HYBRID VEHICLE CONTROL ECU ASSEMBLY
| *A | for LHD | *B | for RHD |
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Input/Output | Condition | Specified Condition |
|---|---|---|---|---|---|
| A29-2 (R) - A30-3 (E1) | LG - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in R | 0 to 1.5 V | ||||
| A29-3 (DB1) - A30-3 (E1) | W - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-4 (HMCH) - A30-3 (E1) | B - W-B | CAN Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-5 (MREL) - A30-3 (E1) | LG - W-B | Main relay | Output | Power switch on (IG) | 11 to 14 V |
| A29-6 (HSDN) - A30-3 (E1) | G - W-B | MG ECU shutdown signal | Output | Power switch on (READY) | 0 to 1.5 V |
| A29-7 (STP) - A30-3 (E1) | G - W-B | Stop light switch | Input | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | ||||
| A29-8 (LIN3) - A30-3 (E1) | L - W-B | LIN communication signal
(A/C inverter, auxiliary battery) |
Input/Output | Power switch on (READY) | Pulse generation |
| A29-11 (+B1) - A30-3 (E1) | R - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A29-14 (HMCL) - A30-3 (E1) | W - W-B | Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-15 (DB2) - A30-3 (E1) | P - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-16 (PR) - A30-3 (E1) | R - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P or R | 0 to 1.5 V | ||||
| A29-18 (PSFT) - A30-3 (E1) | L - W-B | Shift lever position sensor power source | Output | Power switch on (ACC) | 7.5 to 14 V |
| A29-20 (BL) - A30-3 (E1) | LA-BE - W-B | Back-up light relay | Output | Power switch on (IG), shift lever in R | 11 to 14 V |
| A29-24 (VCPA) - A29-37 (EPA) | R - L | Accelerator pedal sensor assembly power source (for VPA) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-26 (VCP2) - A29-25 (EPA2) | SB - P | Accelerator pedal sensor assembly power source (for VPA2) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-28 (P) - A30-3 (E1) | BR - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P | 0 to 1.5 V | ||||
| A29-29 (N) - A30-3 (E1) | G - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in N | 7.5 to 14 V |
| Power switch on (IG), shift lever not in N | 0 to 1.5 V | ||||
| A29-30 (PNB) - A30-3 (E1) | B - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or N | 7.5 to 14 V |
| A29-33 (NIWP) - A30-3 (E1) | W - W-B | Inverter water pump assembly signal | Input | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-34 (IWP) - A30-3 (E1) | L - W-B | Inverter water pump assembly signal | Output | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-36 (VPA) - A29-37 (EPA) | G - L | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 2.6 to 4.5 V | ||||
| A29-38 (VPA2) - A29-25 (EPA2) | GR - P | Accelerator pedal sensor assembly (for accelerator pedal sensor malfunction detection) | Input | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 3.4 to 5.3 V | ||||
| A29-40 (TTA) - A29-39 (ETTA) | GR - W | Transmission fluid temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-46 (MMT) - A29-45 (MMTG) | Y - BE | Motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-48 (GMT) - A29-47 (GMTG) | G - V | Generator temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A30-1 (+B2) - A30-3 (E1) | BE - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A30-4 (ST2) - A30-3 (E1) | L - W-B | Starter signal | Input | Power switch on (IG) | 0 to 1.5 V |
| A30-7 (INDR) - A30-3 (E1) | LG - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in R | 0 to 3.2 V |
| Power switch on (IG), shift lever not in R | 11 to 14 V | ||||
| A30-8 (INDD) - A30-3 (E1) | W - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in D | 0 to 3.2 V |
| Power switch on (IG), shift lever not in D | 11 to 14 V | ||||
| A30-11 (SFTD) - A30-3 (E1) | G - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (-) or shift paddle switch LH (-) operated | 0 to 1.5 V | ||||
| A30-19 (INDP) - A30-3 (E1) | B - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in P | 0 to 3.2 V |
| Power switch on (IG), shift lever not in P | 11 to 14 V | ||||
| A30-20 (INDM) - A30-3 (E1) | LA-Y - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in S | 0 to 3.2 V |
| Power switch on (IG), shift lever not in S | 11 to 14 V | ||||
| A30-21 (INDN) - A30-3 (E1) | R - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in N | 0 to 3.2 V |
| Power switch on (IG), shift lever not in N | 11 to 14 V | ||||
| A30-24 (SFTU) - A30-3 (E1) | Y - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (+) or shift paddle switch RH (+) operated | 0 to 1.5 V | ||||
| A30-25 (M) - A30-3 (E1) | LA-B - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever not in S | 0 to 1.5 V | ||||
| A30-27 (BATT) - A30-3 (E1) | B - W-B | Constant power source | Input | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | ||||
| A30-29 (ABFS) - A30-3 (E1) | V - W-B | Airbag activation signal | Input | Power switch on (READY) | Pulse generation
(Waveform 5) |
| A30-33 (EVSW) - A30-3 (E1) | G - W-B | EV mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), EV mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| A30-37 (SPRT) - A30-3 (E1) | R - W-B | SPORT mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), SPORT mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), SPORT mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| A30-38 (NORM) ←→ A30-3 (E1) | SB - W-B | NORMAL mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), NORMAL mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), NORMAL mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| A30-44 (IGB) - A30-3 (E1) | GR - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A31-5 (ILK) - A30-3 (E1) | V - W-B | Interlock switch | Input | Power switch on (IG), service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), service plug grip not installed | 11 to 14 V | ||||
| A31-7 (CA3P) - A30-3 (E1) | G - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 8) |
| A31-8 (CA1L) - A30-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| A31-13 (SMRG) - A31-12 (E01) | G - W-B | System main relay operation signal | Output | Power switch on (IG)→Power switch on (READY) | Pulse generation
(Waveform 3) |
| A31-15 (SMRP) - A31-12 (E01) | W - W-B | System main relay operation signal | Output | Power switch on (IG)→Power switch on (READY) | Pulse generation
(Waveform 3) |
| A31-16 (SMRB) - A31-12 (E01) | GR - W-B | System main relay operation signal | Output | Power switch on (IG)→Power switch on (READY) | Pulse generation
(Waveform 3) |
| A31-20 (CA3N) - A30-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 8) |
| A31-21 (CA1H) - A30-3 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| A31-25 (PLKC) - A30-3 (E1) | BE - W-B | Shift lock release request signal | Output | Power switch on (READY), brake pedal depressed | 11 to 14 V |
| Power switch on (READY), brake pedal released | 0 to 1.5 V | ||||
| A31-28 (ST1-) - A30-3 (E1) | LA-G - W-B | Stop light switch signal | Input | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | ||||
| A31-29 (ACCI) - A30-3 (E1) | P - W-B | ACC relay | Input | Power switch on (ACC) | 11 to 14 V |
| A31-35 (IG2) - A30-3 (E1) | P - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A31-38 (SI0) - A30-3 (E1) | L - W-B | Battery cooling blower operation signal | Output | Cooling fans operating | Pulse generation
(Waveform 7) |
| Cooling fans not operating | 4.5 to 5.5 V | ||||
| A31-41 (BTH+) - A30-3 (E1) | LG - W-B | Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly | Input | Power switch on (IG) | Pulse generation
(Waveform 4) |
| A31-42 (BTH-) - A30-3 (E1) | W - W-B | Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly | Input | Power switch on (IG) | Pulse generation
(Waveform 4) |
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Input/Output | Condition | Specified Condition |
|---|---|---|---|---|---|
| A29-2 (R) - G63-3 (E1) | LG - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in R | 0 to 1.5 V | ||||
| A29-3 (DB1) - G63-3 (E1) | W - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-4 (HMCH) - G63-3 (E1) | B - W-B | CAN Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-5 (MREL) - G63-3 (E1) | W - W-B | Main relay | Output | Power switch on (IG) | 11 to 14 V |
| A29-6 (HSDN) - G63-3 (E1) | G - W-B | MG ECU shutdown signal | Output | Power switch on (READY) | 0 to 1.5 V |
| A29-7 (STP) - G63-3 (E1) | G - W-B | Stop light switch | Input | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | ||||
| A29-8 (LIN3) - G63-3 (E1) | L - W-B | LIN communication signal
(A/C inverter, auxiliary battery) |
Input/Output | Power switch on (READY) | Pulse generation |
| A29-11 (+B1) - G63-3 (E1) | R - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A29-14 (HMCL) - G63-3 (E1) | W - W-B | Communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 2) |
| A29-15 (DB2) - G63-3 (E1) | P - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or S | 7.5 to 14 V |
| Power switch on (IG), shift lever not in D or S | 0 to 1.5 V | ||||
| A29-16 (PR) - G63-3 (E1) | R - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or R | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P or R | 0 to 1.5 V | ||||
| A29-18 (PSFT) - G63-3 (E1) | L - W-B | Shift lever position sensor power source | Output | Power switch on (ACC) | 7.5 to 14 V |
| A29-20 (BL) - G63-3 (E1) | LA-BE - W-B | Back-up light relay | Output | Power switch on (IG), shift lever in R | 11 to 14 V |
| A29-24 (VCPA) - A29-37 (EPA) | R - L | Accelerator pedal sensor assembly power source (for VPA) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-26 (VCP2) - A29-25 (EPA2) | SB - P | Accelerator pedal sensor assembly power source (for VPA2) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A29-28 (P) - G63-3 (E1) | BR - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P | 7.5 to 14 V |
| Power switch on (IG), shift lever not in P | 0 to 1.5 V | ||||
| A29-29 (N) - G63-3 (E1) | G - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in N | 7.5 to 14 V |
| Power switch on (IG), shift lever not in N | 0 to 1.5 V | ||||
| A29-30 (PNB) - G63-3 (E1) | B - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or N | 7.5 to 14 V |
| A29-33 (NIWP) - G63-3 (E1) | W - W-B | Inverter water pump assembly signal | Input | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-34 (IWP) - G63-3 (E1) | L - W-B | Inverter water pump assembly signal | Output | Power switch on (READY) | Pulse generation
(Waveform 1) |
| A29-36 (VPA) - A29-37 (EPA) | G - L | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 2.6 to 4.5 V | ||||
| A29-38 (VPA2) - A29-25 (EPA2) | GR - P | Accelerator pedal sensor assembly (for accelerator pedal sensor malfunction detection) | Input | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 3.4 to 5.3 V | ||||
| A29-40 (TTA) - A29-39 (ETTA) | GR - W | Transmission fluid temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-46 (MMT) - A29-45 (MMTG) | Y - BE | Motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A29-48 (GMT) - A29-47 (GMTG) | P - V | Generator temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| G63-1 (+B2) - G63-3 (E1) | BE - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| G63-4 (ST2) - G63-3 (E1) | L - W-B | Starter signal | Input | Power switch on (IG) | 0 to 1.5 V |
| G63-7 (INDR) - G63-3 (E1) | LG - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in R | 0 to 3.2 V |
| Power switch on (IG), shift lever not in R | 11 to 14 V | ||||
| G63-8 (INDD) - G63-3 (E1) | W - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in D | 0 to 3.2 V |
| Power switch on (IG), shift lever not in D | 11 to 14 V | ||||
| G63-11 (SFTD) - G63-3 (E1) | W - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (-) or shift paddle switch LH (-) operated | 0 to 1.5 V | ||||
| G63-19 (INDP) - G63-3 (E1) | B - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in P | 0 to 3.2 V |
| Power switch on (IG), shift lever not in P | 11 to 14 V | ||||
| G63-20 (INDM) - G63-3 (E1) | LA-GR - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in S | 0 to 3.2 V |
| Power switch on (IG), shift lever not in S | 11 to 14 V | ||||
| G63-21 (INDN) - G63-3 (E1) | R - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in N | 0 to 3.2 V |
| Power switch on (IG), shift lever not in N | 11 to 14 V | ||||
| G63-24 (SFTU) - G63-3 (E1) | LG - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever in (+) or shift paddle switch RH (+) operated | 0 to 1.5 V | ||||
| G63-25 (M) - G63-3 (E1) | LA-B - W-B | Transmission control | Input | Power switch on (IG), shift lever in S | 11 to 14 V |
| Power switch on (IG), shift lever not in S | 0 to 1.5 V | ||||
| G63-27 (BATT) - G63-3 (E1) | B - W-B | Constant power source | Input | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | ||||
| G63-29 (ABFS) - G63-3 (E1) | LA-P - W-B | Airbag activation signal | Input | Power switch on (READY) | Pulse generation
(Waveform 5) |
| G63-33 (EVSW) - G63-3 (E1) | LA-G - W-B | EV mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), EV mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| G63-37 (SPRT) - G63-3 (E1) | R - W-B | SPORT mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), SPORT mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), SPORT mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| G63-38 (NORM) ←→ G63-3 (E1) | LG - W-B | NORMAL mode switch (integration control and panel assembly) signal | Input | Power switch on (IG), NORMAL mode switch (integration control and panel assembly) not operated | 11 to 14 V |
| Power switch on (IG), NORMAL mode switch (integration control and panel assembly) being pushed and held | 0 to 1.5 V | ||||
| G63-44 (IGB) - G63-3 (E1) | GR - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| G64-5 (ILK) - G63-3 (E1) | GR - W-B | Interlock switch | Input | Power switch on (IG), service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), service plug grip not installed | 11 to 14 V | ||||
| G64-7 (CA3P) - G63-3 (E1) | G - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 8) |
| G64-8 (CA1L) - G63-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| G64-13 (SMRG) - G64-12 (E01) | LA-G - W-B | System main relay operation signal | Output | Power switch on (IG)→Power switch on (READY) | Pulse generation
(Waveform 3) |
| G64-15 (SMRP) - G64-12 (E01) | LA-W - W-B | System main relay operation signal | Output | Power switch on (IG)→Power switch on (READY) | Pulse generation
(Waveform 3) |
| G64-16 (SMRB) - G64-12 (E01) | LA-GR - W-B | System main relay operation signal | Output | Power switch on (IG)→Power switch on (READY) | Pulse generation
(Waveform 3) |
| G64-20 (CA3N) - G63-3 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 8) |
| G64-21 (CA1H) - G63-3 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation
(Waveform 6) |
| G64-25 (PLKC) - G63-3 (E1) | LA-BE - W-B | Shift lock release request signal | Output | Power switch on (READY), brake pedal depressed | 11 to 14 V |
| Power switch on (READY), brake pedal released | 0 to 1.5 V | ||||
| G64-28 (ST1-) - G63-3 (E1) | LA-LG - W-B | Stop light switch signal | Input | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | ||||
| G64-29 (ACCI) - G63-3 (E1) | P - W-B | ACC relay | Input | Power switch on (ACC) | 11 to 14 V |
| G64-35 (IG2) - G63-3 (E1) | LA-B - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| G64-38 (SI0) - G63-3 (E1) | L - W-B | Battery cooling blower operation signal | Output | Cooling fans operating | Pulse generation
(Waveform 7) |
| Cooling fans not operating | 4.5 to 5.5 V | ||||
| G64-41 (BTH+) - G63-3 (E1) | LG - W-B | Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly | Input | Power switch on (IG) | Pulse generation
(Waveform 4) |
| G64-42 (BTH-) - G63-3 (E1) | W - W-B | Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly | Input | Power switch on (IG) | Pulse generation
(Waveform 4) |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (Inverter water pump assembly signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A29-34 (IWP) - A30-3 (E1) CH2: A29-33 (NIWP) - A30-3 (E1) for RHD:
CH1: A29-34 (IWP) - G63-3 (E1) CH2: A29-33 (NIWP) - G63-3 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY) |
The duty of the IWP signal and the frequency of the NIWP signal change according to the coolant (for inverter) temperature.
Waveform 2 (MG ECU communication request signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A29-4 (HMCH) - A30-3 (E1) CH2: A29-14 (HMCL) - A30-3 (E1) for RHD:
CH1: A29-4 (HMCH) - G63-3 (E1) CH2: A29-14 (HMCL) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3 (System main relay operation signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-15 (SMRP) - A31-12 (E01) CH2: A31-16 (SMRB) - A31-12 (E01) CH3: A31-13 (SMRG) - A31-12 (E01) for RHD:
CH1: G64-15 (SMRP) - G64-12 (E01) CH2: G64-16 (SMRB) - G64-12 (E01) CH3: G64-13 (SMRG) - G64-12 (E01) |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG) → Power switch on (READY) |
Waveform 4 (Communication signal from battery voltage sensor to hybrid vehicle control ECU assembly)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-41 (BTH+) - A30-3 (E1) CH2: A31-42 (BTH-) - A30-3 (E1) for RHD:
CH1: G64-41 (BTH+) - G63-3 (E1) CH2: G64-42 (BTH-) - G63-3 (E1) |
| Equipment Setting | 2 V/DIV., 500 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 5 (Airbag activation signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
A30-29 (ABFS) - A30-3 (E1) for RHD:
G63-29 (ABFS) - G63-3 (E1) |
| Equipment Setting | 5 V/DIV., 150 ms./DIV. |
| Condition | Power switch on (READY) |
Waveform 6 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-21 (CA1H) - A30-3 (E1) CH2: A31-8 (CA1L) - A30-3 (E1) for RHD:
CH1: G64-21 (CA1H) - G63-3 (E1) CH2: G64-8 (CA1L) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 7 (HV battery blower fan operation signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
A31-38 (SI0) - A30-3 (E1) for RHD:
G64-38 (SI0) - G63-3 (E1) |
| Equipment Setting | 10 V/DIV., 1 ms./DIV. |
| Condition | Cooling fans operating |
The waveform will vary with the operating speed of the battery cooling blower assembly.
Waveform 8 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | for LHD:
CH1: A31-7 (CA3P) - A30-3 (E1) CH2: A31-20 (CA3N) - A30-3 (E1) for RHD:
CH1: G64-7 (CA3P) - G63-3 (E1) CH2: G64-20 (CA3N) - G63-3 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
BATTERY VOLTAGE SENSOR
| Terminal No.
(Symbol) |
Wiring Color | Input/Output | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|---|
|
*1: for LHD *2: for RHD |
|||||
| z19-1 (TC0) - z19-7 (GC0) | G - G | Input | Intake air temperature sensor | Power switch on (IG), HV battery intake air temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z19-2 (TB2) - z19-8 (GB2) | R - R | Input | Battery temperature sensor 2 | Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z19-3 (TB1) - z19-9 (GB1) | W - W | Input | Battery temperature sensor 1 | Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z19-4 (TB0) - z19-10 (GB0) | L - L | Input | Battery temperature sensor 0 | Power switch on (IG), HV battery temperature: -40 to 90°C (-40 to 194°F) | 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F)) |
| z19-5 (IB0) - z19-12 (GIB) | G - G | Input | Battery current sensor | Power switch on (IG) | 0.5 to 4.5 V |
| z19-6 (VIB) - z19-12 (GIB) | G - G | Output | Power source for battery current sensor | Power switch on (IG) | 4.5 to 5.5 V |
| N72-1 (IGCT) - N72-5 (GND) | W - LA*1
W - W-B*2 |
Input | Control signal | Power switch on (IG) | 11 to 14 V |
| N72-2 (BTH+) - N72-5 (GND) | GR - LA*1
GR - W-B*2 |
Output | Serial communication | Power switch on (IG) | Pulse generation
(waveform 1) |
| N72-3 (BTH-) - N72-5 (GND) | W - LA*1
W - W-B*2 |
Output | Serial communication | Power switch on (IG) | Pulse generation
(waveform 2) |
| N72-5 (GND) - Body ground | LA*1
W-B*2 |
- | Ground | Always (continuity check) | Below 1 Ω |
| N72-8 (FP0) - N72-5 (GND) | B - LA*1
B - W-B*2 |
Input | Battery cooling blower monitor signal | Cooling blower stopped | 0 Hz |
| Cooling blower activated | Pulse generation
(waveform 3) |
||||
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (Serial communication)
| Item | Content |
|---|---|
| Terminal | N72-2 (BTH+) - N72-5 (GND) |
| Equipment Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 2 (Serial communication)
| Item | Content |
|---|---|
| Terminal | N72-3 (BTH-) - N72-5 (GND) |
| Equipment Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3 (Battery cooling blower monitor signal)
| Item | Content |
|---|---|
| Terminal | N72-8 (FP0) - N72-5 (GND) |
| Equipment Setting | 2 V/DIV., 2 ms/DIV. |
| Condition | Battery cooling blower assembly operating (Active Test of cooling fan being performed) |
The frequency of the waveform will vary with the operating speed of the battery cooling blower assembly.