DTC P0116 Engine Coolant Temperature Circuit Range / Performance Problem |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0116 | When either of following conditions met (2 trip detection logic):
|
|
| P0116 | For Mexico Models: Case 1: Engine Coolant Temperature (ECT) between 35°C and 60°C (95°F and 140°F) when engine started, and conditions (a) and (b) met (2 trip detection logic)
ECT more than 60°C (140°F) when engine started, and conditions (a) and (b) met (6 trip detection logic)
|
|
| Related DTCs | P0116: ECT sensor cold start monitor P0116: ECT sensor soak monitor |
| Required Sensors/Components (Main) | ECT sensor |
| Required Sensors/Components (Related) | Intake Air Temperature (IAT) sensor and Mass Air Flow (MAF) meter |
| Frequency of Operation | Once per driving cycle |
| Duration | 5 hours or more |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | P0110, P0112 - P0103 (IAT sensor) |
| Battery voltage | 10.5 V or more |
| Time after engine start | 1 second or more |
| ECT at engine start | Less than 60°C (140°F) |
| Soak time | 0 seconds or more |
| Accumulated MAF | 2498 g or more |
| Engine | Running |
| Fuel cut | OFF |
| Difference between ECT at engine start and IAT | Less than 40°C (72°F) |
| Monitor runs whenever following DTCs not present | P0110, P0112 - P0113 (IAT sensor) |
| Battery voltage | 10.5 V or more |
| Engine | Running |
| Soak time | 5 hours or more |
| Either (a) or (b) condition met | - |
| (a) ECT | 60°C (140°F) or more |
| (b) Accumulated MAF | 4942 g or more |
| ECT sensor value change | Less than 5°C (41°F) |
| Difference between current ECT sensor value and previous ECT sensor value when engine stopped | Less than 5°C (41°F) |
| ECT | ECT sensor value changes in accordance with actual ECT |
| 1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream ON.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTC.
| Result | Proceed to |
| P0116 | A |
| P0116 and other DTCs | B |
|
| ||||
| A | |
| 2.INSPECT THERMOSTAT |
Remove the thermostat (Click here).
Measure the valve opening temperature of the thermostat.
Reinstall the thermostat (Click here).
|
| ||||
| OK | ||
| ||