CAN COMMUNICATION SYSTEM > Distance Control ECU Communication Stop Mode |
| Detection Item | Symptom | Trouble Area |
| Combination Meter ECU Communication Stop Mode | When either condition below is met:
|
|

| 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
| NEXT | |
| 2.CHECK FOR OPEN IN CAN BUS WIRE (DISTANCE CONTROL ECU BRANCH WIRE) |
![]() |
Disconnect the A43 distance control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A43-8 (CANH) - A43-9 (CANL) | Ignition switch off | 54 to 69 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (DISTANCE CONTROL ECU - BATTERY AND BODY GROUND) |
![]() |
Reconnect the cable to the negative (-) battery terminal.
Disconnect the A43 distance control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A43-12 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A43-1 (B) - Body ground | Ignition switch ON | 11 to 14 V |
|
| ||||
| OK | ||
| ||