DTC    P0112    Intake Air Temperature Circuit Low Input

DTC    P0113    Intake Air Temperature Circuit High Input

for Preparation Click here


DESCRIPTION

A067628E12
  1. The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT. The IAT sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
  2. The IAT sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
  3. Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, according to changes in the IAT, the voltage at terminal THA also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.

    HINT:
    When any of DTCs P0112 and P0113 are stored, the ECM enters fail-safe mode. During fail-safe mode, the IAT is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.


DTC No.
DTC Detection Condition
Trouble Area
P0112
Short in IAT sensor circuit for 0.5 seconds
(1 trip detection logic)
  1. Short in IAT sensor circuit
  2. IAT sensor (built into MAF meter)
  3. ECM
P0113
Open in IAT sensor circuit for 0.5 seconds
(1 trip detection logic)
  1. Open in IAT sensor circuit
  2. IAT sensor (built into MAF meter)
  3. ECM

HINT:
When any of these DTCs are stored, check the IAT by entering the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
140°C (284°F) or higher
Short circuit


MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to calculate the IAT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the IAT sensor and stores a DTC.
Example:
If the sensor output voltage is more than 4.91 V for 0.5 seconds or more, the ECM determines that there is an open in the IAT sensor circuit, and stores DTC P0113. Conversely, if the output voltage is less than 0.18 V for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and stores DTC P0112.
If the malfunction is not repaired successfully, a DTC is stored 0.5 seconds after the engine is next started.

MONITOR STRATEGY


Related DTCs
P0112: IAT sensor range check (Low voltage)
P0113: IAT sensor range check (High voltage)
Required Sensors/Components (Main)
IAT sensor
Required Sensors/Components (Related)
-
Frequency of Operation
Continuous
Duration
0.5 seconds
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
None

TYPICAL MALFUNCTION THRESHOLDS


P0112 
IAT sensor voltage [IAT]
Less than 0.18 V [More than 140°C (284°F)]

P0113 
IAT sensor voltage [IAT]
More than 4.91 V [Less than -40°C (-40°F)]

COMPONENT OPERATING RANGE


IAT sensor voltage [IAT]
0.18 to 4.91 V [-40 to 140°C (-40 to 284°F)]

WIRING DIAGRAM


A178643E01


INSPECTION PROCEDURE

HINT:
Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.READ VALUE USING TECHSTREAM (INTAKE AIR TEMPERATURE)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

  1. Read the value displayed on the Techstream.

    Standard:
    Same as actual Intake Air Temperature (IAT).

    Result 
    Result
    Proceed to
    -40°C (-40°F)
    A
    140°C (284°F) or higher
    B
    Same as actual IAT
    C

    HINT:
    1. If there is an open circuit, the Techstream indicates -40°C (-40°F).
    1. If there is a short circuit, the Techstream indicates 140°C (284°F) or higher.



B
Go to step 4

C
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


2.READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN WIRE HARNESS)
A127961E39
  1. Disconnect the MAF meter connector.

  1. Connect terminals 4 (THA) and 5 (E2) of the MAF meter wire harness side connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

  1. Read the value displayed on the Techstream.

    Standard value:
    140°C (284°F) or higher



NG
Go to step 3
OK

CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE MASS AIR FLOW METER (Click here)  

3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
A164720E19
  1. Disconnect the MAF meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    D3-4 (THA) - D56-73 (THA)
    Always
    Below 1 Ω
    D3-5 (E2) - D56-97 (ETHW)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM (Click here)  

4.READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS)
A186168E01
  1. Disconnect the MAF meter connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

  1. Read the value displayed on the Techstream.

    Standard value:
    -40°C (-40°F)



NG
Go to step 5
OK

REPLACE MASS AIR FLOW METER (Click here)  

5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
A164720E20
  1. Disconnect the MAF meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    D3-4 (THA) or D56-73 (THA) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)