COMPRESSOR (for 2UZ-FE) > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
![]() |
When replacing the compressor with a new one, gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new compressor before installation, so that the amount of oil contained in it is the same as that in the compressor to be replaced.
| 2. INSTALL COOLER COMPRESSOR ASSEMBLY |
![]() |
Install the cooler compressor and No. 1 compressor stay with the 3 bolts and nut.
| 3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the attached vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring on the cooler refrigerant discharge hose.
Connect the cooler refrigerant discharge hose on the cooler compressor with the bolt.
| 4. CONNECT NO. 1 COOLER REFRIGERANT SUCTION HOSE |
![]() |
Remove the attached vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring on the cooler refrigerant suction hose.
Connect the cooler refrigerant suction hose on the cooler compressor with the bolt.
| 5. INSTALL FENDER APRON MUDGUARD SEAL LH |
![]() |
Install the seal with the 6 clips.
| 6. INSTALL FAN AND GENERATOR V BELT |
Install the fan and generator V belt (Click here).
| 7. CHARGE REFRIGERANT |

Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

Install the caps onto the service valves on the refrigerant line.
| 8. WARM UP ENGINE |
| 9. INSPECT FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
![]() |
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.