METER / GAUGE SYSTEM > FAIL-SAFE CHART |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Vehicle speed pulse is interrupted | Controls input signals as 0 km/h (0 mph) | Normal data is received |
| Vehicle speed signal is interrupted for 0.12 seconds | Controls input signals as 0 km/h (0 mph) | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, vehicle speed pulse signal integration value is interrupted for 0.12 seconds | Data received most recently remains displayed | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Engine revolution signal is interrupted for 0.12 seconds | Controls input signals as 0 rpm | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, engine coolant temperature data is interrupted for 3.1 seconds | Gauge needle indicates below "C" | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, sender signal is interrupted for 60 seconds and malfunction signal is received from one of gauges for 10 to 20 seconds | Needle indicates "E", and warning light comes on | Ignition switch is turned from OFF to ON and normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Default control | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| EEPROM cannot determine constant value due to EEPROM reading malfunction or other malfunction | Gauge needle does not move | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, A/T oil temperature data is interrupted for 3.1 seconds | Gauge needle indicates below "C" | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| "P to D" data is interrupted | All data cannot be displayed: Shift position indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Gear position signal is interrupted | Data received most recently remains displayed (when data is interrupted for 3.1 seconds, shift position indicator goes off) | Normal data is received |
| Sequential mode indicator and sequential mode enable signals are interrupted | Data received most recently remains displayed (when data is interrupted for 3.1 seconds, shift position indicator goes off) | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Headlight HI on instruction signal is interrupted for 10 seconds during CAN bus wake-up mode |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Headlight LO on request signal is interrupted for 10 seconds during CAN bus wake-up mode |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Taillight on request signal is interrupted for 10 seconds during CAN bus wake-up mode |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, ABS warning light signal is interrupted for 1 second | ABS warning light remains on until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, brake warning light signal is interrupted for 1 second | Brake warning light condition is maintained until ignition switch off | Normal data is received |
| Parking brake switch signal is interrupted for 10 seconds during CAN bus wake-up mode |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Height control indicator light signal is interrupted | Height control indicator light condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, frame (including B IND4WD bit) is interrupted for 3 seconds | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, frame (including B INDL4 bit) is interrupted for 3 seconds | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, frame (including B INDDL bit) is interrupted for 3 seconds | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, frame (including B ALSD bit) is interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, SRS warning light on/blink request signal (9.0 V or higher) is interrupted for 10 seconds, or SRS warning light on/blink request signal (below 9 V) is interrupted for 60 seconds | SRS warning light remains on until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, A/T OIL TEMP warning signals are interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, CHARGE warning signals are interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Driver side seat belt buckle switch signal is interrupted for 10 seconds during CAN bus wake-up mode |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Driver side courtesy switch, front passenger side courtesy switch, rear door LH courtesy switch, rear door RH courtesy switch and back door courtesy switch signals are interrupted for 10 seconds during CAN bus wake-up mode |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Frame data (including SLIP indicator on/blink request signal) is interrupted | SLIP indicator light condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, VSC OFF indicator light signal is interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, tire pressure warning signals are interrupted |
| Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While ignition switch is ON, washer fluid level low signals are interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| CRUISE main indicator light signal is interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| TOW HAUL Indicator Light signal is interrupted | Display condition is maintained until ignition switch off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| When the odometer reading upon reset cannot be determined | Control assuming odometer display of 0 upon reset | Normal data is received |
| When the current odometer reading cannot be determined | The indicator is turned on | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| EPS warning Light signal is interrupted | Display condition is maintained until ignition switch off | Normal data is received |