTROL SYSTEM(for 2WD with LITHIUM-ION BATTERY) S

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for 2WD with LITHIUM-ION BATTERY)  DIAGNOSTIC TROUBLE CODE CHART  


Motor Generator Control System
DTC No. Detection Item MIL Warning Indicate Link
P033500 Crankshaft Position Sensor "A" Does not come on Master Warning Light:
Comes on
Click here
P033531 Crankshaft Position Sensor "A" No Signal Does not come on Master Warning Light:
Comes on
Click here
P034000 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Does not come on Master Warning Light:
Comes on
Click here
P034031 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal Does not come on Master Warning Light:
Comes on
Click here
P062F44 Internal Control Module EEPROM Data Memory Failure Comes on Master Warning Light:
Does not come on
Click here
P062F46 Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure Comes on Master Warning Light:
Comes on
Click here
P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P0A0011 Motor Electronics Coolant Temperature Sensor Circuit Short to Ground Comes on Master Warning Light:
Comes on
Click here
P0A0015 Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Click here
P0A001C Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P0A0812 DC/DC Converter Status Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Click here
P0A0814 DC/DC Converter Status Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Click here
P0A1112 DC/DC Converter Enable Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Click here
P0A1114 DC/DC Converter Enable Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Click here
P0A1A47 Generator Control Module Watchdog / Safety μC Failure Comes on Master Warning Light:
Comes on
Click here
P0A1A49 Generator Control Module Internal Electronic Failure Comes on Master Warning Light:
Comes on
Click here
P0A1B1F Generator Control Module Circuit Intermittent Comes on Master Warning Light:
Comes on
Click here
P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0A3F1F Drive Motor "A" Position Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum Comes on Master Warning Light:
Comes on
Click here
P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum Comes on Master Warning Light:
Comes on
Click here
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0A4B1F Generator Position Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0A4B21 Generator Position Sensor Signal Amplitude < Minimum Comes on Master Warning Light:
Comes on
Click here
P0A4B22 Generator Position Sensor Signal Amplitude > Maximum Comes on Master Warning Light: Click here
P0A6012 Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Click here
P0A6014 Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Click here
P0A601C Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range Does not come on Master Warning Light:
Comes on
Click here
P0A601F Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0A6312 Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Click here
P0A6314 Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Click here
P0A631C Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range Does not come on Master Warning Light:
Comes on
Click here
P0A631F Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0A7872 Drive Motor "A" Inverter Actuator Stuck Open Comes on Master Warning Light:
Comes on
Click here
P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed Comes on Master Warning Light:
Comes on
Click here
P0A789E Drive Motor "A" Inverter Stuck On Comes on Master Warning Light:
Comes on
Click here
P0A7A72 Generator Inverter Actuator Stuck Open Comes on Master Warning Light:
Comes on
Click here
P0A7A73 Generator Inverter Actuator Stuck Closed Comes on Master Warning Light:
Comes on
Click here
P0A7A9E Generator Inverter Stuck On Comes on Master Warning Light:
Comes on
Click here
P0A9000 Drive Motor "A" Performance Comes on Master Warning Light:
Comes on
Click here
P0A9200 Hybrid Generator Performance Comes on Master Warning Light:
Comes on
Click here
P0A949E DC/DC Converter Stuck On Comes on Master Warning Light:
Comes on
Click here
P0AED11 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground Comes on Master Warning Light:
Comes on
Click here
P0AED15 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Click here
P0AED1C Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Click here
P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Click here
P0BE51F Drive Motor "A" Phase U Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Click here
P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Click here
P0BE91F Drive Motor "A" Phase V Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Click here
P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Click here
P0BED1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0BFD62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure Comes on Master Warning Light:
Comes on
Click here
P0BFF1D Drive Motor "A" Circuit Current Out of Range Comes on Master Warning Light:
Comes on
Click here
P0C1900 Drive Motor "A" Execution Torque Performance Comes on Master Warning Light:
Comes on
Click here
P0C3811 DC/DC Converter Temperature Sensor "A" Circuit Short to Ground Comes on Master Warning Light:
Comes on
Click here
P0C3815 DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Click here
P0C381C DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P0C3D11 DC/DC Converter Temperature Sensor "B" Circuit Short to Ground Comes on Master Warning Light:
Comes on
Click here
P0C3D15 DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Click here
P0C3D1C DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open Comes on Master Warning Light:
Comes on
Click here
P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0C501F Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open Comes on Master Warning Light:
Comes on
Click here
P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0C5A1F Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0C6413 Generator Position Sensor Circuit "A" Circuit Open Comes on Master Warning Light:
Comes on
Click here
P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0C641F Generator Position Sensor Circuit "A" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0C6913 Generator Position Sensor Circuit "B" Circuit Open Comes on Master Warning Light:
Comes on
Click here
P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0C691F Generator Position Sensor Circuit "B" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0C7917 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0CA300 DC/DC Converter Step Up Voltage Performance Comes on Master Warning Light:
Comes on
Click here
P0D2D16 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0D2D17 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0D2D1F Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0D3319 DC/DC Converter Circuit Current Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure Comes on Master Warning Light:
Comes on
Click here
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Click here
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Click here
P0E001F Generator Phase U Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Click here
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Click here
P0E041F Generator Phase V Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Click here
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Click here
P0E081F Generator Phase W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0E3116 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Click here
P0E3117 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0E311F DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground Comes on Master Warning Light:
Comes on
Click here
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Click here
P0E511F DC/DC Converter Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P0E5128 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Click here
P0E512A DC/DC Converter Current Sensor Signal Stuck In Range Comes on Master Warning Light:
Comes on
Click here
P0E5717 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Click here
P0E5811 DC/DC Converter Temperature Sensor 2 Circuit Short to Ground Comes on Master Warning Light:
Comes on
Click here
P0E5815 DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Click here
P0E581C DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P0E7100 Generator Execution Torque Performance Comes on Master Warning Light:
Comes on
Click here
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure Comes on Master Warning Light:
Comes on
Click here
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Click here
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure Comes on Master Warning Light:
Comes on
Click here
P1C2E46 Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure Does not come on Master Warning Light:
Comes on
Click here
P1C5D19 Drive Motor "A" Inverter Circuit Current Above Threshold Comes on Master Warning Light:
Comes on
Click here
P1C5F19 Generator Inverter Circuit Current Above Threshold Comes on Master Warning Light:
Comes on
Click here
P1C601F Generator Control Module Position Sensor REF Power Source Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P1C621F Generator Control Module Offset Power Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P1C641F Generator Control Module Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P1C651F Generator Control Module Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P1C671F Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P1C691F Generator Phase U-V-W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P1CA51D Hybrid Generator Circuit Current Out of Range Comes on Master Warning Light:
Comes on
Click here
P1CAC49 Generator Position Sensor Internal Electronic Failure Comes on Master Warning Light:
Comes on
Click here
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure Comes on Master Warning Light:
Comes on
Click here
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect Comes on Master Warning Light:
Comes on
Click here
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect Comes on Master Warning Light:
Comes on
Click here
P1CB59E DC/DC Converter Voltage Sensor "A"(VL) Stuck On Comes on Master Warning Light:
Comes on
Click here
P1CB69E Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On Comes on Master Warning Light:
Comes on
Click here
P1CCC96 DC/DC Converter Enable Component Internal Failure Does not come on Master Warning Light:
Comes on
Click here
P1CFF62 Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure Comes on Master Warning Light:
Comes on
Click here
P31241F Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Click here
P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message Comes on Master Warning Light:
Comes on
Click here
P313383 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect Comes on Master Warning Light:
Comes on
Click here
P313386 Communication Error from Generator to Drive Motor "A" Signal Invalid Comes on Master Warning Light:
Comes on
Click here
P313387 Communication Error from Generator to Drive Motor "A" Missing Message Comes on Master Warning Light:
Comes on
Click here
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect Comes on Master Warning Light:
Comes on
Click here
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid Comes on Master Warning Light:
Comes on
Click here
P313487 Communication Error from Drive Motor "A" to Generator Missing Message Comes on Master Warning Light:
Comes on
Click here
P314F1F DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent Comes on Master Warning Light:
Comes on
Click here
P31531D DC/DC Converter Current Sensor Circuit Current Out of Range Does not come on Master Warning Light:
Comes on
Click here
U010087 Lost Communication With ECM/PCM "A" Missing Message Comes on Master Warning Light:
Comes on
Click here
U029387 Lost Communication With Hybrid Powertrain Control Module Missing Message Comes on Master Warning Light:
Comes on
Click here
U117087 Lost Communication With Brake System Control Module(ch2) Missing Message Does not come on Master Warning Light:
Comes on
Click here