Home › Engine / Hybrid System ยท 3UR-FBE › ENGINE CONTROL › SFI SYSTEM

DTC    P0455    Evaporative Emission Control System Leak Detected (Gross Leak)

DTC    P0456    Evaporative Emission Control System Leak Detected (Very Small Leak)

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P0455
EVAP gross leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that EVAP system has large leak.
  1. Fuel tank cap (loose)
  2. Leak from EVAP line
    (Canister - Fuel tank)
  3. Leak from EVAP line
    (Purge VSV - Canister)
  4. Canister pump module
  5. Leak from fuel tank
  6. Leak from canister
While ignition switch off
2 trip
P0456
EVAP small leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than second reference pressure, ECM determines that EVAP system has small leak.
  1. Fuel tank cap (loose)
  2. Leak from EVAP line
    (Canister - Fuel tank)
  3. Leak from EVAP line
    (Purge VSV - Canister)
  4. Canister pump module
  5. Leak from fuel tank
  6. Leak from canister
While ignition switch off
2 trip

DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
10 seconds
B
First reference pressure measurement
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normality.
10 seconds
E
Second reference pressure measurement
After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
-
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E14

  1. (a) P0455: EVAP gross leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second reference pressure x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leak, illuminates the MIL and stores the DTC (2 trip detection logic).

  2. (b) P0456: EVAP very small leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than the second reference pressure, the ECM determines that the EVAP system has a small leak, illuminates the MIL and stores the DTC (2 trip detection logic).


    A164985E03


MONITOR STRATEGY


Required Sensors/Components
Purge VSV and canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
P0452, P0453 (EVAP System)

P0455 (Pattern 1), P0456 
Atmospheric pressure
70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage
10.5 V or more
Vehicle speed
Below 4 km/h (2.5 mph)
Ignition switch
off
Time after key off
5 or 7 or 9.5 hours
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before key off
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. EVAP purge operation
Performed
ECT
4.4 to 35°C (40 to 95°F)
IAT
4.4 to 35°C (40 to 95°F)

P0455 (Pattern 2) 
Atmospheric pressure
70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage
10.5 V or more
Vehicle speed
Below 4 km/h (2.5 mph)
Ignition switch
off
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of the following conditions 1 and 2 set before key off
-
1. Duration that vehicle has been driven
5 minutes or more
2. EVAP purge operation
Performed
ECT
4.4 to 40°C (40 to 104°F)
IAT
4.4 to 40°C (40 to 104°F)

TYPICAL MALFUNCTION THRESHOLDS


P0455 (Pattern 1) 
EVAP pressure when vacuum introduction complete
Higher than reference pressure x 0.2

P0455 (Pattern 2) 
EVAP pressure when vacuum introduction complete
Higher than reference pressure x 0.2

P0456 
EVAP pressure when vacuum introduction complete
Between reference pressure and reference pressure x 0.2

MONITOR RESULT

Refer to Checking Monitor Status (Click here).