Home › Engine / Hybrid System · 3UR-FBE › ENGINE CONTROL › SFI SYSTEM

DTC    P0451    Evaporative Emission Control System Pressure Sensor Range / Performance

DTC    P0452    Evaporative Emission Control System Pressure Sensor / Switch Low Input

DTC    P0453    Evaporative Emission Control System Pressure Sensor / Switch High Input

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P0451
Canister pressure sensor noise
Sensor output voltage fluctuates frequently within certain time period.
  1. Canister pump module
  2. Connector/wire harness
    (Canister pump module - ECM)
  3. EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
  4. ECM
  1. EVAP monitoring (ignition switch off)
  2. Engine running
2 trip
Canister pressure sensor signal becomes fixed/flat
Sensor output voltage does not vary within certain time period.
  1. Canister pump module
  2. Connector/wire harness
    (Canister pump module - ECM)
  3. EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
  4. ECM
  1. EVAP monitoring (ignition switch off)
2 trip
P0452
Canister pressure sensor low input
EVAP pressure less than 42.1 kPa for 0.5 seconds.
  1. Canister pump module
  2. Connector/wire harness
    (Canister pump module - ECM)
  3. EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
  4. ECM
  1. Ignition switch ON
  2. EVAP monitoring (ignition switch off)
1 trip
P0453
Canister pressure sensor high input
EVAP pressure more than 123.8 kPa for 0.5 seconds.
  1. Canister pump module
  2. Connector/wire harness
    (Canister pump module - ECM)
  3. EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
  4. ECM
  1. Ignition switch ON
  2. EVAP monitoring (ignition switch off)
1 trip

HINT:
The canister pressure sensor is built into the canister pump module.


DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System .

MONITOR DESCRIPTION


A115543E25

  1. DTC P0451: Canister pressure sensor noise or fixed/flat
    If the canister pressure sensor voltage output fluctuates rapidly for 10 seconds, the ECM stops the EVAP system monitor. The ECM interprets this as noise from the canister pressure sensor, and stops the EVAP system monitor. The ECM then illuminates the MIL and stores the DTC.
    Alternatively, if the sensor voltage output does not change for 10 seconds, the ECM interprets this as the sensor being fixed/flat, and stops the monitor. The ECM then illuminates the MIL and stores the DTC.
    (Both malfunctions are detected by 2 trip detection logic.)
  2. DTC P0452: Canister pressure sensor voltage low
    If the canister pressure sensor output [pressure] is below 42.1 kPa-a (315.9 mmHg-a), the ECM interprets this as an open or short circuit malfunction in the canister pressure sensor or its circuit, and stops the EVAP system monitor. The ECM then illuminates the MIL and stores the DTC (1 trip detection logic).
  3. DTC P0453: Canister pressure sensor voltage high
    If the canister pressure sensor output [pressure] is 123.8 kPa-a (928.4 mmHg-a) or more, the ECM interprets this as an open or short circuit malfunction in the canister pressure sensor or its circuit, and stops the EVAP system monitor. The ECM then illuminates the MIL and stores the DTC (1 trip detection logic).

MONITOR STRATEGY


Required Sensors/Components
Canister pump module
Frequency of Operation
Once per driving cycle: P0451 sensor fixed/flat
Continuous: P0451 sensor noise, P0452 and P0453
Duration
0.5 seconds: P0452 and P0453
2 minutes: P0451
MIL Operation
Immediate: P0452 and P0453
2 driving cycles: P0451
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


P0451 (Noise Monitor) 
Monitor runs whenever following DTCs not present
P0452, P0453 (EVAP System)
Atmospheric pressure (absolute pressure)
70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage
10.5 V or more
Intake air temperature
4.4 to 35°C (40 to 95°F)
Either of following conditions met
A or B
A. Engine condition
Running
B. Time after key off
5 or 7 or 9.5 hours

P0451 (Fixed/Flat Monitor) 
Monitor runs whenever following DTCs not present
P0452, P0453 (EVAP System)
Battery voltage
10.5 V or more
Intake air temperature
4.4 to 35°C (40 to 95°F)
Atmospheric pressure (absolute pressure)
Less than 70 kPa-a (525 mmHg-a) or 110 kPa-a (825 mmHg-a) or more
Time after key off
5 or 7 or 9.5 hours

P0452 and P0453 
Monitor runs whenever following DTCs not present
None
Either of following conditions met
(a) or (b)
(a) Ignition switch
ON
(b) Soak timer
ON

TYPICAL MALFUNCTION THRESHOLDS


P0451: Canister Pressure Sensor Noise 
Frequency that EVAP pressure change 0.3 kPa-g (2.25 mmHg-g) or more
10 times or more in 10 seconds

P0451: Canister Pressure Sensor Fixed/Flat 
EVAP pressure change during reference pressure
Less than 0.65 kPa-g (4.87 mmHg-g)

P0452: Canister Pressure Sensor Low Voltage 
EVAP pressure
Less than 42.1 kPa-a (315.9 mmHg-a)

P0453: Canister Pressure Sensor High Voltage 
EVAP pressure
More than 123.8 kPa-a (928.4 mmHg-a)

WIRING DIAGRAM


A164731E06


INSPECTION PROCEDURE

NOTICE:
  1. When a vehicle is brought into the workshop, leave it as it is. Do not change the vehicle condition. For example, do not tighten the fuel cap.
  2. Do not disassemble the canister pump module.
  3. The Techstream is required to conduct the following diagnostic troubleshooting procedure.

1.CONFIRM DTC AND EVAP PRESSURE
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (do not start the engine).

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read DTCs.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / EVAP / Vapor Pressure Pump.

  1. Read the EVAP (Evaporative Emission) pressure displayed on the Techstream.

    Result 
    Result
    Test Result
    Suspected Trouble Area
    Proceed to
    P0451
    -
    Canister pressure sensor
    C
    P0452
    Less than 45 kPa-a (430 mmHg-a)
    1. Wire harness/connector (ECM - Canister pressure sensor)
    2. Canister pressure sensor
    3. Short in ECM circuit
    A
    P0453
    More than 120 kPa-a (900 mmHg-a)
    1. Wire harness/connector (ECM - Canister pressure sensor)
    2. Canister pressure sensor
    3. Open in ECM circuit
    B



B
Go to step 4

C
GO TO EVAP SYSTEM (Click here)
A


2.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
A136305E61
  1. Turn the ignition switch off.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Result 
    Tester Connection
    Condition
    Specified Condition
    Suspected Trouble Area
    Proceed to
    D56-121 (PPMP) - Body ground
    Always
    10 Ω or less
    1. Wire harness/connector (ECM - Canister pressure sensor)
    2. Short in canister pressure sensor circuit
    A
    D56-121 (PPMP) - Body ground
    Always
    10 kΩ or more
    1. Wire harness/connector (ECM - Canister pressure sensor)
    2. Short in ECM circuit
    B



B
Go to step 7
A


3.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
A185026E02
  1. Disconnect the canister pump module connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Result 
    Tester Connection
    Condition
    Specified Condition
    Suspected Trouble Area
    Proceed to
    D56-121 (PPMP) - Body ground
    Always
    10 kΩ or more
    Short in canister pressure sensor circuit
    A
    D56-121 (PPMP) - Body ground
    Always
    10 Ω or less
    Short in wire harness/connector (ECM - Canister pressure sensor)
    B



A
Go to step 5

B
Go to step 6

4.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
A185025E01
  1. Disconnect the canister pump module connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O24-2 (SGND) - Body ground
    Always
    100 Ω or less

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    O24-4 (VCC) - Body ground
    Ignition switch ON
    4.5 to 5.5 V
    O24-3 (VOUT) - Body ground
    Ignition switch ON
    4.5 to 5.5 V


Result 
Result
Suspected Trouble Area
Proceed to
Voltage and resistance within standard ranges
Open in canister pressure sensor circuit
A
Voltage and resistance outside standard ranges
Open in wire harness/connector (ECM - Canister pressure sensor)
B


B
Go to step 6
A


5.REPLACE CHARCOAL CANISTER ASSEMBLY


  1. Replace the canister assembly (Click here).

    NOTICE:
    When replacing the canister, check the canister pump module interior and related pipes for water, fuel and other liquids. If liquids are present, check for disconnections and/or cracks in the following: 1) the pipe from the air inlet port to the canister pump module; 2) the canister filter; and 3) the fuel tank vent hose.


    A195091E01



NEXT
Go to step 8

6.REPAIR OR REPLACE HARNESS OR CONNECTOR (CANISTER PUMP MODULE - ECM)

HINT:
If the exhaust tailpipe has been removed, go to the next step before reinstalling it.



NEXT
Go to step 8

7.REPLACE ECM
  1. Replace the ECM (Click here).


NEXT


8.CHECK WHETHER DTC OUTPUT RECURS (AFTER REPAIR)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Wait for at least 60 seconds.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes / Pending.

HINT:
If no pending DTCs are displayed on the Techstream, the repair has been successfully completed.


NEXT

END