ENGINE IMMOBILISER SYSTEM > ECU Power Source Circuit |

| 1.INSPECT FUSES (IMB, IGN) |
Remove the IMB fuse and IGN fuses from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| IMB fuse | Always | Below 1 Ω |
| IGN fuse |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSPONDER KEY ECU - BATTERY AND BODY GROUND) |
![]() |
Disconnect the H32 ECU connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H32-16 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| H32-1 (+B) - Body ground | Always | 11 to 14 V |
| H32-2 (IG) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V |
Reconnect the ECU connector.
|
| ||||
| OK | ||
| ||