Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR

SOLAR SENSOR > INSPECTION

for Preparation Click here



1. INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)


B109993E54
  1. Remove the solar sensor with the connector still connected.

  1. Apply battery voltage between terminals 6 (CLTB) and 3 (CLTE) of the A/C solar sensor.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1 (TSL) - 3 (CLTE)
    Sensor subject to electric light
    0.8 to 4.3 V
    1 (TSL) - 3 (CLTE)
    Sensor covered with a cloth
    Below 0.8 V
    2 (TSR) - 3 (CLTE)
    Sensor subject to electric light
    0.8 to 4.3 V
    2 (TSR) - 3 (CLTE)
    Sensor covered with a cloth
    Below 0.8 V

    If the result is not as specified, replace the solar sensor.

    HINT:
    1. As the inspection light is moved away from the sensor, the voltage increases.
    2. Use an incandescent lamp for inspection. Bring it within 30 cm (11.8 in.) of the solar sensor.