SHIFT LEVER > INSPECTION |
| 1. INSPECT SHIFT LOCK CONTROL ECU |
![]() |
Measure the voltage according to the values in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 12 (IG) - 3 (E) | Ignition switch ON | 11 to 14 V |
| 12 (IG) - 3 (E) | Ignition switch off | Below 1 V |
| 6 (STP) - 3 (E) | Depress brake pedal | 11 to 14 V |
| 6 (STP) - 3 (E) | Release brake pedal | Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 8 (E) - Body ground | When battery voltage not applied | Below 1 Ω |
![]() |
Disconnect the shift lock solenoid connector from the shift lock control ECU.
Measure the voltage according to the values in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (SLS+) - 2 (SLS-) | Ignition switch off | Below 1 V |
| 1 (SLS+) - 2 (SLS-) | Ignition switch ON | Below 1 V |
| 1 (SLS+) - 2 (SLS-) | Ignition switch ON and brake pedal depressed | 11 to 14 V |
| 2. INSPECT SHIFT LOCK SOLENOID |
![]() |
Disconnect the shift lock solenoid connector from the shift lock control ECU.
Measure the resistance according to the values in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (SLS+) - 2 (SLS-) | When battery voltage not applied | 101 to 123 Ω |
| 3 (E2) - 4 (P) | Shift position P | 10 kΩ or higher |
| 3 (E2) - 4 (P) | Shift position not P | Below 1 Ω |
Apply 12 V battery voltage to the shift lock solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 1 (SLS+) Battery negative (-) → Terminal 2 (SLS-) | Solenoid moves and makes an operating noise |
| 3. INSPECT TRANSMISSION CONTROL SWITCH |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (IG) - 7 (S) | Shift position S | Below 1 Ω |
| 3 (IG) - 7 (S) | Shift position not S | 10 kΩ or higher |
| 2 (SFTU) - 5 (E) | Shift lever continuously shifted to "+" position (Up-shift) | Below 1 Ω |
| 2 (SFTU) - 5 (E) | Shift position S | 10 kΩ or higher |
| 1 (SFTD) - 5 (E) | Shift lever continuously shifted to "-" position (Down-shift) | Below 1 Ω |
| 1 (SFTD) - 5 (E) | Shift position S | 10 kΩ or higher |