DTC P0441 Evaporative Emission Control System Incorrect Purge Flow |
| DTC No. | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P0441 | Purge VSV (Vacuum Switching Valve) stuck open | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check. If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that purge VSV stuck open. |
| While ignition switch off | 2 trip |
| Purge VSV stuck closed | After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air introduced into EVAP system. Reference pressure measured at start and at end of check. If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed. |
| While ignition switch off | 2 trip | |
| Purge flow | While engine running, following conditions successively met:
|
| While engine running | 2 trip |
| Sequence | Operation | Description | Duration |
| - | ECM activation | Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor. | 10 seconds |
| B | First reference pressure measurement | In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes* |
| D | Purge VSV monitor | Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normality. | 10 seconds |
| E | Second reference pressure measurement | After second reference pressure measurement, leak check performed by comparing first and second reference pressure. If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking. | 60 seconds |
| - | Final check | Atmospheric pressure measured and then monitoring result recorded by ECM. | - |




| Key-off Monitor |
| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 15 minutes (varies with fuel in tank) |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | P0452, P0453 (EVAP System) |
| EVAP key-off monitor runs when all of following conditions met | - |
| Atmospheric pressure | 70 to 110 kPa-a (525 to 825 mmHg-a) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 4 km/h (2.5 mph) |
| Ignition switch | off |
| Time after key off | 5 or 7 or 9.5 hours |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of following conditions met before key off | Conditions 1 and 2 |
| 1. Duration that vehicle driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
| Purge VSV stuck open: | - |
| EVAP pressure when vacuum introduction complete | Reference pressure x 0.2 or higher |
| Purge VSV stuck closed: | - |
| EVAP pressure change after purge VSV ON (open) | Less than 0.3 kPa-g (2.25 mmHg-g) |
| Purge Flow Monitor |
| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 10 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | P0452, P0453 (EVAP System) |
| Engine | Running |
| ECT | 4.4°C (40°F) or more |
| IAT | 4.4°C (40°F) or more |
| Purge VSV | Not operated by scan tool |
| EVAP system check | Not operated by scan tool |
| Battery voltage | 10 V or more |
| Purge duty cycle | 8% or more |
| Both of following conditions met | Conditions 1 and 2 |
| 1. EVAP pressure change when purge operation started | Less than 0.1 kPa-g (0.75 mmHg-g) |
| 2. EVAP pressure change during purge operation when vent valve closed | Less than 0.4 kPa-g (3 mmHg-g) |